Optic nerve sonography and ophthalmic artery Doppler velocimetry in healthy pregnant women: an Australian cohort study

被引:10
作者
Kane, Stefan C. [1 ,2 ,3 ]
Dennis, Alicia T. [1 ,4 ,5 ,6 ]
Da Silva Costa, Fabricio [1 ,7 ,8 ]
Kornman, Louise H. [1 ,2 ,3 ]
Cade, Thomas J. [1 ,2 ]
Brennecke, Shaun P. [1 ,2 ]
机构
[1] Univ Melbourne, Royal Womens Hosp, Dept Obstet & Gynaecol, Parkville, Vic, Australia
[2] Royal Womens Hosp, Dept Maternal Fetal Med, Pregnancy Res Ctr, Parkville, Vic, Australia
[3] Royal Womens Hosp, Pauline Gandel Womens Imaging Ctr, Ultrasound Serv, Parkville, Vic, Australia
[4] Royal Womens Hosp, Dept Anaesthesia, Parkville, Vic, Australia
[5] Univ Melbourne, Dept Med & Radiol, Parkville, Vic, Australia
[6] Univ Melbourne, Dept Pharmacol & Therapeut, Parkville, Vic, Australia
[7] Monash Univ, Dept Obstet & Gynaecol, Clayton, Vic, Australia
[8] Univ Sao Paulo, Fac Med Ribeirao Preto, Hosp Clin, Dept Obstet & Ginecol, Ribeirao Preto, SP, Brazil
基金
英国医学研究理事会;
关键词
Doppler ultrasonography; hypertension; ophthalmic artery ultrasonography; optic nerve; preeclampsia; pregnancy; pregnancy induced hypertension; POSTPARTUM PREECLAMPTIC WOMEN; CENTRAL RETINAL ARTERIES; SHEATH DIAMETER; BLOOD-FLOW; NORMOTENSIVE PREGNANCIES; HYPERTENSIVE DISORDERS; INTRACRANIAL-PRESSURE; GESTATIONAL-AGE; ULTRASONOGRAPHY; ULTRASOUND;
D O I
10.1002/jcu.22735
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose Maternal ocular sonography offers a window into cerebrovascular and intracranial pressure changes in pregnancy. This study aimed to determine the Doppler velocimetric variables of the ophthalmic artery, and the mean diameter of the optic nerve sheath (ONSD), in an Australian cohort of healthy pregnant women. Methods A prospective observational cohort study of healthy women with uncomplicated singleton pregnancies in the third trimester was undertaken in a tertiary maternity service. A single prenatal ultrasonographic examination was performed on all participants, with a postnatal examination performed on a subgroup with uncomplicated deliveries. Results Fifty women were examined at a mean gestation of 35 weeks. The mean +/- SD Doppler variables in the ophthalmic artery were peak systolic velocity (PSV) 41.89 +/- 13.13 cm/s, second peak velocity 20.63 +/- 8.97 cm/s, end diastolic velocity 9.29 +/- 5.13 cm/s, pulsatility index 1.97 +/- 0.53, resistive index 0.78 +/- 0.07, peak ratio (second peak velocity/PSV) 0.49 +/- 0.12, while the mean ONSD was 4.34 +/- 0.4 mm. None of these variables had a demonstrable relationship with gestation or mean arterial pressure (MAP), nor did the sheath diameter have a relationship with any of the Doppler variables. Conclusions The ocular sonographic variables observed in this population are similar to those reported in other cohorts. No clear relationship could be identified in this cohort between ophthalmic artery Doppler variables and the ONSD, and between each of these variables and gestation or MAP.
引用
收藏
页码:531 / 539
页数:9
相关论文
共 59 条
  • [1] Prospective study of the hemodynamic behavior of ophthalmic arteries in postpartum preeclamptic women: A doppler evaluation
    Alves Borges, Jose Hilario
    Goes, Daniela A.
    de Araujo, Lucio Borges
    dos Santos, Maria Celia
    Debs Diniz, Angelica Lemos
    [J]. HYPERTENSION IN PREGNANCY, 2016, 35 (01) : 100 - 111
  • [2] [Anonymous], THESIS
  • [3] [Anonymous], 2021, INFLAMMATORY BOWEL D, DOI DOI 10.1201/9780429330766
  • [4] [Anonymous], NAT PER STAT UN AUST
  • [5] Anesthetic management of labor and delivery in patients with elevated intracranial pressure
    Anson, J. A.
    Vaida, S.
    Giampetro, D. M.
    McQuillan, P. M.
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2015, 24 (02) : 147 - 160
  • [6] Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia
    Ayaz, T
    Akansel, G
    Hayirlioglu, A
    Arslan, A
    Suer, N
    Kuru, I
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2003, 46 (03) : 244 - 249
  • [7] Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging
    Baeuerle, Jochen
    Schuchardt, Florian
    Schroeder, Laure
    Egger, Karl
    Weigel, Matthias
    Harloff, Andreas
    [J]. BMC NEUROLOGY, 2013, 13
  • [8] Transcranial and orbital Doppler ultrasound in normal pregnancy and preeclampsia
    Belfort, MA
    Giannina, G
    Herd, JA
    [J]. CLINICAL OBSTETRICS AND GYNECOLOGY, 1999, 42 (03) : 479 - 506
  • [9] Labetalol decreases cerebral perfusion pressure without negatively affecting cerebral blood flow in hypertensive gravidas.
    Belfort, MA
    Tooke-Miller, C
    Allen, JC
    Dizon-Townson, D
    Varner, MA
    [J]. HYPERTENSION IN PREGNANCY, 2002, 21 (03) : 185 - 197
  • [10] HORMONAL STATUS AFFECTS THE REACTIVITY OF THE CEREBRAL VASCULATURE
    BELFORT, MA
    SAADE, GR
    SNABES, M
    DUNN, R
    MOISE, KJ
    CRUZ, A
    YOUNG, R
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 172 (04) : 1273 - 1278