Steady-state MR imaging sequences: Physics, classification, and clinical applications

被引:199
作者
Chavhan, Govind B. [1 ,2 ]
Babyn, Paul S. [1 ,2 ]
Jankharia, Bhavin G. [3 ]
Cheng, Hai-Ling M. [1 ,2 ]
Shroff, Manohar M. [1 ,2 ]
机构
[1] Hosp Sick Children, Dept Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Toronto, ON M5G 1X8, Canada
[3] Jankharia Imaging Ctr, Mumbai, Maharashtra, India
关键词
D O I
10.1148/rg.284075031
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Steady-state sequences are a class of rapid magnetic resonance (MR) imaging techniques based on fast gradient-echo acquisitions in which both longitudinal magnetization (LM) and transverse magnetization (TM) are kept constant. Both LM and TM reach a nonzero steady state through the use of a repetition time that is shorter than the T2 relaxation time of tissue. When TM is maintained as multiple radio-frequency excitation pulses are applied, two types of signal are formed once steady state is reached: preexcitation signal (S-) from echo reformation; and postexcitation signal (S+), which consists of free induction decay. Depending on the signal sampled and used to form an image, steady-state sequences can be classified as (a) postexcitation refocused (only S+ is sampled), (b) preexcitation refocused (only S- is sampled), and (c) fully refocused (both S+ and S- are sampled) sequences. All tissues with a reasonably long T2 relaxation time will show additional signals due to various refocused echo paths. Steady-state sequences have revolutionized cardiac imaging and have become the standard for anatomic functional cardiac imaging and for the assessment of myocardial viability because of their good signal-to-noise ratio and contrast-to-noise ratio and increased speed of acquisition. They are also useful in abdominal and fetal imaging and hold promise for interventional MR imaging. Because steady-state sequences are now commonly used in MR imaging, radiologists will benefit from understanding the underlying physics, classification, and clinical applications of these sequences. (C) RSNA, 2008.
引用
收藏
页码:1147 / 1160
页数:14
相关论文
共 42 条
[21]  
Hoffmann KT, 2000, AM J NEURORADIOL, V21, P493
[22]   3D steady-state MR cisternography in CSF rhinorrhoea [J].
Jayakumar, PN ;
Kovoor, JME ;
Srikanth, SG ;
Praharaj, SS .
ACTA RADIOLOGICA, 2001, 42 (06) :582-584
[23]   Technologic advances in abdominal MR imaging [J].
Keogan, MT ;
Edelman, RR .
RADIOLOGY, 2001, 220 (02) :310-320
[24]  
Kordesch KV, 2006, CLIN MAGNETIC RESONA, P23
[25]  
Lane JI, 2004, AM J NEURORADIOL, V25, P618
[26]   Real-time cardiac cine imaging with SPIDER: Steady-state projection imaging with dynamic echo-train readout [J].
Larson, AC ;
Simonetti, OP .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1059-1066
[27]   Magnetic resonance angiography of coronary arteries with a 3-dimensional magnetization-prepared true fast imaging with steady-state precession sequence compared with conventional coronary angiography [J].
Man-ching, N ;
Lam, WW ;
Li, D ;
Chan, AK ;
Sanderson, JE ;
Metreweli, C .
AMERICAN HEART JOURNAL, 2005, 150 (03) :530-535
[28]  
Martin Diego R, 2005, Top Magn Reson Imaging, V16, P77, DOI 10.1097/01.rmr.0000179461.55234.7d
[29]  
NISHIMURA DG, 2000, P 8 ANN M ISMRM DENV, P301
[30]   MR imaging: acronyms and clinical applications [J].
Nitz, WR .
EUROPEAN RADIOLOGY, 1999, 9 (05) :979-997