Sutureless 27-gauge needle-assisted transconjunctival intrascleral intraocular lens fixation: Initial experience

被引:45
|
作者
Kelkar, Aditya Shrikant [1 ]
Fogla, Rajesh [2 ]
Kelkar, Jai [1 ]
Kothari, Akshay Anil [1 ]
Mehta, Hetal [1 ]
Amoaku, Winfried [3 ]
机构
[1] Natl Inst Ophthalmol, Dept Ophthalmol, Pune, Maharashtra, India
[2] Apollo Hlth City, Dept Ophthalmol, Hyderabad, Telangana, India
[3] Univ Nottingham, Dept Ophthalmol, Nottingham, England
关键词
Endothelial cell density; intraocular pressure; macular thickness; modified Yamane's double-needle technique and flanged haptics; transconjunctival intrascleral intraocular lens fixation; visual outcomes; CHAMBER; IMPLANTATION; EYES; IOL;
D O I
10.4103/ijo.IJO_659_17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of the study was to report our initial experience with the transconjunctival Intrascleral Intraocular Lens (SFIOL) fixation with modified Yamane's double-needle technique and flanged haptics. Methods: This was a prospective interventional study that enrolled 31 consecutive patients undergoing SFIOL with the modified Yamane's technique. All patients underwent comprehensive evaluation including uncorrected and best-corrected vision, intraocular pressure, ultrasound biomicroscopy, endothelial cell density, and macular thickness using optical coherence tomography (OCT). We excluded patients with visually significant coexistent pathology such as corneal scars, macular pathology, and glaucoma. Results: The mean age of subjects was 57 +/- 16.9 years and 23 were men (74%). Surgery was performed for aphakia following complicated cataract surgery in 10 eyes (32%), with lensectomy for subluxated/dislocated cataract in 6 eyes (19%), and with IOL explantation for subluxated/dislocated IOL in 15 eyes (48%). There were no intraoperative complications. Uncorrected visual acuity improved from median of 1.48 logarithm of minimum angle of resolution (logMAR) units (interquartile range [IQR] = 1.3-2 logMAR) at baseline to 0.3 logMAR (IQR = 0.2-0.4 logMAR) at 6 weeks (P < 0.001) which was maintained at 6 months. There were no significant changes in endothelial cell density (P = 0.34) and OCT-based macular thickness (P = 0.31) at 6 months. Two eyes had slight IOL decentration. Conclusion: Our initial experience suggests that the Yamane's technique for SFIOL is a simple procedure with a short-learning curve and is independent of scleral flaps, tunnels, sutures, and fibrin glue. Using widely available 27-gauge needle instead of 30-gauge thin wall needle as originally described by Yamane makes it possible for the use of various three-piece IOLs available globally. Further studies are required for widespread acceptance of this technique.
引用
收藏
页码:1450 / 1453
页数:4
相关论文
共 50 条
  • [21] Safety, efficacy, and clinical outcomes of transconjunctival intrascleral fixation of an intraocular lens
    Aljindan, Mohanna
    Hamdi, Abdu
    Alali, Naif Mamdouh
    Hashem, Faris
    AlBalawi, Hani Basher
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [22] Flapless and sutureless intrascleral fixation of posterior chamber intraocular lens for correction of aphakia
    Can, Ertugrul
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (08): : 929 - 931
  • [23] COMPARISON OF SCLERAL FIXATION OF INTRAOCULAR LENS Sutureless Intrascleral Fixation Versus Conventional Sutured Scleral Fixation
    Jang, Kyu Hwan
    Kong, Mingui
    Moon, Byung Gil
    Son, Gisung
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (04): : 761 - 767
  • [24] Intraocular Lens Formula Comparison of Flanged Intrascleral Intraocular Lens Fixation with Double Needle Technique
    Malach, Daniel S.
    Guest, John Michael
    Adam, Christopher
    Joffe, Jonah
    Le, Kim
    Kim, Chaesik
    Lin, Xihui
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 837 - 842
  • [25] Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation
    Scharioth, Gabor B.
    Prasad, Som
    Georgalas, Ilias
    Tataru, Calin
    Pavlidis, Mitrofanis
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (02): : 254 - 259
  • [26] Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique
    Yamane, Shin
    Sato, Shimpei
    Maruyama-Inoue, Maiko
    Kadonosono, Kazuaki
    OPHTHALMOLOGY, 2017, 124 (08) : 1136 - 1142
  • [27] Bioptics in Sutureless Intrascleral Multifocal Posterior Chamber Intraocular Lens Fixation
    Pavlidis, Mitrofanis
    de Ortueta, Diego
    Scharioth, Gabor B.
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (05) : 386 - 388
  • [28] Motorized injector-assisted intrascleral intraocular lens fixation
    Hung, Jia-Horung
    Wang, Shih-Hao
    Teng, Yu-Ti
    Hsu, Sheng-Min
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2017, 33 (03): : 137 - 143
  • [29] Trocar-assisted intrascleral sutureless fixation of a dislocated three-piece sulcus intraocular lens
    Karadag, Remzi
    Gunes, Bahar
    Demiorok, Ahmet
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (06) : 393 - 395
  • [30] Sutureless glueless intrascleral fixation of posterior chamber intraocular lens: Boon for aphakic
    Shekhawat, Nagendra
    Goyal, Karishma
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) : 1454 - 1458