Influence of instrument size on the accuracy of different apex locators:: An in vitro study

被引:45
作者
Briseno-Marroquin, Benjamin [1 ]
Frajlich, Santiago [2 ]
Goldberg, Fernando [2 ]
Willershausen, Brita [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Operat Dent, D-55131 Mainz, Germany
[2] Univ USAL AOA, Buenos Aires, DF, Argentina
关键词
apex locators; instrument size; working length;
D O I
10.1016/j.joen.2008.02.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this in vitro investigation was to determine the accuracy of 4 different electronic apex locators (EALs) with 3 different instrument sizes. For this study 146 roots were embedded in an agar solution. Electronic measurements were made to the physiologic foramen (apical constriction) with the Elements Apex Locator, Justy II, Raypex 5, and ProPex II and K-type files sizes 08, 10, and 15. Statistical significances were calculated with the sign test (P < .001). Exact measurements to the physiologic foramen were made with the Elements Apex Locator, 36.99%, 39.04%, and 44.93%; Justy II, 38.62%, 32.41%, and 43.41%; Raypex 5, 42.76%, 39.31%, and 39.06%; and ProPex II, 38.62%, 43.45%, and 40.63% of the time with instrument sizes 08, 10, and 15, respectively. No significant differences were found between the actual working length and EALs/instrument size. A nonsignificant higher number of unstable measurements were observed in all EALs with instrument size 15.
引用
收藏
页码:698 / 702
页数:5
相关论文
共 28 条
[1]   Ex vivo evaluation of the capacity of the Tri Auto ZX to locate the apical foramen during root canal retreatment [J].
Alves, AMH ;
Felippe, MCS ;
Felippe, WT ;
Rocha, MJC .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (10) :718-724
[2]   Influence of embedding media on the assessment of electronic apex locators [J].
Baldi, Jarcio V. ;
Victorino, Fausto R. ;
Bernardes, Ricardo A. ;
de Moraes, Ivaldo G. ;
Bramante, Colvis M. ;
Garcia, Roberto B. ;
Bernardineli, Norberti .
JOURNAL OF ENDODONTICS, 2007, 33 (04) :476-479
[3]   The ability of two apex locators to locate the apical foramen: An in vitro study [J].
Cunha D'Assuncao, Fabio Luiz ;
de Albuquerque, Diana Santana ;
de Queiroz Ferreira, Linalda Correia .
JOURNAL OF ENDODONTICS, 2006, 32 (06) :560-562
[4]   An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals [J].
Dunlap, CA ;
Remeikis, NA ;
BeGole, EA ;
Rauschenberger, CR .
JOURNAL OF ENDODONTICS, 1998, 24 (01) :48-50
[5]   Determining the apical terminus of root-end resected teeth using three modern apex locators:: a comparative ex vivo study [J].
ElAyouti, A ;
Kimionis, I ;
Chu, AL ;
Löst, C .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (11) :827-833
[6]   The influence of irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece [J].
Erdemir, A. ;
Eldeniz, A. U. ;
Ari, H. ;
Belli, S. ;
Esener, T. .
INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (05) :391-397
[7]   Evaluation of the accuracy of three electronic apex locators using glass tubules [J].
Fan, W ;
Fan, B ;
Gutmann, JL ;
Bian, Z ;
Fan, MW .
INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (02) :127-135
[8]   In vitro evaluation of the ability of three apex locators to determine the working length during retreatment [J].
Goldberg, F ;
Marroquín, BB ;
Frajlich, S ;
Dreyer, C .
JOURNAL OF ENDODONTICS, 2005, 31 (09) :676-678
[9]   In vivo determination of root canal length:: a preliminary report using the Tri Auto ZX apex-locating handpiece [J].
Grimberg, F ;
Banegas, G ;
Chiacchio, L ;
Zmener, O .
INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (07) :590-593
[10]  
Grove CJ, 1930, J Am Dent Assoc., V17, P293, DOI [10.14219/jada.archive.1930.0049, DOI 10.14219/JADA.ARCHIVE.1930.0049]