摘要
The glazing facade is embraced by architects, but this configuration may result in huge energy consumption. This research proposed a new double skin facade using photovoltaic (PV) blinds as a shading device (named PVB-DSF), which could realize multi-function of power generation, solar penetration reduction and flexible daylighting control. The purpose of this comparative study is to demonstrate the superb thermal performance of PVB-DSF. Experimental rig was built at hot-summer and cold-winter zone of China. The first stage comparative study was conducted to evaluate system thermal performance under the effects of ventilation modes, PV-blind angle and PV-blind spacing. The second stage study was conducted to compare thermal performance between PVB-DSF and standard DSF. A validated numerical model was used to describe standard DSF. The results suggested the operation of natural ventilation mode and indicated the evident influence of PV-blind spacing on system performance. The comparison study further demonstrated that PVB-DSF can save about 12.16% and 25.57% of energy in summer compared with conventional DSF with and without shading blinds. The insulation performance of PVB-DSF is shown by its daily average heat transfer coefficient which was as low as 2.247. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:281 / 293
页数:13
相关论文
共 50 条
  • [1] A comprehensive assessment methodology of the building integrated photovoltaic blind system
    Bahr, Wassim
    [J]. ENERGY AND BUILDINGS, 2014, 82 : 703 - 708
  • [2] Characteristic output of PV systems under partial shading or mismatch conditions
    Bai, Jianbo
    Cao, Yang
    Hao, Yuzhe
    Zhang, Zhen
    Liu, Sheng
    Cao, Fei
    [J]. SOLAR ENERGY, 2015, 112 : 41 - 54
  • [3] Investigation on energy performance of double skin facade in Hong Kong
    Chan, A. L. S.
    Chow, T. T.
    Fong, K. F.
    Lin, Z.
    [J]. ENERGY AND BUILDINGS, 2009, 41 (11) : 1135 - 1142
  • [4] Optimization of the performance of double-facades with integrated photovoltaic panels and motorized blinds
    Charron, Remi
    Athienitis, Andreas K.
    [J]. SOLAR ENERGY, 2006, 80 (05) : 482 - 491
  • [5] da Silva Marques F, 2015, BUILD ENVIRON, V87, P292
  • [6] Application of advanced glazing and overhangs in residential buildings
    Ebrahimpour, Abdulsalam
    Maerefat, Mehdi
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) : 212 - 219
  • [7] Nanoceramic VO2 thermochromic smart glass: A review on progress in solution processing
    Gao, Yanfeng
    Luo, Hongjie
    Zhang, Zongtao
    Kang, Litao
    Chen, Zhang
    Du, Jing
    Kanehira, Minoru
    Cao, Chuanxiang
    [J]. NANO ENERGY, 2012, 1 (02) : 221 - 246
  • [8] Exploring the advantages and challenges of double-skin facades (DSFs)
    Ghaffarianhoseini, Ali
    Ghaffarianhoseini, Amirhosein
    Berardi, Umberto
    Tookey, John
    Li, Danny Hin Wa
    Kariminia, Shahab
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 60 : 1052 - 1065
  • [9] Solar energy materials for glazing technologies
    Gorgolis, Georgios
    Karamanis, Dimitris
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2016, 144 : 559 - 578
  • [10] Building simulation as an assisting tool in decision making - Case study: With or without a double-skin facade?
    Hoseggen, R.
    Wachenfeldt, B. J.
    Hanssen, S. O.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (05) : 821 - 827