International Multi-institutional Patterns of Contouring Practice and Clinical Target Volume Recommendations for Stereotactic Body Radiation Therapy for Non-Spine Bone Metastases

被引:22
作者
Nguyen, Timothy K. [1 ]
Chin, Lee [2 ]
Sahgal, Arjun [2 ]
Dagan, Roi [3 ]
Eppinga, Wietse [4 ]
Guckenberger, Matthias [5 ]
Kim, Jin Ho [6 ]
Lo, Simon S. [7 ]
Redmond, Kristin J. [8 ]
Siva, Shankar [9 ]
Stish, Bradley J. [10 ]
Chan, Rachel [11 ]
Lawrence, Liam [12 ]
Lau, Angus [11 ,12 ]
Tseng, Chia-Lin [2 ]
机构
[1] Western Univ, London Hlth Sci Ctr, Schulich Sch Med & Dent, Dept Radiat Oncol, London, ON, Canada
[2] Univ Toronto, Odette Canc Ctr, Sunnybrook Hlth Sci Ctr, Dept Radiat Oncol, Toronto, ON, Canada
[3] Univ Florida, Hlth Proton Therapy Inst, Dept Radiat Oncol, Jacksonville, FL USA
[4] Univ Med Ctr, Dept Radiat Oncol, Utrecht, Netherlands
[5] Univ Zurich, Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[6] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul, South Korea
[7] Univ Washington, Dept Radiat Oncol, Seattle, WA 98195 USA
[8] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD USA
[9] Univ Melbourne, Peter MacCallum Canc Ctr, Sir Peter MacCallum Dept Oncol, Melbourne, Vic, Australia
[10] Mayo Clin, Dept Radiat Oncol, Rochester, MN USA
[11] Sunnybrook Res Inst, Dept Phys Sci, Toronto, ON, Canada
[12] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2022年 / 112卷 / 02期
关键词
CONSENSUS GUIDELINES; RADIOTHERAPY; RADIOSURGERY; DELINEATION; FRACTIONS; OUTCOMES; SINGLE;
D O I
10.1016/j.ijrobp.2021.09.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Despite the increasing use of stereotactic body radiation therapy for non-spine bone metastases (NSBM), there is no established standard for target delineation. The objective of this study was to provide consensus recommendations on clinical target volume (CTV) delineation based on international expert contours. Methods and Materials: Eleven cases of NSBM were contoured by 9 international radiation oncologists. For each case, the gross tumor volume was provided on the simulation computed tomography scans with accompanying magnetic resonance imaging. Participants contoured the CTV and completed a clinical survey. Agreement between CTV contours were analyzed with simultaneous truth and performance level estimation using the kappa coefficient and the Dice similarity coefficient (DSC) and summarized to establish contouring recommendations. A direction-dependent analysis was applied to the consensus contours to quantify margins. Results: All CTV contours were completed. Six participants used a single-dose level, whereas 3 used a 2-dose level simultaneous integrated boost (SIB) technique. For the SIB cases, the largest volume receiving a stereotactic body radiation therapy (SBRT) dose was used for contour analysis. There was substantial agreement between contours across cases with a mean kappa of 0.72 (mean sensitivity 0.85, mean specificity 0.97). The mean DSC value was 0.77 (range, 0.67-0.87). Consensus CTV contouring recommendations were (1) an intraosseous CTV margin of 5 to 10 mm should be strongly considered within contiguous bone; (2) an extraosseous margin of 5 to 10 mm should be strongly considered where there is soft tissue disease or cortical bone disruption; (3) CTVs should be manually cropped to respect anatomic barriers to spread (eg, peritoneal cavity, pleura, uninvolved joint space and cortical bone). Conclusions: CTV contouring recommendations for NSBM-SBRT were established based on analysis of international expert consensus contours with a high level of agreement. These principles may provide guidance to treating physicians and inform future study until prospective clinical data can provide further refinement. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:351 / 360
页数:10
相关论文
共 32 条
[1]  
Cao Yilin, 2021, J Radiosurg SBRT, V7, P199
[2]   Phase I/II study of stereotactic body radiotherapy for spinal metastasis and its pattern of failure [J].
Chang, Eric L. ;
Shiu, Almon S. ;
Mendel, Ehud ;
Mathews, Leni A. ;
Mahajan, Anita ;
Allen, Pamela K. ;
Weinberg, Jeffrey S. ;
Brown, Barry W. ;
Wang, Xin Shelly ;
Woo, Shiao Y. ;
Cleeland, Charles ;
Maor, Moshe H. ;
Rhines, Laurence D. .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (02) :151-160
[3]   Evaluation of Safety of Stereotactic Body Radiotherapy for the Treatment of Patients With Multiple Metastases Findings From the NRG-BR001 Phase 1 Trial [J].
