The challenge of bias-free coil combination for quantitative susceptibility mapping at ultra-high field

被引:14
作者
Bollmann, Steffen [1 ]
Robinson, Simon Daniel [2 ]
O'Brien, Kieran [1 ,3 ]
Vegh, Viktor [1 ]
Janke, Andrew [1 ]
Marstaller, Lars [1 ]
Reutens, David [1 ]
Barth, Markus [1 ]
机构
[1] Univ Queensland, Ctr Adv Imaging, Bldg 57,Res Rd, Brisbane, Qld 4072, Australia
[2] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, High Field Magnet Resonance Ctr, Vienna, Austria
[3] Siemens Healthcare Pty Ltd, Brisbane, Qld, Australia
基金
澳大利亚研究理事会;
关键词
COMPOSER; 3D EPI; ultra-high field; QSM; PETRA; atlas-based segmentation; PHASE IMAGES; CHANNEL COMBINATION; MR-VENOGRAPHY; BRAIN IRON; ROBUST; CONTRAST; RECONSTRUCTION; OPTIMIZATION; REGISTRATION; MICROBLEEDS;
D O I
10.1002/mrm.26644
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeQuantitative susceptibility mapping is a technique to estimate the magnetic property of tissue with particularly high sensitivity at ultra-high field. However, a key challenge at ultra-high field is the combination of phase data acquired using phased array receive coils. Several methods for combining phase data have been proposed, but the influence of coil combination choices on susceptibility quantitation has not been studied systematically. MethodsWe combined phase data using COMPOSER (COMbining Phase data using a Short Echo-time Reference scan) and a reference-free channel-by-channel method. We investigated the effect of the chosen combination method on susceptibility results in a group of 28 participants at 7 Tesla. ResultsOur results show that reference scans can bias susceptibility values. Although the proposed reference-free channel-by-channel method cannot remove transmit field phase, it shows comparable results to the COMPOSER method in which a high-resolution ultrashort echo-time reference scan was used. ConclusionsWe conclude that ultrashort echo-time reference scans reduce quantitation bias and remove the transmit field phase when using COMPOSER to combine phase data, and not combining the phase data before susceptibility processing avoids this bias, resulting in comparable results. Magn Reson Med 79:97-107, 2018. (c) 2017 InternationalSociety for Magnetic Resonance in Medicine.
引用
收藏
页码:97 / 107
页数:11
相关论文
共 57 条
  • [1] In Vivo MRI Mapping of Brain Iron Deposition across the Adult Lifespan
    Acosta-Cabronero, Julio
    Betts, Matthew J.
    Cardenas-Blanco, Arturo
    Yang, Shan
    Nestor, Peter J.
    [J]. JOURNAL OF NEUROSCIENCE, 2016, 36 (02) : 364 - 374
  • [2] In Vivo Quantitative Susceptibility Mapping (QSM) in Alzheimer's Disease
    Acosta-Cabronero, Julio
    Williams, Guy B.
    Cardenas-Blanco, Arturo
    Arnold, Robert J.
    Lupson, Victoria
    Nestor, Peter J.
    [J]. PLOS ONE, 2013, 8 (11):
  • [3] RECONSTRUCTIONS OF PHASE-CONTRAST, PHASED-ARRAY MULTICOIL DATA
    BERNSTEIN, MA
    GRGIC, M
    BROSNAN, TJ
    PELC, NJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 330 - 334
  • [4] MRI estimates of brain iron concentration in normal aging using quantitative susceptibility mapping
    Bilgic, Berkin
    Pfefferbaum, Adolf
    Rohlfing, Torsten
    Sullivan, Edith V.
    Adalsteinsson, Elfar
    [J]. NEUROIMAGE, 2012, 59 (03) : 2625 - 2635
  • [5] Bollmann S, 2015, P 21 ANN M ORG HUM B
  • [6] Buehrer M, 2009, P 17 ANN M ISMRM HON, P759
  • [7] Array compression for MRI with large coil arrays
    Buehrer, Martin
    Pruessmann, Klaas P.
    Boesiger, Peter
    Kozerke, Sebastian
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) : 1131 - 1139
  • [8] MAGPI: A framework for maximum likelihood MR phase imaging using multiple receive coils
    Dagher, Joseph
    Nael, Kambiz
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1218 - 1231
  • [9] A Gradual Increase of Iron Toward the Medial-Inferior Tip of the Subthalamic Nucleus
    de Hollander, Gilles
    Keuken, Max C.
    Bazin, Pierre-Louis
    Weiss, Marcel
    Neumann, Jane
    Reimann, Katja
    Waehnert, Miriam
    Turner, Robert
    Forstmann, Birte U.
    Schaefer, Andreas
    [J]. HUMAN BRAIN MAPPING, 2014, 35 (09) : 4440 - 4449
  • [10] MR susceptibility imaging
    Duyn, Jeff
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2013, 229 : 198 - 207