A clinical comparison study of three different methods for treatment of transverse patellar fractures

被引:14
|
作者
Meng, Depeng [1 ]
Xu, Peng [1 ]
Shen, Di [1 ]
Chen, Yu [1 ]
Zhu, Chengdong [1 ,2 ]
Hou, Chunlin [1 ]
Lin, Haodong [1 ]
Ouyang, Yueping [1 ]
机构
[1] Second Mil Med Univ, Changzheng Hosp, Dept Orthoped, Shanghai 200003, Peoples R China
[2] Peoples Hosp Yizheng City, Dept Orthoped, Yangzhou, Jiangsu, Peoples R China
关键词
CLASSIFICATION; COMPLICATIONS; FIXATION;
D O I
10.1016/j.jos.2018.08.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Tension bands structures are widely used to treat transverse patellar fractures. However, many implants-related complications have been reported. The purpose of this study is to evaluate effects and compare complications of three methods used to treat transverse patellar fractures, including titanium cable tension bands, compression screws with titanium cable cerclage, and X-shaped plating technique. Methods: From January 2010 to March 2016, 120 cases of transverse patellar fracture received open reduction and internal fixation with one of three methods: titanium cable tension band (group A), compression screws with titanium cable cerclage (group B), and X-shaped plating technique (group C). Of these, 108 cases were followed for >2 years. Clinical and radiographic data were retrospectively collected and statistically compared. Results: Final analysis included 108 patients (n = 38 in group A, 36 in B, and 34 in C). Reduction was satisfactory in all patients after surgery. No significant differences were noted in age, gender, time from injury to surgery, postoperative articular step-off, Lysholm score, and range of motion at 24 months among all groups. At final follow-up, 12 (31.6%) symptomatic implant complications were encountered in group A, along with 6 (16.7%) and 2 (5.9%) in groups B and C, respectively (p < 0.05). Conclusion: All three methods could achieve the goal of rigid fixation and early functional rehabilitation. However, the X-plate technique had the lowest risk of symptomatic implant complications and could thus be a safe and effective alternative for internal fixation of transverse patellar fractures. (C) 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 50 条
  • [41] Clinical comparison of two different plating methods in minimally invasive plate osteosynthesis for clavicular midshaft fractures: A randomized controlled trial
    Sohn, Hoon-Sang
    Shon, Min Soo
    Lee, Kyung-Hag
    Song, Si-Jung
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (11): : 2230 - 2238
  • [42] Clinical and financial comparison of operative and nonoperative treatment of displaced clavicle fractures
    Althausen, Peter L.
    Shannon, Steven
    Lu, Minggen
    O'Mara, Timothy J.
    Bray, Timothy J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (05) : 608 - 611
  • [43] Comparative study of three different fixation techniques for the treatment of Neer type IIb distal clavicle fractures: A retrospective cohort study
    Liu, Zhi-Qing
    Zhang, Ming-Shi
    Zhou, Zi-Fei
    Zhang, Lei
    Zheng, Long-Po
    FRONTIERS IN SURGERY, 2023, 10
  • [44] PROXIMAL HUMERUS FRACTURES: COMPARATIVE STUDY OF TWO DIFFERENT FIXATION METHODS
    Morelli, Ricardo Souza e Silva
    de Souza Travizanuto, Rodrigo Eisler
    ACTA ORTOPEDICA BRASILEIRA, 2010, 18 (02): : 79 - 84
  • [45] Comparison of clinical effects of two surgical approaches in the treatment of acetabular fractures
    Liu, Bing
    Shang, Hongtao
    Dong, Guixian
    Zhang, Ning
    Wang, Shengjie
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2023, 39 (04) : 1057 - 1061
  • [46] Comparison of compressive strength between three different plates for mandibular angle fractures fixation
    Lyrio, Mariana C. Negreiros
    Monnazzi, Marcelo Silva
    De Moraes, Marcio
    Hochuli-Vieira, Eduardo
    Nunes Reis, Jose Mauricio
    Pereira-Filho, Valfrido Antonio
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (05) : E277 - E280
  • [47] Biomechanical comparison of different screw-included angles in crossing screw fixation for transverse patellar fracture in level walking: a quasi-dynamic finite element study
    Chang, Chih-Wei
    Chen, Yen-Nien
    Chang, Hung-Chih
    Li, Chun-Ting
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [48] Comparison of the clinical efficacy of three cannulated screws with parallel distribution and inverted triangular distribution in the treatment of femoral neck fractures in the elderly
    Liu, Jiuxiang
    Zuo, Qiang
    Zhou, Hao
    Huang, Xiaowen
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2023, 26 (04)
  • [49] Five-pointed star lattice sutures for fixation of patella transverse fractures: a clinical study
    Tang, Xiaozheng
    Liu, Yayun
    Wu, Hongyan
    Gong, Feipeng
    Li, Yuxu
    Zeng, Hong
    Yu, Baofu
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (01) : 163 - 168
  • [50] Five-pointed star lattice sutures for fixation of patella transverse fractures: a clinical study
    Xiaozheng Tang
    Yayun Liu
    Hongyan Wu
    Feipeng Gong
    Yuxu Li
    Hong Zeng
    Baofu Yu
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 163 - 168