Bond strength between substrate and post-cast UHPC with innovative interface treatment

被引:21
作者
Lu, Kaiwei [1 ,2 ]
Pang, Zhiming [1 ,2 ]
Xu, Qizhi [1 ,2 ]
Yao, Yiming [1 ,2 ]
Wang, Jingquan [1 ,2 ]
Miao, Changwen [2 ,3 ]
机构
[1] Southeast Univ, Sch Civil Engn, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Nanjing 210096, Peoples R China
[2] Southeast Univ, Bridge Engn Res Ctr, Nanjing 210096, Peoples R China
[3] Southeast Univ, Sch Mat Sci & Engn, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Ultra -high performance concrete (UHPC); Bond performance; Steel wire mesh (SWM) treatment; Fiber bridging; OLD CONCRETE SUBSTRATE; FIBER CONTENT; PERFORMANCE; ROUGHNESS; BEHAVIOR; MICROSTRUCTURE; ADHESION; STRAIGHT;
D O I
10.1016/j.cemconcomp.2022.104691
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ultra-high performance concrete (UHPC) has been utilized in construction joint by virtue of superior strength, crack resistance and durability. However, fiber bridging at the interface between substrate UHPC and post-cast UHPC is limited in current engineering practices, which may lead to the loss of various performances. The objective of the present research is to identify the bond performance of the UHPC-UHPC interface bridged by the steel fibers, using different surface treatment techniques including chipping and steel wire mesh (SWM) pre-treatment. To this end, direct tensile tests, direct shear tests and slant shear tests were carried out on the specimens with no treatment, chipping and SWM treatment. The experimental results show that SWM treatment can greatly play the role of fiber bridging at the interface, thus increasing the tensile and shear bond strengths by 55.3% and 333.3%, respectively, compared with interfaces without treatment. The calculation model of the interfacial bond tensile strength and shear strength considering the effect of the fiber bridging was established. Furthermore, conversion of bond tests between tension and shear was discussed, and linear transformation relationship was found among direct tensile tests, direct shear tests and slant shear tests.
引用
收藏
页数:11
相关论文
共 60 条
  • [1] American Association of State Highway and Transportation Officials, 2020, AASHTO LRFD BRIDG CO
  • [2] [Anonymous], 2016, CONCRETE SUBSTRATE M
  • [3] [Anonymous], 2016, P18710 NF ASS FRANC
  • [4] [Anonymous], 2009, CECS132009, P64
  • [5] Influence of substrate moisture state and roughness on interface microstructure and bond strength: Slant shear vs. pull-off testing
    Bentz, Dale P.
    De la Varga, Igor
    Munoz, Jose F.
    Spragg, Robert P.
    Graybeal, Benjamin A.
    Hussey, Daniel S.
    Jacobson, David L.
    Jones, Scott Z.
    LaManna, Jacob M.
    [J]. CEMENT & CONCRETE COMPOSITES, 2018, 87 : 63 - 72
  • [7] The influence of substrate moisture preparation on bond strength of concrete overlays and the microstructure of the OTZ
    Beushausen, Hans
    Hohlig, Bjorn
    Talotti, Marco
    [J]. CEMENT AND CONCRETE RESEARCH, 2017, 92 : 84 - 91
  • [8] Bissonnette B., 2012, Best practices for preparing concrete surfaces prior to repairs and overlays
  • [9] Bissonnette B., 2017, DEV SPECIFICATIONS P