Quartz Tuning Fork as in-situ sensor of bacterial biofilm

被引:6
作者
Piasecki, Tomasz [1 ]
Gula, Grzegorz [2 ]
Waszczuk, Karol [1 ]
Drulis-Kawa, Zuzanna [2 ]
Gotszalk, Teodor [1 ]
机构
[1] Wroclaw Univ Technol, Fac Microsyst Elect & Photon, Z Janiszewskiego 11-17, PL-50372 Wroclaw, Poland
[2] Univ Wroclaw, Inst Genet & Microbiol, PL-51148 Wroclaw, Poland
来源
28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014) | 2014年 / 87卷
关键词
Pseudomonas aeruginosa; biofilm; quartz tuning fork; ringdown; resonant frequency; viscosity; density;
D O I
10.1016/j.proeng.2014.11.740
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Piezoelectric Quartz Tuning Forks (QTFs) were used as a biofilm formation sensors. Modulated excitation technique allowed to measure the current generated by the QTF during the ringdown of the oscillations at conductive environments such as a liquid culture growth medium. New algorithm of the digital analysis of the ring-down signal was elaborated and used to determine the decay time constant of the vibrations and the damped vibration frequency. The dependence of these parameters on the time for QTF placed in liquid growth medium contained four strains of Pseudomonas aeruginosa was measured. It allowed to detect the biofilm formation at the QTF after few hours of incubation for all used strains (2 hours for PA01 strain). (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:369 / 372
页数:4
相关论文
共 11 条
[1]  
Ali Z., 2003, J THERMAL ANAL CALOR, V71, P355
[2]  
[Anonymous], 2001, IEEE Standard for Terminology and Test Methods for Analog-to-Digital Converters
[3]   Application of quartz tuning forks for detection of endotoxins and Gram-negative bacterial cells by monitoring of Limulus Amebocyte Lysate coagulation [J].
Chalupniak, Andrzej ;
Waszczuk, Karol ;
Halubek-Gluchowska, Katarzyna ;
Piasecki, Tomasz ;
Gotszalk, Teodor ;
Rybka, Jacek .
BIOSENSORS & BIOELECTRONICS, 2014, 58 :132-137
[4]   The biofilm matrix [J].
Flemming, Hans-Curt ;
Wingender, Jost .
NATURE REVIEWS MICROBIOLOGY, 2010, 8 (09) :623-633
[5]   Mechanisms of biofilm resistance to antimicrobial agents [J].
Mah, TFC ;
O'Toole, GA .
TRENDS IN MICROBIOLOGY, 2001, 9 (01) :34-39
[6]   Pseudomonas aeruginosa Attachment on QCM-D Sensors: The Role of Cell and Surface Hydrophobicities [J].
Marcus, Ian M. ;
Herzberg, Moshe ;
Walker, Sharon L. ;
Freger, Viatcheslav .
LANGMUIR, 2012, 28 (15) :6396-6402
[7]   Evaluation of Pseudomonas aeruginosa biofilm formation using Quartz Tuning Forks as impedance sensors [J].
Piasecki, Tomasz ;
Gula, Grzegorz ;
Nitsch, Karol ;
Waszczuk, Karol ;
Drulis-Kawa, Zuzanna ;
Gotszalk, Teodor .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 189 :60-65
[8]   Real-time monitoring of the development and stability of biofilms of Streptococcus mutans using the quartz crystal microbalance with dissipation monitoring [J].
Schofield, Amy L. ;
Rudd, Timothy R. ;
Martin, David. S. ;
Fernig, David G. ;
Edwards, Clive .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (03) :407-413
[9]   Application of piezoelectric tuning forks in liquid viscosity and density measurements [J].
Waszczuk, K. ;
Piasecki, T. ;
Nitsch, K. ;
Gotszalk, T. .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) :517-523
[10]   Evaluation of Pseudomonas aeruginosa biofilm formation using piezoelectric tuning fork mass sensors [J].
Waszczuk, K. ;
Gula, G. ;
Swiatkowski, M. ;
Olszewski, J. ;
Herwich, W. ;
Drulis-Kawa, Z. ;
Gutowicz, J. ;
Gotszalk, T. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 170 :7-12