Real-time MRI-guided needle intervention for cryoablation: A phantom study

被引:0
作者
Gao, Wenpeng [1 ]
Jiang, Baichuan [2 ]
Kacher, Dan F. [3 ]
Fetics, Barry [4 ]
Nevo, Erez [4 ]
Lee, Thomas C. [5 ]
Jayender, Jagadeesan [4 ]
机构
[1] Harbin Inst Technol, Sch Life Sci & Technol, Harbin, Peoples R China
[2] Tianjin Univ, Dept Mech Engn, Tianjin, Peoples R China
[3] Brigham & Womens Hosp, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
[4] Robin Med Inc, Baltimore, MD USA
[5] Brigham & Womens Hosp, Dept Neuroradiol, 75 Francis St, Boston, MA 02115 USA
来源
MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING | 2017年 / 10135卷
基金
美国国家卫生研究院;
关键词
MRI; Electromagnetic Tracking; Optical Tracking; Needle Intervention; navigation; data fusion;
D O I
10.1117/12.2253958
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
MRI-guided needle intervention for cryoablation is a promising way to relieve the pain and treat the cancer. However, the limited size of MRI bore makes it impossible for clinicians to perform the operation in the bore. The patients had to be moved into the bore for scanning to verify the position of the needle's tip and out for adjusting the needle's trajectory. Real-time needle tracking and shown in MR images is of importance for clinicians to perform the operation more efficiently. In this paper, we have instrumented the cryotherapy needle with a MRI-safe electromagnetic (EM) sensor and optical sensor to measure the needle's position and orientation. To overcome the limitation of line-of-sight for optical sensor and the poor dynamic performance of the EM sensor, Kalman filter based data fusion is developed. Further, we developed a navigation system in open-source software, 3D Slicer, to provide accurate visualization of the needle and the surrounding anatomy. Experiment of simulation the needle intervention at the entrance was performed with a realistic spine phantom to quantify the accuracy of the navigation using the retrospective analysis method. Eleven trials of needle insertion were performed independently. The target accuracy with the navigation using only EM sensor, only optical sensor and data fusion are 2.27 +/- 1.60 mm, 4.11 +/- 1.77 mm and 1.91 +/- 1.10 mm, respectively.
引用
收藏
页数:6
相关论文
共 50 条
[41]   Single shot MR tagging to quantify local tissue deformation during MRI-guided needle interventions: A feasibility study [J].
van den Bosch, Michiel R. ;
de Leeuw, Hendrik ;
Zwanenburg, Jaco J. M. ;
Lagendijk, Jan J. W. ;
Moerland, Marinus A. .
MEDICAL PHYSICS, 2011, 38 (10) :5321-5329
[42]   Intraoperative MRI-derived volumetric ablation margins and initial correlation with local outcome after MRI-guided cryoablation of renal tumors [J].
de Jager, Nienke S. ;
van Oostenbrugge, Tim J. ;
Paetz, Torben ;
Jenniskens, Sjoerd F. M. ;
Futterer, Jurgen J. ;
Langenhuijsen, Johan F. ;
Overduin, Christiaan G. .
CANCER IMAGING, 2023, 23 (01)
[43]   Intraoperative MRI-derived volumetric ablation margins and initial correlation with local outcome after MRI-guided cryoablation of renal tumors [J].
Nienke S. de Jager ;
Tim J. van Oostenbrugge ;
Torben Pätz ;
Sjoerd F. M. Jenniskens ;
Jurgen J. Fütterer ;
Johan F. Langenhuijsen ;
Christiaan G. Overduin .
Cancer Imaging, 23
[44]   Real-time color flow MRI [J].
Nayak, KS ;
Pauly, JM ;
Kerr, AB ;
Hu, BS ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (02) :251-258
[45]   Toward mechatronic MRI-guided focal laser ablation of the prostate: Robust registration for improved needle delivery [J].
Knull, Eric ;
Park, Claire Keun Sun ;
Bax, Jeffrey ;
Tessier, David ;
Fenster, Aaron .
MEDICAL PHYSICS, 2023, 50 (03) :1259-1273
[46]   MRI-guided core needle biopsy of the breast: Radiology-pathology correlation and impact on clinical management [J].
Lilly, Amy J. ;
Johnson, Meredith ;
Kuzmiak, Cherie M. ;
Ollila, David W. ;
O'Connor, Siobhan M. ;
Hertel, Johann D. ;
Calhoun, Benjamin C. .
ANNALS OF DIAGNOSTIC PATHOLOGY, 2020, 48
[47]   Imaging the breastfeeding swallow: Pilot study utilizing real-time MRI [J].
Mills, Nikki ;
Lydon, Anna-Maria ;
Davies-Payne, David ;
Keesing, Melissa ;
Geddes, Donna T. ;
Mirjalili, Seyed Ali .
LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2020, 5 (03) :572-579
[48]   MRI Reconstruction using Real-Time Motion Tracking: A Simulation Study [J].
Orchard, Jeff ;
Staruch, Robert .
2008 42ND ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS AND COMPUTERS, VOLS 1-4, 2008, :1910-+
[49]   lacZ as a Genetic Reporter for Real-Time MRI [J].
Bengtsson, Niclas E. ;
Brown, Gary ;
Scott, Edward W. ;
Walter, Glenn A. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) :745-753
[50]   Real-time, interactive MRI for cardiovascular interventions [J].
McVeigh, ER ;
Guttman, MA ;
Kellman, P ;
Raval, AN ;
Lederman, RJ .
ACADEMIC RADIOLOGY, 2005, 12 (09) :1121-1127