Stability Augmentation of a Grid-Connected Wind Farm by Fuzzy-Logic-Controlled DFIG-Based Wind Turbines

被引:21
|
作者
Hazari, Md. Rifat [1 ]
Mannan, Mohammad Abdul [2 ]
Muyeen, S. M. [3 ]
Umemura, Atsushi [1 ]
Takahashi, Rion [1 ]
Tamura, Junji [1 ]
机构
[1] Kitami Inst Technol KIT, Dept Elect & Elect Engn, 165 Koen Cho, Kitami, Hokkaido 0908507, Japan
[2] Amer Int Univ Bangladesh AIUB, Dept Elect & Elect Engn, Ka 66-1,Kuratoli Rd, Dhaka 1229, Bangladesh
[3] Curtin Univ, Dept Elect & Comp Engn, Perth, WA 6845, Australia
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 01期
关键词
squirrel cage induction generator (SCIG); doubly fed induction generator (DFIG); fuzzy logic controller (FLC); PI controller; low voltage ride through (LVRT); power system; FAULT-RIDE; VOLTAGE; SYSTEMS; CROWBAR; SCHEME;
D O I
10.3390/app8010020
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Wind farm (WF) grid codes require wind generators to have low voltage ride through (LVRT) capability, which means that normal power production should be resumed quickly once the nominal grid voltage has been recovered. However, WFs with fixed-speed wind turbines with squirrel cage induction generators (FSWT-SCIGs) have failed to fulfill the LVRT requirement, which has a significant impact on power system stability. On the other hand, variable-speed wind turbines with doubly fed induction generators (VSWT-DFIGs) have sufficient LVRT augmentation capability and can control the active and reactive power delivered to the grid. However, the DFIG is more expensive than the SCIG due to its AC/DC/AC converter. Therefore, the combined use of SCIGs and DFIGs in a WF could be an effective solution. The design of the rotor-side converter (RSC) controller is crucial because the RSC controller contributes to the system stability. The cascaded control strategy based on four conventional PI controllers is widely used to control the RSC of the DFIG, which can inject only a small amount of reactive power during fault conditions. Therefore, the conventional strategy can stabilize the lower rating of the SCIG. In the present paper, a new control strategy based on fuzzy logic is proposed in the RSC controller of the DFIG in order to enhance the LVRT capability of the SCIG in a WF. The proposed fuzzy logic controller (FLC) is used to control the reactive power delivered to the grid during fault conditions. Moreover, reactive power injection can be increased in the proposed control strategy. Extensive simulations executed in the PSCAD/EMTDC environment for both the proposed and conventional PI controllers of the RSC of the DFIG reveal that the proposed control strategy can stabilize the higher rating of the SCIG.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] A two-stage subsynchronous oscillation assessment method for DFIG-based wind farm grid-connected system
    Liu, Ge
    Liu, Jun
    Liu, Andong
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [22] Impact of Power Grid Strength and PLL Parameters on Stability of Grid-Connected DFIG Wind Farm
    Liu, Ju
    Yao, Wei
    Wen, Jinyu
    Fang, Jiakun
    Jiang, Lin
    He, Haibo
    Cheng, Shijie
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2020, 11 (01) : 545 - 557
  • [23] Stability Analysis of DFIG-based Wind Turbines Based on Hybrid Control in Weak Grid
    Xie Z.
    Xu K.
    Gao X.
    Yang S.
    Zhang X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (20): : 7426 - 7438
  • [24] Detailed Investigation and Performance Improvement of the Dynamic Behavior of Grid-Connected DFIG-Based Wind Turbines Under LVRT Conditions
    Alsmadi, Yazan M.
    Xu, Longya
    Blaabjerg, Frede
    Ortega, Alejandro J. Pina
    Abdelaziz, Almoataz Y.
    Wang, Aimeng
    Albataineh, Zaid
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (05) : 4795 - 4812
  • [25] Dynamic Stability Analysis of a DFIG-Based Offshore Wind Farm Connected to a Power Grid Through an HVDC Link
    Wang, Li
    Wang, Kuo-Hua
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (03) : 1501 - 1510
  • [26] Sub-synchronous resonance analysis of grid-connected DFIG-based wind farms
    Su, Jun-Lin
    Shi, Li-Bao
    Yao, Liang-Zhong
    Ni, Yi-Xin
    Qin, Shi-Yao
    Wang, Rui-Ming
    Zhang, Jin-Ping
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014,
  • [27] Control for grid-connected DFIG-based wind energy system using adaptive neuro-fuzzy technique
    Shihabudheen, K. V.
    Raju, S. Krishnama
    Pillai, G. N.
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2018, 28 (05):
  • [28] LVRT and Stability Enhancement of Grid-Tied Wind Farm Using DFIG-Based Wind Turbine
    Akanto, Jannatul Mawa
    Hazari, Md. Rifat
    Mannan, Mohammad Abdul
    APPLIED SYSTEM INNOVATION, 2021, 4 (02)
  • [29] A Novel Protection Method to Enhance the Grid-Connected Capability of DFIG based on Wind Turbines
    Dai, Le Van
    IETE JOURNAL OF RESEARCH, 2024, 70 (02) : 2047 - 2063
  • [30] Fault Detection and Classification of Grid Connected Wind Farm (DFIG) Using Fuzzy Logic Controller
    Soni, Akash Kumar
    Yadav, Anamika
    2021 IEEE INTERNATIONAL POWER AND RENEWABLE ENERGY CONFERENCE (IPRECON), 2021,