Titanium and Platinum-Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography

被引:2
作者
Dahm, Valerie [1 ]
Schwarz-Nemec, Ursula [2 ]
Auinger, Alice B. [1 ]
Arnoldner, Michael A. [2 ]
Kaider, Alexandra [3 ]
Riss, Dominik [1 ]
Czerny, Christian [2 ]
Arnoldner, Christoph [1 ]
机构
[1] Med Univ Vienna, Dept Otorhinolaryngol Head & Neck Surg, A-1090 Vienna, Austria
[2] Med Univ Vienna, Div Neuroradiol & Musculoskeletal Radiol, Dept Radiol, A-1090 Vienna, Austria
[3] Med Univ Vienna, Ctr Med Stat Informat & Intelligent Syst, A-1090 Vienna, Austria
来源
LIFE-BASEL | 2021年 / 11卷 / 02期
关键词
stapedotomy; piston; computed tomography; cone beam computed tomography;
D O I
10.3390/life11020156
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: The aim of this study was to evaluate whether stapes prostheses can be visualized with less metal artifacts and therefore more accurately on cone beam computed tomography in comparison to computed tomography imaging. Recent studies have shown that cone beam computed tomography has advantages when imaging metal artifacts. Patients with hearing loss or vertigo, who have undergone stapedotomy, often present a challenge for otologic surgeons. Imaging studies can deliver crucial additional information. Methods: A retrospective analysis of imaging studies and clinical data in a tertiary care center were carried out. Forty-one patients with forty-five implanted ears were evaluated in the study. All included patients had been implanted with a platinum-fluoroplastic (n = 19) or titanium (n = 26) piston and subsequently had undergone imaging months or years after surgery for various reasons. Patients underwent computed tomography or cone beam computed tomography of the temporal bone depending on availability. Piston visualization, prosthesis length, vestibular intrusion and audiologic results were compared between the groups. Piston position on imaging studies were compared to intraoperative findings. Results: Functional length measurements of all prostheses were carried out with a mean error of -0.17 mm (+/- 0.20). Platinum-fluoroplastic protheses were significantly underestimated in length compared to titanium prostheses. To analyze the material-dependent difference in the measurement errors of the imaging techniques the interaction was tested in an ANOVA model and showed no statistically significant result (p = 0.24). The blinded neuroradiologist viewed two implants, both platinum-fluoroplastic pistons, as located outside of the vestibule due to an underestimation of the prothesis length and the missing radiodensity of the lower end of the prosthesis. Conclusion: Surgeons and radiologists should be aware of the different types and radiologic features of stapes prostheses and the missing radiodensity of some protheses parts. Cone beam computed tomography is an imaging alternative with a potential advantage of reduced radiation in patients after stapes surgery suffering from vertigo or hearing loss to evaluate piston position.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 18 条
  • [1] Quality control after cochlear implant surgery by means of rotational tomography
    Aschendorff, A
    Kubalek, T
    Turowski, B
    Zanella, T
    Hochmuth, T
    Schumacher, T
    Klenzner, T
    Laszig, R
    [J]. OTOLOGY & NEUROTOLOGY, 2005, 26 (01) : 34 - 37
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses
    Bozzato, Alessandro
    Struffert, Tobias
    Hertel, Victoria
    Iro, Heinrich
    Hornung, Joachim
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (03) : 566 - 571
  • [4] Bremke M, 2013, OTOL NEUROTOL, V34, P1321, DOI 10.1097/MAO.0b013e31828bb73c
  • [5] Casale M, 2003, Rev Laryngol Otol Rhinol (Bord), V124, P255
  • [6] Use of 3D Volume Rendering Based on High-Resolution Computed Tomography Temporal Bone in Patients with Cochlear Implants
    Ciodaro, Francesco
    Freni, Francesco
    Mannetta, Valentina Katia
    Gazia, Francesco
    Maceri, Annunziata
    Bruno, Rocco
    Galletti, Bruno
    Galletti, Francesco
    [J]. AMERICAN JOURNAL OF CASE REPORTS, 2019, 20 : 184 - 188
  • [7] Digital volume tomography: Radiologic examinations of the temporal bone
    Dalchow, CV
    Weber, AL
    Yanagihara, N
    Bien, S
    Werner, JA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (02) : 416 - 423
  • [8] MPR-CT Imaging for Stapes Prosthesis: Accuracy and Clinical Significance
    Fang, Yanqing
    Wang, Bing
    Galvin, John J.
    Tao, Duoduo
    Deng, Rui
    Ou, Xiong
    Liu, Yangwenyi
    Dai, Peidong
    Sha, Yan
    Zhang, Tianyu
    Chen, Bing
    [J]. OTOLOGY & NEUROTOLOGY, 2016, 37 (04) : 321 - 323
  • [9] Three-dimensional reconstruction of the temporal bone: Comparison of in situ, CT, and CBCT measurements
    Guyader, E.
    Savean, J.
    Clodic, C.
    Letellier, P.
    Meriot, P.
    Marianowski, R.
    [J]. EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2018, 135 (06) : 393 - 398
  • [10] Assessing Stapes Piston Position Using Computed Tomography: A Cadaveric Study
    Hahn, Yoav
    Diaz, Rodney
    Hartman, Jonathan
    Bobinski, Matthew
    Brodie, Hilary
    [J]. OTOLOGY & NEUROTOLOGY, 2009, 30 (02) : 223 - 230