An ion balance for ultra-high-precision atomic mass measurements

被引:108
作者
Rainville, S
Thompson, JK
Pritchard, DE
机构
[1] MIT, MIT Harvard Ctr Ultracold Atoms, Elect Res Lab, Cambridge, MA 02139 USA
[2] MIT, Dept Phys, Cambridge, MA 02139 USA
关键词
D O I
10.1126/science.1092320
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We have developed the analog of a double-pan balance for determining the masses of single molecular ions from the ratio of their two cyclotron frequencies. By con. ning two different ions on the same magnetron orbit in a Penning trap, we balance out many sources of noise and error ( such as fluctuations of the magnetic field). To minimize the systematic error associated with the Coulomb interaction between the two ions, they are kept about 1 millimeter apart from each other, resulting in fractional uncertainty below 1 x 10(-11). Such precision opens the door to numerous applications of mass spectrometry, including metrology, fundamental physics, and weighing chemical bonds.
引用
收藏
页码:334 / 338
页数:5
相关论文
共 26 条
[1]  
BELER T, 2002, PHYS REV LETT, V88
[2]   SMILETRAP -: A Penning trap facility for precision mass measurements using highly charged ions [J].
Bergström, I ;
Carlberg, C ;
Fritioff, T ;
Douysset, G ;
Schönfelder, J ;
Schuch, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (03) :618-651
[3]   Penning trap measurements of the masses cog 133Cs, 87,85Rb, and 23Na with uncertainties ≤0.2 ppb [J].
Bradley, MP ;
Porto, JV ;
Rainville, S ;
Thompson, JK ;
Pritchard, DE .
PHYSICAL REVIEW LETTERS, 1999, 83 (22) :4510-4513
[4]   GEONIUM THEORY - PHYSICS OF A SINGLE ELECTRON OR ION IN A PENNING TRAP [J].
BROWN, LS ;
GABRIELSE, G .
REVIEWS OF MODERN PHYSICS, 1986, 58 (01) :233-311
[5]  
Chase M., 1998, NIST JANAF THEMOCHEM, V4th edn
[6]   MODE-COUPLING IN A PENNING TRAP - PI-PULSES AND A CLASSICAL AVOIDED CROSSING [J].
CORNELL, EA ;
WEISSKOFF, RM ;
BOYCE, KR ;
PRITCHARD, DE .
PHYSICAL REVIEW A, 1990, 41 (01) :312-315
[7]   2 IONS IN A PENNING TRAP - IMPLICATIONS FOR PRECISION MASS-SPECTROSCOPY [J].
CORNELL, EA ;
BOYCE, KR ;
FYGENSON, DLK ;
PRITCHARD, DE .
PHYSICAL REVIEW A, 1992, 45 (05) :3049-3059
[8]   ACCURATE ATOMIC MASSES FOR FUNDAMENTAL METROLOGY [J].
DIFILIPPO, F ;
NATARAJAN, V ;
BOYCE, KR ;
PRITCHARD, DE .
PHYSICAL REVIEW LETTERS, 1994, 73 (11) :1481-1484
[9]   Precise atomic mass values near 132Sn:: The resolution of a puzzle [J].
Fogelberg, B ;
Mezilev, KA ;
Mach, H ;
Isakov, VI ;
Slivova, J .
PHYSICAL REVIEW LETTERS, 1999, 82 (09) :1823-1826
[10]   Precision mass spectroscopy of the antiproton and proton using simultaneously trapped particles [J].
Gabrielse, G ;
Khabbaz, A ;
Hall, DS ;
Heimann, C ;
Kalinowsky, H ;
Jhe, W .
PHYSICAL REVIEW LETTERS, 1999, 82 (16) :3198-3201