Transjugular versus percutaneous renal biopsy for the diagnosis of parenchymal disease: Comparison of sampling effectiveness and complications

被引:66
作者
Cluzel, P
Martinez, F
Bellin, MF
Michalik, Y
Beaufils, H
Jouanneau, C
Lucidarme, O
Deray, G
Grenier, PA
机构
[1] Univ Paris 06, Hop La Pitie Salpetriere, Diagnost & Intervent Polyvalent Radiol Serv, F-75651 Paris 13, France
[2] Univ Paris 06, Hop La Pitie Salpetriere, Serv Nephrol, F-75651 Paris, France
[3] INSERM, Unite 423, Paris, France
[4] INSERM, Unite 494, Paris, France
关键词
biopsies; complications; technology; kidney; biopsy;
D O I
10.1148/radiology.215.3.r00ma07689
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the effectiveness and safety of transjugular renal biopsy with those of percutaneous renal biopsy for diagnosis of renal parenchymal disease. MATERIALS AND METHODS: Results and complications of 400 consecutive transjugular renal biopsies performed between 1993 and 1998 with a modified Colapinto transjugular hepatic biopsy system were compared retrospectively with those of 400 percutaneous renal biopsies performed during the same period. Transjugular renal biopsy was associated with 14 Cardiac and 35 hepatic biopsies. Number of glomeruli per tissue core, adequacy of tissue core for histopathologic diagnosis, and rate and severity of complications were analyzed. RESULTS: Renal tissue was obtained with percutaneous renal biopsy in 382 (95.5%) of 400 patients and with transjugular renal biopsy in 383 (95.8%) of 400 patients. The mean numbers of intact glomeruli per tissue core with optical microscopy were 11.2 +/- 7.7 (SD) and 9.8 +/- 7.6 for percutaneous renal biopsy and transjugular renal biopsy, respectively. With immunofluorescent microscopy, the mean numbers were 6.4 +/- 5.3 and 4.6 +/- 4.6 for percutaneous renal biopsy and transjugular renal biopsy, respectively. Tissue cores were adequate for histopathologic diagnosis in 98.2% with both techniques. Major complications occurred with transjugular renal biopsy in four patients and with percutaneous renal biopsy in three patients. CONCLUSION: Use of transjugular renal biopsy provides diagnostic yield and safety similar to those of percutaneous renal biopsy and allows multiorgan biopsy during the same procedure. It can be recommended in patients with percutaneous renal biopsy contraindication or failure.
引用
收藏
页码:689 / 693
页数:5
相关论文
共 28 条
[1]  
ALWALL N, 1952, ACTA MED SCAND, V143, P430
[2]   RENAL BIOPSY WITH FORCEPS THROUGH THE FEMORAL VEIN [J].
BILBAO, JI ;
IDOATE, F ;
JOLY, MA ;
VAZQUEZ, C ;
SANGRO, B ;
LARREA, JA ;
LONGO, JM ;
PARDO, J .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 6 (04) :641-645
[3]   AN IMPROVED TECHNIQUE FOR ULTRASOUND GUIDED PERCUTANEOUS RENAL BIOPSY [J].
BIRNHOLZ, JC ;
KASINATH, BS ;
CORWIN, HL .
KIDNEY INTERNATIONAL, 1985, 27 (01) :80-82
[4]   NEEDLE-BIOPSY OF RENAL-ALLOGRAFTS - COMPARISON OF 2 TECHNIQUES [J].
BOGAN, ML ;
KOPECKY, KK ;
KRAFT, JL ;
HOLLADAY, AO ;
FILO, RS ;
LEAPMAN, SB ;
THOMALLA, JV .
RADIOLOGY, 1990, 174 (01) :273-275
[5]  
CHRISTENSEN J, 1995, ACTA RADIOL, V36, P276
[6]   CLINICAL UTILITY OF KIDNEY BIOPSIES IN THE DIAGNOSIS AND MANAGEMENT OF RENAL-DISEASE [J].
COHEN, AH ;
NAST, CC ;
ADLER, SG ;
KOPPLE, JD .
AMERICAN JOURNAL OF NEPHROLOGY, 1989, 9 (04) :309-315
[7]   CONVENTIONAL 15G NEEDLE TECHNIQUE FOR RENAL BIOPSY COMPARED WITH ULTRASOUND-GUIDED SPRING-LOADED 18G NEEDLE-BIOPSY [J].
COZENS, NJA ;
MURCHISON, JT ;
ALLAN, PL ;
WINNEY, RJ .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (775) :594-597
[8]  
CRONAN JJ, 1993, J INTERVENT RADIOL, V8, P49
[9]   EXPERIENCE WITH A NEW METHOD FOR PERCUTANEOUS RENAL BIOPSY [J].
DONOVAN, KL ;
THOMAS, DM ;
WHEELER, DC ;
MACDOUGALL, IC ;
WILLIAMS, JD .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1991, 6 (10) :731-733
[10]   PERCUTANEOUS NATIVE RENAL BIOPSY - COMPARISON OF A 1.2-MM SPRING-DRIVEN SYSTEM WITH A TRADITIONAL 2-MM HAND-DRIVEN SYSTEM [J].
DOYLE, AJ ;
GREGORY, MC ;
TERREROS, DA .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 23 (04) :498-503