Development of Uric Acid Biosensor Using Gold Nanoparticles and Graphene Oxide Functionalized Micro-Ball Fiber Sensor Probe

被引:66
|
作者
Kumar, Santosh [1 ]
Singh, Ragini [2 ]
Zhu, Guo [1 ]
Yang, Qingshan [1 ]
Zhang, Xia [1 ]
Cheng, Shuang [2 ]
Zhang, Bingyuan [1 ]
Kaushik, Brajesh Kumar [3 ]
Liu, Feng-Zhen [4 ]
机构
[1] Liaocheng Univ, Shandong Key Lab Opt Commun Sci & Technol, Sch Phys Sci & Informat Technol, Liaocheng 252059, Shandong, Peoples R China
[2] Liaocheng Univ, Sch Agr Sci, Liaocheng 252059, Shandong, Peoples R China
[3] Indian Inst Technol Roorkee, Dept Elect & Commun Engn, Roorkee 247667, Uttar Pradesh, India
[4] Liaocheng Univ, Liaocheng Peoples Hosp, Med Coll, Liaocheng 252000, Shandong, Peoples R China
关键词
Uric acid; serum; micro-ball fiber structure; gold nanoparticles; graphene oxide; uricase; localized surface plasmon resonance;
D O I
10.1109/TNB.2019.2958891
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive and selective optical fiber-based enzymatic biosensor has been proposed in the present study for detection of uric acid (UA) in human serum. The working mechanism of sensor depends on surface plasma property and localized surface plasmon resonance technique. For this purpose, a micro-ball fiber sensor probe of $350 similar to\mu \text{m}$ diameter was fabricated using advanced fusion-splicer and coated with gold nanoparticles (AuNPs) and graphene oxide (GO) in order to enhance its sensitivity. UV-Visible spectrophotometer and high-resolution transmission electron microscope (HR-TEM) were used to characterize the AuNPs solution and GO aqueous dispersion. The absorbance spectrum of AuNPs and GO are recorded at 519 nm and 230 nm, respectively. The coating of AuNPs and GO over fiber surface were verified by using a scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy (EDX). Thereafter, sensor probe was functionalized with the specific enzyme i.e. uricase for the UA detection. The linearity response of uricase/GO/AuNPs-coated micro-ball optical fiber sensor is reported in the range of $10 similar to\mu \text{M}$ -1 mM UA concentrations. The reflectance of sensor linearly decreases with the increasing UA concentrations. Sensitivity of the sensor is 2.1 %/mM with a good slope of linearity with detection limit of $65.60 similar to\mu \text{M}$ . To test the accuracy of proposed sensor, UA concentration in serum samples have also tested by using proposed sensor and A5800 Automatic Biochemical Analyzer. The results of the developed sensor are consistent with the results of A5800 Automatic Biochemical Analyzer. Thus, proposed sensor can be successfully utilized for UA detection in human serum samples.
引用
收藏
页码:173 / 182
页数:10
相关论文
共 50 条
  • [1] LSPR based uric acid sensor using graphene oxide and gold nanoparticles functionalized tapered fiber
    Singh, Lokendra
    Singh, Ragini
    Zhang, Bingyuan
    Cheng, Shuang
    Kaushik, Brajesh Kumar
    Kumar, Santosh
    OPTICAL FIBER TECHNOLOGY, 2019, 53
  • [2] SMS Fiber Structure-Based Enzymatic Sensor Probe for Uric Acid Detection Using Gold Nanoparticles and Graphene Oxide
    Kumar Gupta, Vivek
    Choudhary, Kuldeep
    Kumar, Santosh
    IEEE SENSORS JOURNAL, 2024, 24 (09) : 14129 - 14136
  • [3] Gold Nanoparticles and Uricase Functionalized Tapered Fiber Sensor for Uric Acid Detection
    Singh, Lokendra
    Zhu, Guo
    Singh, Ragini
    Zhang, Bingyuan
    Wang, Wenjun
    Kaushik, Brajesh Kumar
    Kumar, Santosh
    IEEE SENSORS JOURNAL, 2020, 20 (01) : 219 - 226
  • [4] Development of Uric Acid Sensor Using Copper Oxide and Silver Nanoparticles Immobilized SMSMS Fiber Structure-Based Probe
    Agrawal, Niteshkumar
    Saha, Chinmoy
    Kumar, Chandrakanta
    Singh, Ragini
    Zhang, Bingyuan
    Kumar, Santosh
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (11) : 9097 - 9104
  • [5] Gold/zinc oxide nanoparticles functionalized tapered SMF-MMF-SMF-based sensor probe for uric acid detection
    Li, Muyang
    Singh, Ragini
    Zhang, Bingyuan
    Kumar, Santosh
    OPTICAL DESIGN AND TESTING XI, 2021, 11895
  • [6] Highly sensitive and selective sensor probe using glucose oxidase/gold nanoparticles/graphene oxide functionalized tapered optical fiber structure for detection of glucose
    Yang, Qingshan
    Zhu, Guo
    Singh, Lokendra
    Wang, Yu
    Singh, Ragini
    Zhang, Bingyuan
    Zhang, Xia
    Kumar, Santosh
    OPTIK, 2020, 208
  • [7] Flexible Electrochemical Sensor With Graphene and Gold Nanoparticles to Detect Dopamine and Uric Acid
    He, Wenzheng
    Ye, Xiongying
    Cui, Tianhong
    IEEE SENSORS JOURNAL, 2021, 21 (23) : 26556 - 26565
  • [8] Potential of a sensitive uric acid biosensor fabricated using hydroxyapatite nanowire/reduced graphene oxide/gold nanoparticle
    Chen, Yao
    Zhou, Wencui
    Ma, Jiahui
    Ruan, Feixia
    Qi, Xuezhen
    Cai, Yurong
    MICROSCOPY RESEARCH AND TECHNIQUE, 2020, 83 (03) : 268 - 275
  • [9] Ascorbic Acid Detection Using Gold Nanoparticles and Graphene Oxide-Coated SMS Optical Fiber-Based Sensor
    Gupta, Vivek Kumar
    Choudhary, Kuldeep
    Kumar, Santosh
    PLASMONICS, 2024,
  • [10] Development of Localized Surface Plasmon Resonance-Based Optical Fiber Biosensor for Immunoassay Using Gold Nanoparticles and Graphene Oxide Nanocomposite Film
    Chou, Hsueh-Tao
    Liao, Yong-Sen
    Wu, Tien-Ming
    Wang, Shih-Han
    Chiang, Kuan-Hua
    Su, Wei-Chao
    IEEE SENSORS JOURNAL, 2022, 22 (07) : 6593 - 6600