A feasibility study of stereotactic radiosurgery/stereotactic body radiotherapy/stereotactic ablative radiotherapy practice using tomoedge in helical tomotherapy for lung, liver, and spine targets

被引:3
|
作者
Sresty, N. V. N. Madhusudhana [1 ]
Raju, A. Krishnam [1 ]
Kumar, G. Deleep [1 ]
Rohit, S. [1 ]
Reddy, B. Nagarjuna [1 ]
Sahithya, V. C. [1 ]
Reddy, B. Devender [1 ]
Mohd, Yakub [1 ]
Rushdi, Tasneem [1 ]
Bajwa, Harjoth [1 ]
Aparna, S. [2 ]
机构
[1] Basavatarakam Indo Amer Canc Hosp & Res Inst, Dept Radiotherapy, Rd 14,Banjara Hills, Hyderabad 500034, Telangana, India
[2] MNJ Inst Oncol & RCC, Dept Radiotherapy, Hyderabad, Telangana, India
关键词
Stereotactic radiosurgery; stereotactic body radiotherapy; stereotactic ablative radiotherapy; TomoEDGE; TomoTherapy; treatment time; RADIATION-THERAPY; TREATMENT PLANS; CONFORMITY; QUALITY; INDEX;
D O I
10.4103/jmp.JMP_97_20
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The primary purpose of the study is to evaluate the implementation of Helical TomoTherapy (HT) for eligible stereotactic radiosurgery/stereotactic body radiotherapy/stereotactic ablative radiotherapy (SRS/SBRT/SABR) cases using TomoEDGE option. The study focuses on reduction of treatment time without compromise in plan quality using TomoEDGE. It is a mode in HT that uses a dynamic opening of the jaws during treatment delivery to reduce the dose penumbra which otherwise is not possible with fixed jaws option. Eligible SRS/SBRT/SABR cases of lung, liver, and spine were used in this study. All planning parameters such as dose prescription to target and critical organs, pitch, and modulation factor were same in all the plans of the same patient with modifications in the field width and jaw mode. First set of plans with 2.5 cm width and second set of plans with 5 cm width were done in dynamic TomoEDGE mode. Third set of plans created with 5 cm width fixed jaw mode and fourth set of plans with 2.5 cm fixed jaw mode for comparison purpose were done. Our observations achieved that a significant milestone with reduction of up to 34.3% in treatment time of liver cases, 35.2% in lung cases, and 28.7% in spine cases was observed using dynamic TomoEDGE mode with 5 cm width, while no significant variation in the planning results compared with plans using 2.5 cm dynamic TomoEDGE option. TomoEDGE is an efficient and useful mode in TomoTherapy to reduce the treatment time with bigger field width in SRS/SBRT/SABR cases without significant changes in the plan quality.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 50 条
  • [41] Stereotactic ablative body radiotherapy in patients with prostate cancer
    Loblaw, Andrew
    Liu, Stanley
    Cheung, Patrick
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2018, 7 (03) : 330 - 340
  • [42] Prognostic analysis of helical tomotherapy stereotactic body radiotherapy in multiple primary or second primary lung cancers
    Ma, Jintao
    Xu, Xiaohong
    Huang, Wenhan
    Hu, Yong
    Chen, Gang
    He, Jian
    BMC CANCER, 2025, 25 (01)
  • [43] A national dosimetry audit for stereotactic ablative radiotherapy in lung
    Distefano, Gail
    Lee, Jonny
    Jafari, Shakardokht
    Gouldstone, Clare
    Baker, Colin
    Mayles, Helen
    Clark, Catharine H.
    RADIOTHERAPY AND ONCOLOGY, 2017, 122 (03) : 406 - 410
  • [44] The use of RapidArc volumetric-modulated arc therapy to deliver stereotactic radiosurgery and stereotactic body radiotherapy to intracranial and extracranial targets
    Roa, Dante E.
    Schiffner, Daniel C.
    Zhang, Juying
    Dietrich, Salam N.
    Kuo, Jeffrey V.
    Wong, Jason
    Ramsinghani, Nilam S.
    Al-Ghazi, Muthana S. A. L.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 257 - 264
  • [45] Stereotactic ablative radiotherapy for colorectal cancer liver metastasis
    Wang, Hao
    Li, Xuemin
    Peng, Ran
    Wang, Yuxia
    Wang, Junjie
    SEMINARS IN CANCER BIOLOGY, 2021, 71 : 21 - 32
  • [46] Feasibility and tolerability of breath-hold in liver stereotactic body radiotherapy with surface guided radiotherapy
    Turna, Menekse
    Kucukmorkoc, Esra
    Rzazade, Rashad
    Canoglu, Mehmet Dogu
    Kucuk, Nadir
    Caglar, Hale Basak
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2023, 28
  • [47] Feasibility of split-course stereotactic ablative radiotherapy for oligometastases
    Paik, Eun Kyung
    Kim, Mi-Sook
    Seo, Young-Seok
    Jang, Won Il
    Kang, Jin-Kyu
    Cho, Chul-Koo
    Yoo, Hyung Jun
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2018, 48 (06) : 548 - 554
  • [48] Practical patterns for stereotactic body radiotherapy to hepatocellular carcinoma in Korea: a survey of the Korean Stereotactic Radiosurgery Group
    Bae, Sun Hyun
    Kim, Mi-Sook
    Jang, Won Il
    Kay, Chul-Seung
    Kim, Woochul
    Kim, Eun Seog
    Kim, Jin Ho
    Kim, Jin Hee
    Yang, Kwang Mo
    Lee, Kyu Chan
    Chang, A. Ram
    Jo, Sunmi
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2016, 46 (04) : 363 - 369
  • [49] Single fraction spine stereotactic ablative body radiotherapy with volumetric modulated arc therapy
    Gestaut, Matthew M.
    Thawani, Nitika
    Kim, Sangroh
    Gutti, Veera R.
    Jhavar, Sameer
    Deb, Niloyjyoti
    Morrow, Andrew
    Ward, Russell A.
    Huang, Jason H.
    Patel, Mehul
    JOURNAL OF NEURO-ONCOLOGY, 2017, 133 (01) : 165 - 172
  • [50] The RSSearch™ Registry: patterns of care and outcomes research on patients treated with stereotactic radiosurgery and stereotactic body radiotherapy
    Davis, Joanne N.
    Medbery, Clinton, III
    Sharma, Sanjeev
    Danish, Adnan
    Mahadevan, Anand
    RADIATION ONCOLOGY, 2013, 8