A clinical comparison study of three different methods for treatment of transverse patellar fractures

被引:14
|
作者
Meng, Depeng [1 ]
Xu, Peng [1 ]
Shen, Di [1 ]
Chen, Yu [1 ]
Zhu, Chengdong [1 ,2 ]
Hou, Chunlin [1 ]
Lin, Haodong [1 ]
Ouyang, Yueping [1 ]
机构
[1] Second Mil Med Univ, Changzheng Hosp, Dept Orthoped, Shanghai 200003, Peoples R China
[2] Peoples Hosp Yizheng City, Dept Orthoped, Yangzhou, Jiangsu, Peoples R China
关键词
CLASSIFICATION; COMPLICATIONS; FIXATION;
D O I
10.1016/j.jos.2018.08.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Tension bands structures are widely used to treat transverse patellar fractures. However, many implants-related complications have been reported. The purpose of this study is to evaluate effects and compare complications of three methods used to treat transverse patellar fractures, including titanium cable tension bands, compression screws with titanium cable cerclage, and X-shaped plating technique. Methods: From January 2010 to March 2016, 120 cases of transverse patellar fracture received open reduction and internal fixation with one of three methods: titanium cable tension band (group A), compression screws with titanium cable cerclage (group B), and X-shaped plating technique (group C). Of these, 108 cases were followed for >2 years. Clinical and radiographic data were retrospectively collected and statistically compared. Results: Final analysis included 108 patients (n = 38 in group A, 36 in B, and 34 in C). Reduction was satisfactory in all patients after surgery. No significant differences were noted in age, gender, time from injury to surgery, postoperative articular step-off, Lysholm score, and range of motion at 24 months among all groups. At final follow-up, 12 (31.6%) symptomatic implant complications were encountered in group A, along with 6 (16.7%) and 2 (5.9%) in groups B and C, respectively (p < 0.05). Conclusion: All three methods could achieve the goal of rigid fixation and early functional rehabilitation. However, the X-plate technique had the lowest risk of symptomatic implant complications and could thus be a safe and effective alternative for internal fixation of transverse patellar fractures. (C) 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 50 条
  • [31] Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
    Neto, Jorge Raduan
    de Moraes, Vinicius Ynoe
    Gomes dos Santos, Joao B.
    Faloppa, Flavio
    Belloti, Joao Carlos
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [32] Comparison of double-strand braided polyester sutures tension band (Nice knot) with cable tension band in transverse patellar fractures
    Yin, Zhaowei
    Yan, Junwei
    Ge, Dawei
    Yang, Lei
    Liang, Bin
    Fei, Junliang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (10): : 3085 - 3090
  • [33] Outcome of operative treatment of metastatic fractures of the humerus: a systematic review of twenty three clinical studies
    Janssen, Stein J.
    Teunis, Teun
    Hornicek, Francis J.
    Bramer, Jos A. M.
    Schwab, Joseph H.
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (04) : 735 - 746
  • [34] Comparison of four different treatment methods in distal clavicle fractures: Conservative treatment, locking plate, hook plate and tension band wiring
    Peker, Gokhan
    Abdioglu, Ahmet Atilla
    Karadeniz, Sercan
    Uygun, Huseyin
    Yukunc, Ismail
    Aslan, Oguzhan
    Karaca, Faruk
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2023, 14 : 401 - 405
  • [35] Comparison of Three Different Surgical Fixation Techniques in Pediatric Forearm Double Fractures
    Zeybek, Hakan
    Akti, Sefa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (08)
  • [36] Functional and radiological comparison of three cephalomedullary nails with different designs used in the treatment of unstable intertrochanteric femur fractures of elderly
    Yapici, Furkan
    Ucpunar, Hanifi
    Gur, Volkan
    Onac, Osman
    Alpay, Yakup
    Karakose, Resit
    Camurcu, Yalkin
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2022, 28 (05): : 668 - 677
  • [37] Titanium cannulated lag screw versus titanium cable-cannulated lag screw tension band for treatment of transverse patellar fractures
    Wang, Chengxue
    Yu, Jinlu
    Zhao, Yi
    Sun, Dahui
    Zhu, Dong
    Yu, Tiecheng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (07): : 13028 - 13034
  • [38] Clinical results of two different three-dimensional plate types for the treatment of mandibular angle fractures: a retrospective analysis
    Pfister, Jelena
    Shazwani, Farah Nur
    Mueller, Martin
    Burkhard, John-Patrik
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2024, 28 (04): : 1501 - 1507
  • [39] Three different patellar fixation techniques yield similar clinical and radiological outcomes in recurrent patellar dislocation undergoing medial patellofemoral ligament reconstruction
    Huo, Zhenhui
    Niu, Yingzhen
    Kang, Huijun
    Hao, Kuo
    Fan, Chongyi
    Li, Kehan
    Wang, Fei
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (11) : 2848 - 2858
  • [40] Comparison of three surgical fixation methods for dual-bone forearm fractures in older children: A retrospective cohort study
    Zheng, Wenhao
    Tao, Zhenyu
    Chen, Chunhui
    Zhang, Chuanxu
    Zhang, Hui
    Feng, Zhenhua
    Li, Hang
    Cheng, Liang
    Cai, Leyi
    Chen, Hua
    INTERNATIONAL JOURNAL OF SURGERY, 2018, 51 : 10 - 16