Adhesion of new bioactive glass coating

被引:0
作者
Schrooten, J
Van Oosterwyck, H
Vander Sloten, J
Helsen, JA
机构
[1] Katholieke Univ Leuven, Dept Met & Mat Engn, B-3001 Heverlee, Belgium
[2] Katholieke Univ Leuven, Dept Mech, Div Biomech & Engn Design, B-3001 Heverlee, Belgium
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1999年 / 44卷 / 03期
关键词
bioactive glass; coating; plasma spraying; adhesion test; finite element analysis;
D O I
10.1002/(SICI)1097-4636(19990305)44:3<243::AID-JBM2>3.0.CO;2-O
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A valuable alternative to the existing biomedical implant coatings is a bioactive glass (BAG) coating that is produced by reactive plasma spraying. A mechanical performance requirement that is of the utmost importance is the adhesion strength of the coating. Considering the application as dental implant, a new adhesion test (shear test), which was close to the service conditions, was designed. A Ti6A14V rod (O3 mm) with a sprayed BAG coating of 50 mu m was glued with an epoxy glue to a hollow cylindrical counterpart and was used as such in the tensile machine. This test was evaluated by finite element analysis (FEA). Preliminary experiments showed that a conversion from shear to tensile adhesion strength is possible by using the Von Mises criterion (sigma = 3(1/2)tau), indicating that thin coatings of brittle materials can behave as a ductile material. The new coating technique was proved to produce a high quality coating with an adhesion strength of 40.1 +/- 4.8 MPa in shear and 69.4 +/- 8.4 MPa in tension. The FEA revealed that no one homogeneously distributed shear stress is present but several nonhomogeneously distributed stress components (shear and tensile) are present in the coating. This analysis indicated that real service conditions are much more complicated than standard adhesion tests. (C) 1999 John Wiley & Sons, Inc.
引用
收藏
页码:243 / 252
页数:10
相关论文
共 26 条
[1]  
AMBROZ O, 1992, P INT THERM SPRAY C, P921
[2]  
[Anonymous], 1990, MET HDB, V1, P871
[3]  
*ASM INT, 1990, MET HDB, V1, P621
[4]  
*ASTM, 1995, C116194 ASTM
[5]  
*ASTM, 1995, C125994 ASTM
[6]  
Bansal N. P., 1986, HDB GLASS PROPERTIES
[7]   BIOACTIVE GLASS CERAMIC ON TITANIUM SUBSTRATE - THE EFFECT OF MOLYBDENUM AS AN INTERMEDIATE BOND COATING [J].
BARTH, E ;
HERO, H .
BIOMATERIALS, 1986, 7 (04) :273-276
[8]   TENSILE ADHESION TESTING METHODOLOGY FOR THERMALLY SPRAYED COATINGS [J].
BERNDT, CC .
JOURNAL OF MATERIALS ENGINEERING, 1990, 12 (02) :151-158
[9]   MEASUREMENT OF ADHESION FOR THERMALLY SPRAYED MATERIALS [J].
BERNDT, CC ;
LIN, CK .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 1993, 7 (12) :1235-1264
[10]  
BERNDT CC, 1992, P INT THERM SPRAY C, P45