Morphobiochemical diagnosis of acute trabecular microfractures using gamma correction Tc-99m HDP pinhole bone scan with histopathological verification

被引:1
作者
Bahk, Yong-Whee [1 ,2 ]
Hwang, Seok-Ha
Lee, U-Young [3 ]
Chung, Yong-An [4 ]
Jung, Joo-Young [5 ]
Jeong, Hyeonseok S. [4 ]
机构
[1] Catholic Univ Korea, Sung Ae Gen Hosp, Dept Nucl Med, Seoul, South Korea
[2] Catholic Univ Korea, Sung Ae Gen Hosp, Dept Orthoped, Seoul, South Korea
[3] Catholic Univ Korea, Catholic Inst Appl Anat, Dept Anat, Seoul, South Korea
[4] Catholic Univ Korea, Incheon St Marys Hosp, Dept Radiol, Seoul, South Korea
[5] Catholic Univ Korea, Coll Med, Biomed Engn & Res Inst, Seoul, South Korea
关键词
gamma correction pinhole bone scan; morphobiochemical diagnosis; trabecular microfracture; KNEE;
D O I
10.1097/MD.0000000000008419
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We prospectively performed gamma correction pinhole bone scan (GCPBS) and histopathologic verification study to make simultaneous morphobiochemical diagnosis of trabecular microfractures (TMF) occurred in the femoral head as a part of femoral neck fracture.Materials consisted of surgical specimens of the femoral head in 6 consecutive patients. The specimens were imaged using Tc-99m hydroxymethylene diphosphonate (HDP) pinhole scan and processed by the gamma correction. After cleansing with 10% formalin solution, injured specimen surface was observed using a surgical microscope to record TMF. Morphological findings shown in the photograph, naive pinhole bone scan, GCPBS, and hematoxylin-eosin (H&E) stain of the specimen were reciprocally correlated for histological verification and the usefulness of suppression and enhancement of Tc-99m HDP uptake was biochemically investigated in TMF and edema and hemorrhage using gamma correction.On the one hand, GCPBS was able to depict the calcifying calluses in TMF with enhanced Tc-99m HDP uptake. They were pinpointed, speckled, round, ovoid, rod-like, geographic, and crushed in shape. The smallest callus measured was 0.23mm in this series. On the other hand, GCPBS biochemically was able to discern the calluses with enhanced high Tc-99m HDP uptake from the normal and edema dipped and hemorrhage irritated trabeculae with washed out uptake.Morphobiochemically, GCPBS can clearly depict microfractures in the femoral head produced by femoral neck fracture. It discerns the microcalluses with enhanced Tc-99m HDP uptake from the intact and edema dipped and hemorrhage irritated trabeculae with suppressed washed out Tc-99m HDP uptake. Both conventional pinhole bone scan and gamma correction are useful imaging means to specifically diagnose the microcalluses naturally formed in TMF.
引用
收藏
页数:6
相关论文
共 24 条
[1]   Gamma correction 99mTc-hydroxymethylene diphosphonate pinhole bone scan diagnosis and histopathological verification of trabecular contusion in young rats [J].
Bahk, Yong-Whee ;
Chung, Yong-An ;
Lee, U-Young ;
Park, Sang In .
NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (09) :988-991
[2]   Novel use of gamma correction for precise 99mTc-HDP pinhole bone scan diagnosis and classification of knee occult fractures [J].
Bahk, Yong-Whee ;
Jeon, Ho-Seung ;
Kim, Jang Min ;
Park, Jung Mee ;
Chung, Yong-An ;
Kim, E. Edmund ;
Kim, Sung-Hoon ;
Chung, Soo-Kyo .
SKELETAL RADIOLOGY, 2010, 39 (08) :807-813
[3]  
Bahk YW, 2013, GAMMA CORRECTION PIN, P209
[4]   TRABECULAR MICROFRACTURE [J].
FAZZALARI, NL ;
PARFITT ;
BURR ;
SNYDER ;
FYHRIE ;
MARTIN .
CALCIFIED TISSUE INTERNATIONAL, 1993, 53 :S143-S147
[5]  
FRANCIS MD, 1980, J NUCL MED, V21, P1185
[6]  
Frost H M, 1973, Clin Endocrinol Metab, V2, P257, DOI 10.1016/S0300-595X(73)80043-X
[7]  
Ito Masako, 2011, Nihon Rinsho, V69, P1233
[8]   Pixelized Measurement of Tc-99m-HDP Micro Particles Formed in Gamma Correction Phantom Pinhole Scan: a Reference Study [J].
Jung, Joo-Young ;
Cheon, Gi Jeong ;
Lee, Yun-Sang ;
Ha, Seunggyun ;
Chae, Mi-Hye ;
Chung, Yong-An ;
Yoon, Do Kyun ;
Bahk, Yong-Whee .
NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 50 (03) :207-212
[9]   Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data [J].
Klintstrom, Eva ;
Smedby, Orjan ;
Moreno, Rodrigo ;
Brismar, Torkel B. .
SKELETAL RADIOLOGY, 2014, 43 (02) :197-204
[10]   Traumatic bone bruising - A review article [J].
Mandalia, V. ;
Henson, J. H. L. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 67 (01) :54-61