Implementation and characterization of a 320-slice volumetric CT scanner for simulation in radiation oncology

被引:25
作者
Coolens, C. [1 ,2 ]
Breen, S. [1 ,2 ]
Purdie, T. G. [1 ,2 ]
Owrangi, A. [1 ]
Publicover, J. [1 ]
Bartolac, S. [1 ]
Jaffray, D. A. [1 ,2 ]
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
关键词
computed tomography; oncology; calibration; COMPUTED-TOMOGRAPHY; QUALITY-ASSURANCE; RECONSTRUCTION; CALIBRATION;
D O I
10.1118/1.3246352
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Effective target definition and broad employment of treatment response assessment with dynamic contrast-enhanced CT in radiation oncology requires increased speed and coverage for use within a single bolus injection. To this end, a novel volumetric CT scanner (Aquilion One, Toshiba, Tochigi Pref., Japan) has been installed at the Princess Margaret Hospital for implementation into routine CT simulation. This technology offers great advantages for anatomical and functional imaging in both scan speed and coverage. The aim of this work is to investigate the system's imaging performance and quality as well as CT quantification accuracy which is important for radiotherapy dose calculations. Methods: The 320-slice CT scanner uses a 160 mm wide-area (2D) solid-state detector design which provides the possibility to acquire a volumetric axial length of 160 mm without moving the CT couch. This is referred to as "volume" and can be scanned with a rotation speed of 0.35-3 s. The scanner can also be used as a 64-slice CT scanner and perform conventional (axial) and helical acquisitions with collimation ranges of 1-32 and 16-32 mm, respectively. Commissioning was performed according to AAPM Reports TG 66 and 39 for both helical and volumetric imaging. Defrise and other cone-beam image analysis tests were performed. Results: Overall, the imaging spatial resolution and geometric efficiency (GE) were found to be very good (>10 lp/mm, <1 mm spatial integrity and GE(160) (mm)=85%) and within the AAPM guidelines as well as IEC recommendations. Although there is evidence of some cone-beam artifacts when scanning the Defrise phantom, image quality was found to be good and sufficient for treatment planning (soft tissue noise <10 HU). Measurements of CT number stability and contrast-to-noise values across the volume indicate clinically acceptable scan accuracy even at the field edge. Conclusions: Initial experience with this exciting new technology confirms its accuracy for routine CT simulation within radiation oncology and allows for future investigations into specialized dynamic volumetric imaging applications. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3246352]
引用
收藏
页码:5120 / 5127
页数:8
相关论文
共 13 条
  • [1] *AAPM RAD THER COM, 1993, 39 AAPM RAD THER COM
  • [2] A local shift-variant Fourier model and experimental validation of circular cone-beam computed tomography artifacts
    Bartolac, Steven
    Clackdoyle, Rolf
    Noo, Frederic
    Siewerdsen, Jeff
    Moseley, Douglas
    Jaffray, David
    [J]. MEDICAL PHYSICS, 2009, 36 (02) : 500 - 512
  • [3] Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale
    Coolens, C
    Childs, PJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (11) : 1591 - 1603
  • [4] A CONE-BEAM RECONSTRUCTION ALGORITHM USING SHIFT-VARIANT FILTERING AND CONE-BEAM BACKPROJECTION
    DEFRISE, M
    CLACK, R
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) : 186 - 195
  • [5] Finch D., 1985, SIAM J APPL MATH, V43, P546
  • [6] *IEC, 2003, 60601244 IEC CT
  • [7] Tolerance levels for quality assurance of electron density values generated from CT in radiotherapy treatment planning
    Kilby, W
    Sage, J
    Rabett, V
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09) : 1485 - 1492
  • [8] Quality assurance for computed-tomography simulators and the computedtomography-simulation process: Report of the AAPM radiation therapy committee task group no. 66
    Mutic, S
    Palta, JR
    Butker, EK
    Das, IJ
    Huq, MS
    Loo, LND
    Salter, BJ
    McCollough, CH
    Van Dyk, J
    [J]. MEDICAL PHYSICS, 2003, 30 (10) : 2762 - 2792
  • [9] Investigation of lung nodule detectability in low-dose 320-slice computed tomography
    Silverman, J. D.
    Paul, N. S.
    Siewerdsen, J. H.
    [J]. MEDICAL PHYSICS, 2009, 36 (05) : 1700 - 1710
  • [10] IMAGE-RECONSTRUCTION FROM CONE-BEAM PROJECTIONS - NECESSARY AND SUFFICIENT CONDITIONS AND RECONSTRUCTION METHODS
    SMITH, BD
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1985, 4 (01) : 14 - 25