Detection of Legionella pneumophila serogroup 1 antigen in respiratory samples using an immunochromatographic membrane test

被引:0
|
作者
Higa, Futoshi [1 ]
Koide, Michio [1 ]
Furugen, Makoto [1 ]
Akamine, Morikazu [1 ]
Hibiya, Kenji [1 ]
Haranaga, Shusaku [1 ]
Yara, Satomi [1 ]
Tateyama, Masao [1 ]
Yamane, Nobuhisa [2 ]
Fujita, Jiro [1 ]
机构
[1] Univ Ryukyus, Grad Sch Med, Dept Med & Therapeut, Okinawa 9030215, Japan
[2] Univ Ryukyus, Grad Sch Med, Dept Clin Labs, Okinawa 9030215, Japan
关键词
bronchial washing; diagnosis of commnunity-acquired pneumonia; Legionella pneumonia; immunochromatographic test;
D O I
10.1016/j.mimet.2008.03.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The immunochromatographic membrane test (ICT) efficacy of Legionella antigen detection (Binax Now Legionella (R)) was evaluated using respiratory samples, including bronchial washings (44 cases) and sputum (128 cases), from suspected Legionella pneumonia patients. The ICT results using respiratory samples agreed well with isolation of L. pneumophila SG1 and ICT using urines. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 122
页数:2
相关论文
共 50 条
  • [21] Comparison of radioimmunoassay and enzyme immunoassay kits for detection of Legionella pneumophila serogroup 1 antigen in both concentrated and nonconcentrated urine samples
    Dominguez, JA
    Matas, L
    Manterola, JM
    Blavia, R
    Sopena, N
    Belda, FJ
    Padilla, E
    Gimenez, M
    Sabria, M
    Morera, J
    Ausina, V
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (06) : 1627 - 1629
  • [22] Detection of Legionella pneumophila serogroup 1 antigen in nonconcentrated urine and urine concentrated by selective ultrafiltration
    Dominguez, JA
    Manterola, JM
    Blavia, R
    Sopena, N
    Belda, FJ
    Padilla, E
    Gimenez, M
    Sabria, M
    Morera, J
    Ausina, V
    JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (09) : 2334 - 2336
  • [23] Comparison of diagnostic sensitivities of three assays (Bartels enzyme immunoassay [EIA], Biotest EIA, and Binax NOW immunochromatographic test) for detection of Legionella pneumophila serogroup 1 antigen in urine
    Guerrero, C
    Toldos, CM
    Yagüe, G
    Ramírez, C
    Rodríguez, T
    Segovia, M
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) : 467 - 468
  • [24] Comparison of Binax Legionella Urinary Antigen EIA kit with Binax RIA Urinary Antigen kit for detection of Legionella pneumophila serogroup 1 antigen
    Hackman, BA
    Plouffe, JF
    Benson, RF
    Fields, BS
    Breiman, RF
    JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (06) : 1579 - 1580
  • [25] Rapid diagnosis of Legionella pneumophila serogroup 1 infection with the Binax enzyme immunoassay urinary antigen test
    Kazandjian, D
    Chiew, R
    Gilbert, GL
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (04) : 954 - 956
  • [26] Evaluation of the SD Bioline test, a new assay for detecting Legionella pneumophila serogroup 1 antigen in urine
    Bruin, J. P.
    Diederen, B. M. W.
    JOURNAL OF INFECTION, 2012, 64 (01) : 113 - 114
  • [27] DETECTION OF LEGIONELLA-PNEUMOPHILA SEROGROUP-1 URINARY ANTIGEN USING AN ENHANCED CHEMI-LUMINESCENCE ELISA
    SAMUEL, D
    HARRISON, TG
    TAYLOR, AG
    JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1988, 2 (04): : 251 - 251
  • [28] Detection of Legionella pneumophila antigen in urine samples by the BinaxNOW immunochromatographic assay and comparison with both Binax Legionella Urinary Enzyme Immunoassay (EIA) and Biotest Legionella urinary antigen EIA
    Helbig, JH
    Uldum, SA
    Lück, PC
    Harrison, TG
    JOURNAL OF MEDICAL MICROBIOLOGY, 2001, 50 (06) : 509 - 516
  • [29] ISOLATION OF A SEROGROUP 1-SPECIFIC ANTIGEN FROM LEGIONELLA-PNEUMOPHILA
    FLESHER, AR
    JENNINGS, HJ
    LUGOWSKI, C
    KASPER, DL
    JOURNAL OF INFECTIOUS DISEASES, 1982, 145 (02): : 224 - 233
  • [30] A CASE OF EMPYEMA DUE TO LEGIONELLA PNEUMOPHILA SEROGROUP 1 WITH NEGATIVE URINARY ANTIGEN
    Li, T.
    CHEST, 2020, 157 (06) : 99A - 99A