Chmura, Steve ;
Winter, Kathryn A. ;
Robinson, Clifford ;
Pisansky, Thomas M. ;
Borges, Virginia ;
Al-Hallaq, Hania ;
Matuszak, Martha ;
Park, Sean S. ;
Yi, Sun ;
Hasan, Yasmin ;
Bazan, Jose ;
Wong, Philip ;
Yoon, Harold A. ;
Horton, Janet ;
Gan, Gregory ;
Milano, Michael T. ;
Sigurdson, Elin Ruth ;
Moughan, Jennifer ;
Salama, Joseph K. ;
White, Julia .
JAMA ONCOLOGY, 2021, 7 (06) :845-852
[4]   Palliative radiotherapy trials for bone metastases: A systematic review [J].
Chow, Edward ;
Harris, Kristin ;
Fan, Grace ;
Tsao, May ;
Sze, Wai M. .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (11) :1423-1436
[5]   Single versus multiple fractions of repeat radiation for painful bone metastases: a randomised, controlled, non-inferiority trial [J].
Chow, Edward ;
van der Linden, Yvette M. ;
Roos, Daniel ;
Hartsell, William F. ;
Hoskin, Peter ;
Wu, Jackson S. Y. ;
Brundage, Michael D. ;
Nabid, Abdenour ;
Tissing-Tan, Caroline J. A. ;
Oei, Bing ;
Babington, Scott ;
Demas, William F. ;
Wilson, Carolyn F. ;
Meyer, Ralph M. ;
Chen, Bingshu E. ;
Wong, Rebecca K. S. .
LANCET ONCOLOGY, 2014, 15 (02) :164-171
[6]   International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery [J].
Cox, Brett W. ;
Spratt, Daniel E. ;
Lovelock, Michael ;
Bilsky, Mark H. ;
Lis, Eric ;
Ryu, Samuel ;
Sheehan, Jason ;
Gerszten, Peter C. ;
Chang, Eric ;
Gibbs, Iris ;
Soltys, Scott ;
Sahgal, Arjun ;
Deasy, Joe ;
Flickinger, John ;
Quader, Mubina ;
Mindea, Stefan ;
Yamada, Yoshiya .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (05) :E597-E605
[7]   International consensus recommendations for target volume delineation specific to sacral metastases and spinal stereotactic body radiation therapy (SBRT) [J].
Dunne, Emma M. ;
Sahgal, Arjun ;
Lo, Simon S. ;
Bergman, Alanah ;
Kosztyla, Robert ;
Dea, Nicolas ;
Chang, Eric L. ;
Chang, Ung-Kyu ;
Chao, Samuel T. ;
Faruqi, Salman ;
Ghia, Amol J. ;
Redmond, Kristin J. ;
Soltys, Scott G. ;
Liu, Mitchell C. .
RADIOTHERAPY AND ONCOLOGY, 2020, 145 :21-29
[8]   Local control and fracture risk following stereotactic body radiation therapy for non-spine bone metastases [J].
Erler, Darby ;
Brotherston, Drew ;
Sahgal, Arjun ;
Cheung, Patrick ;
Loblaw, Andrew ;
Chu, William ;
Soliman, Hany ;
Chung, Hans ;
Kiss, Alex ;
Chow, Edward ;
Poon, Ian .
RADIOTHERAPY AND ONCOLOGY, 2018, 127 (02) :304-309
[9]   Inter-observer agreement in GTV delineation of bone metastases on CT and impact of MR imaging: A multicenter study [J].
Gerlich, A. S. ;
van der Velden, J. M. ;
Kotte, A. N. T. J. ;
Tseng, C. L. ;
Fanetti, G. ;
Eppinga, W. S. C. ;
Kasperts, N. ;
Intven, M. P. W. ;
Pameijer, F. A. ;
Philippens, M. E. P. ;
Verkooijen, H. M. ;
Seravalli, E. .
RADIOTHERAPY AND ONCOLOGY, 2018, 126 (03) :534-540
[10]   Radiosurgery for spinal metastases - Clinical experience in 500 cases from a single institution [J].
Gerszten, Peter C. ;
Burton, Steven A. ;
Ozhasoglu, Cihat ;
Welch, William C. .
SPINE, 2007, 32 (02) :193-199