DROP SIZE IN A LIQUID PULSED SIEVE-PLATE EXTRACTION COLUMN

被引:28
作者
Usman, M. R. [1 ]
Sattar, H. [1 ]
Hussain, S. N. [1 ]
Muhammad, H. [1 ]
Asghar, A. [1 ]
Afzal, W. [1 ]
机构
[1] Univ Punjab, Fac Engn & Technol, Inst Chem Engn & Technol, Lahore 54590, New Campus, Pakistan
关键词
Pulsation intensity; Superficial velocities; Mean drop diameter; Correlation; operating regimes; PREDICTION;
D O I
10.1590/S0104-66322009000400006
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The (Benzoic acid + kerosene + water) system was studied in a 5.0 cm diameter liquid pulsed liquid-liquid extraction column with a total number of 80 sieve plates. The effect of pulsation intensity, dispersed phase superficial velocity, and continuous phase superficial velocity on volume-surface mean diameter was studied. Generally, the mean drop diameter decreased more rapidly with the increase of pulsation intensities and superficial velocities at low pulsation intensities and superficial velocities. However, the effect was not found to be significant at higher pulsation intensities and higher superficial velocities. In the interpretation of the experimental results, the drop size was observed to be a function of the operating regimes (mixer-settler, dispersion, and emulsion) of the pulsed sieve-plate extraction column. The experimental mean drop diameters were compared to the most acceptable analytical drop size correlation developed by Kumar and Hartland (1986). The correlation proved to be in good agreement for the column operating in the dispersion regime.
引用
收藏
页码:677 / 683
页数:7
相关论文
共 15 条
[1]  
ASSENOV A, 1971, C R ACAD BULG SCI, V24, P1381
[2]   ON THE SIZE OF DROPS IN PULSED AND VIBRATING PLATE EXTRACTION COLUMNS [J].
BOYADZHIEV, L ;
SPASSOV, M .
CHEMICAL ENGINEERING SCIENCE, 1982, 37 (02) :337-340
[3]   Review article: The existing models for simulation of pulsed and reciprocating Columns - How well do they work in the real world? [J].
Grinbaum, B. .
SOLVENT EXTRACTION AND ION EXCHANGE, 2006, 24 (06) :795-822
[4]   PLATE WETTABILITY AND DROPLET DIAMETER IN A PULSED PERFORATED PLATE EXTRACTION COLUMN [J].
IKEDA, H ;
SUZUKI, A .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1992, 70 (02) :232-236
[5]  
KAGAN SZ, 1965, INT CHEM ENG, V5, P656
[6]  
Kubica J., 1977, INZ CHEM, V7, P903
[7]   Unified correlations for the prediction of drop size in liquid-liquid extraction columns [J].
Kumar, A ;
Hartland, S .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1996, 35 (08) :2682-2695
[8]   PREDICTION OF DROP SIZE IN PULSED PERFORATED-PLATE EXTRACTION COLUMNS [J].
KUMAR, A ;
HARTLAND, S .
CHEMICAL ENGINEERING COMMUNICATIONS, 1986, 44 (1-6) :163-182
[9]  
MISEK T, 1964, COLLECT CZECH CHEM C, V29, P1755
[10]   LONGITUDINAL DISPERSION IN PULSED PERFORATED-PLATE COLUMNS [J].
MIYAUCHI, T ;
OYA, H .
AICHE JOURNAL, 1965, 11 (03) :395-&