Recent developments in handheld and portable optosensing-A review

被引:125
作者
Fermin Capitan-Vallvey, Luis [1 ]
Palma, Alberto J. [2 ]
机构
[1] Univ Granada, Dept Analyt Chem, ECsens, Fac Sci, E-18071 Granada, Spain
[2] Univ Granada, Dept Elect & Comp Technol, ECsens, ETSIIT, E-18071 Granada, Spain
关键词
Handheld optosensing; Portable instrumentation; Review; Optoelectronic components; PLASMON RESONANCE IMMUNOSENSOR; NATURAL-WATER SAMPLES; NO-MOVING-PARTS; REAL-TIME; ATMOSPHERIC-PRESSURE; RAMAN-SPECTROSCOPY; CHEMICAL SENSORS; SENSITIVE DETECTION; STANDOFF DETECTION; WAVE-GUIDE;
D O I
10.1016/j.aca.2011.04.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recent developments in portable and handheld opto-chemical analytical instrumentation over the last decade (2000-2010) are reviewed. First, the characteristics of typical portable/handheld instrumentation are discussed from different points of view: in situ operation, low energy consumption, ease of use, and self-contained devices. These advancements have improved or hastened improvements in the development of miniaturized optoelectronic and optical components, mainly solid-state devices such as different types of semiconductor lasers, light-emitting diodes, and photodiodes. A brief review of advances in these components is also presented. The numerous examples of portable instrumentation presented have been classified according to direct-recognition and reagent-based sensing, and within these, by absorption and emission-based systems. The conclusion discusses some key trends and future perspectives for this technology. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 46
页数:20
相关论文
共 220 条
[1]  
ABDELRAHMAN EM, 2008, P SOC PHOTO-OPT INS, V7104
[2]   Design, Implementation, and Field Testing of a Portable Fluorescence- Based Vapor Sensor [J].
Aernecke, Matthew J. ;
Guo, Jian ;
Sonkusale, Sameer ;
Walt, David R. .
ANALYTICAL CHEMISTRY, 2009, 81 (13) :5281-5290
[3]   A surface plasmon resonance probe without optical fibers as a portable sensing device [J].
Akimoto, Takuo ;
Wada, Syunsuke ;
Karube, Isao .
ANALYTICA CHIMICA ACTA, 2008, 610 (01) :119-124
[4]   Field-deployable sniffer for 2,4-dinitrotoluene detection [J].
Albert, KJ ;
Myrick, ML ;
Brown, SB ;
James, DL ;
Milanovich, FP ;
Walt, DR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (15) :3193-3200
[5]   In situ detection of cocaine hydrochloride in clothing impregnated with the drug using benchtop and portable Raman spectroscopy [J].
Ali, Esam M. A. ;
Edwards, Howell G. M. ;
Hargreaves, Michael D. ;
Scowen, Ian J. .
JOURNAL OF RAMAN SPECTROSCOPY, 2010, 41 (09) :938-943
[6]  
ANAYA MD, 2009, P SOC PHOTO-OPT INS, V7499
[7]   Miniature Personal Ozone Monitor Based on UV Absorbance [J].
Andersen, Peter C. ;
Williford, Craig J. ;
Birks, John W. .
ANALYTICAL CHEMISTRY, 2010, 82 (19) :7924-7928
[8]   A portable fiber-optic pesticide biosensor based on immobilized cholinesterase and sol-gel entrapped bromcresol purple for in-field use [J].
Andreou, VG ;
Clonis, YD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (1-2) :61-69
[9]   Optically integrated microfluidic systems for cellular characterization and manipulation [J].
Applegate, Robert W., Jr. ;
Schafer, Dawn N. ;
Amir, Wafa ;
Squier, Jeff ;
Vestad, Tor ;
Oakey, John ;
Marr, David W. M. .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2007, 9 (08) :S122-S128
[10]  
Ashley Kevin, 2003, Appl Occup Environ Hyg, V18, P10, DOI 10.1080/10473220301384