Development and evaluation of a Luminex multiplex serology assay to detect antibodies to bovine herpes virus 1, parainfluenza 3 virus, bovine viral diarrhoea virus, and bovine respiratory syncytial virus, with comparison to existing ELISA detection methods

被引:36
作者
Anderson, Steve [1 ]
Wakeley, Phil [1 ]
Wibberley, Guy [1 ]
Webster, Kath [1 ]
Sawyer, Jason [1 ]
机构
[1] Vet Labs Agcy, Addlestone KT15 3NB, Surrey, England
关键词
Luminex; ELISA; Crude antigens; Serology; LINKED-IMMUNOSORBENT-ASSAY; NEUTRALIZATION TESTS; COMPLEMENT-FIXATION; IMMUNOASSAY; GLYCOPROTEIN; PLATFORMS; EPITOPES; CATTLE;
D O I
10.1016/j.jim.2011.01.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Detection of circulating antibodies to bovine herpes virus 1 (BHV-1), parainfluenza 3 virus (PI3V), bovine viral diarrhoea virus (BVDV) and bovine respiratory syncytial virus (BRSV) using ELISA is widely used for veterinary diagnostics and surveillance. In this paper, the potential of a multiplex serology test based on Luminex technology, where all antibodies are simultaneously detected in a single assay was investigated. The performance of "in-house" separate ELISAs which use relatively crude lysates of cultured virus as capture antigens, was compared to the multiplex assay where the same antigens were covalently bound to the fluorescent beads used in the Luminex platform. A panel of field serum samples was tested by the multiplex assay in parallel with the separate routine ELISAs to provide a comparison between tests. The BHV-1 and PI3V components of the multiplex test showed similar sensitivities and specificities to the separate "in-house" ELISAs. The performance of the BVDV and BRSV components was less successful and was attributed to relatively low signal strength for these antigens, leading to higher assay variability and a reduced ability to distinguish positive and negative samples compared to the "in-house" ELISAs. The results illustrated that antigens commonly used successfully in ELISAs cannot always be transferred for use in alternative assay systems. The use of recombinant BVDV E2 protein was investigated and was shown to lead to an appreciable increase in signal strength compared to the use of crude BVDV antigen in the Luminex system. Crown Copyright (C) 2011 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:79 / 88
页数:10
相关论文
共 22 条
[1]   Simultaneous detection of antibodies to foot-and-mouth disease non-structural proteins 3ABC, 3D, 3A and 3B by a multiplexed Luminex assay to differentiate infected from vaccinated cattle [J].
Clavijo, A ;
Hole, K ;
Li, MY ;
Collignon, B .
VACCINE, 2006, 24 (10) :1693-1704
[2]   Optimization and validation of a multiplexed Luminex assay to quantify antibodies to neutralizing epitopes on human papillomaviruses 6, 11, 16, and 18 [J].
Dias, D ;
Van Doren, J ;
Schlottmann, S ;
Kelly, S ;
Puchalski, D ;
Ruiz, W ;
Boerckel, P ;
Kessler, J ;
Antonello, JM ;
Green, T ;
Brown, M ;
Smith, J ;
Chirmule, N ;
Barr, E ;
Jansen, KU ;
Esser, MT .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2005, 12 (08) :959-969
[3]   NEUTRALIZING MONOCLONAL-ANTIBODIES TO BOVINE VIRAL DIARRHEA VIRUS BIND TO THE 56K TO 58K GLYCOPROTEIN [J].
DONIS, RO ;
CORAPI, W ;
DUBOVI, EJ .
JOURNAL OF GENERAL VIROLOGY, 1988, 69 :77-86
[4]   Multiplex bead array assays: Performance evaluation and comparison of sensitivity to ELISA [J].
Elshal, MF ;
McCoy, JP .
METHODS, 2006, 38 (04) :317-323
[5]   Recombinant Helicobacter bilis protein P167 for mouse serodiagnosis in a multiplex microbead assay [J].
Feng, SL ;
Kendall, LV ;
Hodzic, E ;
Wong, S ;
Lorenzana, E ;
Freet, K ;
Ku, KS ;
Luciw, PA ;
Barthold, SW ;
Khan, IH .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2004, 11 (06) :1094-1099
[6]   Comparison of Multiplex Immunoassay Platforms [J].
Fu, Qin ;
Zhu, Jie ;
Van Eyk, Jennifer E. .
CLINICAL CHEMISTRY, 2010, 56 (02) :314-318
[7]  
GILLETTE KG, 1983, AM J VET RES, V44, P2251
[8]   A MODIFIED ROC ANALYSIS FOR THE SELECTION OF CUTOFF VALUES AND THE DEFINITION OF INTERMEDIATE RESULTS OF SERODIAGNOSTIC TESTS [J].
GREINER, M ;
SOHR, D ;
GOBEL, P .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 185 (01) :123-132
[9]   Comparative evaluation of indirect and sandwich ELISA for the detection of antibodies to bovine respiratory syncytial virus (BRSV) in dairy cattle [J].
Hazari, S ;
Panda, HK ;
Kar, BC ;
Das, BR .
COMPARATIVE IMMUNOLOGY MICROBIOLOGY AND INFECTIOUS DISEASES, 2002, 25 (01) :59-68
[10]  
HEBERT CN, 1985, J BIOL STAND, P243