Evaluation of the radiopacity of different root canal sealers

被引:17
作者
Gorduysus, Melahat [1 ]
Avcu, Nihal [2 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Endodont, Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Oral Diag & Radiol, Ankara, Turkey
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2009年 / 108卷 / 03期
关键词
FILLING MATERIALS;
D O I
10.1016/j.tripleo.2009.04.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aims of this study were to compare the radiopacity of 8 root canal sealers relative to gutta-percha and dentin in standard discs and to evaluate the effect of these sealers on the radiopacity of root canal fillings in simulated canals. Study design: Radiographs were taken of 1-mm-thick specimens of 8 root canal sealers (Diaket, Endion, MTA, Endofil, Roeko Seal, Sealite, AH26, AH Plus) and gutta-percha, a 1-mm-thick human tooth slice, and aluminum stepwedge. Simulated canals were used to evaluate the effect of the sealer on radiopacity of the root fillings. After enlargement of the simulated canals with ProTaper instrument, root canals were filled with these 8 sealers alone and with single ProTaper gutta-percha cone. Radiographs of all filled simulated canals were taken with an aluminum stepwedge. Results: All the sealers demonstrated greater radiopacity than dentin (0.7940 mm Al) (P < .001). AH Plus showed the highest radiopacity in the standard disc group (Group 1) (8.9881 mm Al) (P < .001), and in the sealer group in simulated canals (Group 2) (9.2100 mm Al) (P < .001). In the sealer plus gutta-percha group in simulated canals (Group 3), Sealite plus gutta-percha showed greater radiopacity (8.4460 mm Al) (P < .001). Conclusion: Whether the opacity of the sealers alone is more or less than 3 mm Al, their radiopacity is increased when they are used in combination with gutta-percha, because of its higher radiopacity. However, when sealers are used in conjunction with gutta-percha, they can affect the radiopacity of the root canal filling according to their type and thickness. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e135-e140)
引用
收藏
页码:E135 / E140
页数:6
相关论文
共 21 条
[1]  
[Anonymous], 68762001 ISO
[2]   The effect of three different sealers on the radiopacity of root fillings in simulated canals [J].
Baksi , B. Guniz ;
Eyuboglu, Tan Firat ;
Sen, Bilge Hakan ;
Erdilek, Necdet .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (01) :138-141
[3]   RADIOPACITY OF ROOT-CANAL SEALERS [J].
BEYEROLSEN, EM ;
ORSTAVIK, D .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1981, 51 (03) :320-328
[4]   Radiopacity of a new root canal sealer, epiphany [J].
Bodrumlu, Emre ;
Sumer, A. Pinar ;
Gungor, Kahraman .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (05) :E59-E61
[5]  
Devito Karina Lopes, 2004, J. Appl. Oral Sci., V12, P290, DOI 10.1590/S1678-77572004000400007
[6]   RADIOPACITY OF IMPRESSION MATERIALS [J].
ELIASSON, ST ;
HAASKEN, B .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1979, 47 (05) :485-491
[7]  
ELMOWAFY OM, 1994, OPER DENT, V19, P11
[8]  
Funteas U R, 2003, Aust Endod J, V29, P43
[9]  
Gambarini Gianluca, 2006, Aust Endod J, V32, P31
[10]   THE USEFULNESS OF DYE-PENETRATION STUDIES REEXAMINED [J].
GOLDMAN, M ;
SIMMONDS, S ;
RUSH, R .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1989, 67 (03) :327-332