Strategies for the detection of target analytes using microfluidic paper-based analytical devices

被引:43
作者
Zheng, Wei [1 ]
Wang, Kan [1 ]
Xu, Hao [4 ]
Zheng, Chujun [1 ]
Cao, Bo [1 ]
Qin, Qi [1 ]
Jin, Qinghui [2 ,3 ]
Cui, Daxiang [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Engn Res Ctr Intelligent Diag & Treatmen, Sch Elect Informat & Elect Engn,Minist Educ, Dept Instrument Sci & Engn,Key Lab Thin Film & Mi, Shanghai 200240, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
[3] Ningbo Univ, Fac Elect Engn & Comp Sci, Ningbo 315211, Zhejiang, Peoples R China
[4] Shanghai Jiao Tong Univ, Sch Naval Architecture Ocean & Civil Engn, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Microfluidic paper-based analytical devices (μ PADs); Point-of-care testing (POCT); Immunological; HIGHLY SENSITIVE DETECTION; COLORIMETRIC DETERMINATION; MULTIPLEXED DETECTION; BIPOLAR ELECTRODE; URIC-ACID; MU-PAD; FLUORESCENCE; ASSAY; GLUCOSE; BIOSENSOR;
D O I
10.1007/s00216-021-03213-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microfluidic paper-based analytical devices (mu PADs) have developed rapidly in recent years, because of their advantages, such as small sample volume, rapid detection rates, low cost, and portability. Due to these characteristics, they can be used for in vitro diagnostics in the laboratory, or in the field, for a variety of applications, including food evaluation, disease screening, environmental monitoring, and drug testing. This review will present various detection methods employed by mu PADs and their respective applications for the detection of target analytes. These include colorimetry, electrochemistry, chemiluminescence (CL), electrochemiluminescence (ECL), and fluorescence-based methodologies. At the same time, the choice of labeling material and the design of microfluidic channels are also important for detection results. The construction of novel nanocomponents and different smart structures of paper-based devices have improved the performance of mu PADs and we will also highlight some of these in this manuscript. Additionally, some key challenges and future prospects for the use of mu PADs are briefly discussed.
引用
收藏
页码:2429 / 2445
页数:17
相关论文
共 104 条
[11]   Three-dimensional paper-based microfluidic electrochemical integrated devices (3D-PMED) for wearable electrochemical glucose detection [J].
Cao, Qingpeng ;
Liang, Bo ;
Tu, Tingting ;
Wei, Jinwei ;
Fang, Lu ;
Ye, Xuesong .
RSC ADVANCES, 2019, 9 (10) :5674-5681
[12]   Simple, distance-based measurement for paper analytical devices [J].
Cate, David M. ;
Dungchai, Wijitar ;
Cunningham, Josephine C. ;
Volckens, John ;
Henry, Charles S. .
LAB ON A CHIP, 2013, 13 (12) :2397-2404
[13]   High sensitivity and specificity simultaneous determination of lead, cadmium and copper using μPAD with dual electrochemical and colorimetric detection [J].
Chaiyo, Sudkate ;
Apiluk, Amara ;
Siangproh, Weena ;
Chailapakul, Orawon .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 233 :540-549
[14]   Fluorescence and visual detection of fluoride ions using a photoluminescent graphene oxide paper sensor [J].
Chen, Xiaochun ;
Yu, Shaoming ;
Yang, Liang ;
Wang, Jianping ;
Jiang, Changlong .
NANOSCALE, 2016, 8 (28) :13669-13677
[15]   Distance-based carcinoembryonic antigen assay on microfluidic paper immunodevice [J].
Chen, Ying ;
Chu, Weiru ;
Liu, Wei ;
Guo, Xiaoyan .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 :452-459
[16]   Paper-based chemiluminescence immunodevice for the carcinoembryonic antigen by employing multi-enzyme carbon nanosphere signal enhancement [J].
Chen, Ying ;
Chu, Weiru ;
Liu, Wei ;
Guo, Xiaoyan ;
Jin, Yan ;
Li, Baoxin .
MICROCHIMICA ACTA, 2018, 185 (03)
[17]   A simple and versatile paper-based electrochemiluminescence biosensing platform for hepatitis B virus surface antigen detection [J].
Chen, Yu ;
Wang, Jie ;
Liu, Zhongming ;
Wang, Xingang ;
Li, Xin ;
Shan, Guiqiu .
BIOCHEMICAL ENGINEERING JOURNAL, 2018, 129 :1-6
[18]   A new disposable microfluidic electrochemical paper-based device for the simultaneous determination of clinical biomarkers [J].
Cincotto, Fernando H. ;
Fava, Elson L. ;
Moraes, Fernando C. ;
Fatibello-Filho, Orlando ;
Faria, Ronaldo C. .
TALANTA, 2019, 195 :62-68
[19]   SEMIQUANTITATIVE SPECIFIC TEST PAPER FOR GLUCOSE IN URINE [J].
COMER, JP .
ANALYTICAL CHEMISTRY, 1956, 28 (11) :1748-1750
[20]   Portable and low-cost colorimetric office paper-based device for phenacetin detection in seized cocaine samples [J].
da Silva, Gabriela O. ;
de Araujo, William R. ;
Paixao, Thiago R. L. C. .
TALANTA, 2018, 176 :674-678