Sutureless 27-gauge needle-assisted transconjunctival intrascleral intraocular lens fixation: Initial experience

被引:45
|
作者
Kelkar, Aditya Shrikant [1 ]
Fogla, Rajesh [2 ]
Kelkar, Jai [1 ]
Kothari, Akshay Anil [1 ]
Mehta, Hetal [1 ]
Amoaku, Winfried [3 ]
机构
[1] Natl Inst Ophthalmol, Dept Ophthalmol, Pune, Maharashtra, India
[2] Apollo Hlth City, Dept Ophthalmol, Hyderabad, Telangana, India
[3] Univ Nottingham, Dept Ophthalmol, Nottingham, England
关键词
Endothelial cell density; intraocular pressure; macular thickness; modified Yamane's double-needle technique and flanged haptics; transconjunctival intrascleral intraocular lens fixation; visual outcomes; CHAMBER; IMPLANTATION; EYES; IOL;
D O I
10.4103/ijo.IJO_659_17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of the study was to report our initial experience with the transconjunctival Intrascleral Intraocular Lens (SFIOL) fixation with modified Yamane's double-needle technique and flanged haptics. Methods: This was a prospective interventional study that enrolled 31 consecutive patients undergoing SFIOL with the modified Yamane's technique. All patients underwent comprehensive evaluation including uncorrected and best-corrected vision, intraocular pressure, ultrasound biomicroscopy, endothelial cell density, and macular thickness using optical coherence tomography (OCT). We excluded patients with visually significant coexistent pathology such as corneal scars, macular pathology, and glaucoma. Results: The mean age of subjects was 57 +/- 16.9 years and 23 were men (74%). Surgery was performed for aphakia following complicated cataract surgery in 10 eyes (32%), with lensectomy for subluxated/dislocated cataract in 6 eyes (19%), and with IOL explantation for subluxated/dislocated IOL in 15 eyes (48%). There were no intraoperative complications. Uncorrected visual acuity improved from median of 1.48 logarithm of minimum angle of resolution (logMAR) units (interquartile range [IQR] = 1.3-2 logMAR) at baseline to 0.3 logMAR (IQR = 0.2-0.4 logMAR) at 6 weeks (P < 0.001) which was maintained at 6 months. There were no significant changes in endothelial cell density (P = 0.34) and OCT-based macular thickness (P = 0.31) at 6 months. Two eyes had slight IOL decentration. Conclusion: Our initial experience suggests that the Yamane's technique for SFIOL is a simple procedure with a short-learning curve and is independent of scleral flaps, tunnels, sutures, and fibrin glue. Using widely available 27-gauge needle instead of 30-gauge thin wall needle as originally described by Yamane makes it possible for the use of various three-piece IOLs available globally. Further studies are required for widespread acceptance of this technique.
引用
收藏
页码:1450 / 1453
页数:4
相关论文
共 50 条
  • [11] Refractive errors after sutureless intrascleral fixation of intraocular lens
    Kakisu, Masato
    Baba, Takayuki
    Tatsumi, Tomoaki
    Iwase, Takehito
    Nizawa, Tomohiro
    Miura, Gen
    Yamamoto, Shuichi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (10) : 3003 - 3009
  • [12] Management of complications of sutureless intrascleral intraocular lens fixation
    Cheng, Chia-Yi
    Chou, Yu-Bai
    Tsai, Chia-Ying
    Hsieh, Ming-Hung
    Hsiao, Chia-Chieh
    Lai, Tso-Ting
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2024, 14 (01) : 95 - 101
  • [13] Sutureless Intrascleral Intraocular Lens Fixation Using a Microtube-Assisted Technique
    Yuda, Kentaro
    Shimizu, Toshiki
    Hayashi, Takahiko
    Yuda, Kenji
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 39 - 43
  • [14] Exposure of haptic of posterior chamber intraocular lens after sutureless intrascleral fixation
    Matsui, Yoshitsugu
    Matsubara, Hisashi
    Hanemoto, Tsukasa
    Kondo, Mineo
    BMC OPHTHALMOLOGY, 2015, 15
  • [15] A modified intrascleral intraocular lens fixation technique with fewer anterior segment manipulations: 27-gauge needle-guided procedure with built-in 8-0 absorbable sutures
    Yang, Yuan
    Yao, Teng-teng
    Zhou, Ya-li
    Wang, Yi-xiao
    Wang, Zhao-yang
    BMC OPHTHALMOLOGY, 2019, 19 (01)
  • [16] Surgical Technique for Sutureless Intrascleral Fixation of a 3-Piece Intraocular Lens Using a 30-Gauge Needle
    Bonnell, Alyssa C.
    Mantopoulos, Dimosthenis
    Wheatley, H. Matthew
    Prenner, Jonathan L.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 13 - 15
  • [17] 27-GAUGE SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENSES WITH HAPTIC FLANGING Short-Term Clinical Outcomes and a Disinsertion Force Study
    Stem, Maxwell S.
    Wa, Christianne A.
    Todorich, Bozho
    Woodward, Maria A.
    Walsh, Mark K.
    Wolfe, Jeremy D.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (11): : 2149 - 2154
  • [18] Surgical outcomes and complications of sutureless needle-guided intrascleral intraocular lens fixation combined with vitrectomy
    Shelke, Komal
    Rishi, Ekta
    Rishi, Pukhraj
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (09) : 2317 - 2320
  • [19] Endoscope-Assisted Sutureless Intrascleral Haptic Fixation of a Posterior Chamber Intraocular Lens
    Tandias, Rachel
    Lemire, Colin A.
    Yu, Gina
    Seto, Brendan
    Arroyo, Jorge G.
    JOURNAL OF VITREORETINAL DISEASES, 2022, 6 (04) : 290 - 294
  • [20] Sutureless intrascleral fixation using a uniquely designed intraocular lens
    Colantuono, D.
    Seknazi, D.
    Miere, A.
    Amoroso, F.
    Glacet-Bernard, A.
    Souied, E. H.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (07): : 957 - 961