Does the Type of Intrauterine Device Affect Conspicuity on 2D and 3D Ultrasound?

被引:24
作者
Moschos, Elysia [1 ]
Twickler, Diane M. [1 ,2 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Obstet & Gynecol, Div Gynecol, Dallas, TX 75390 USA
[2] Univ Texas SW Med Ctr Dallas, Dept Radiol, Dallas, TX 75390 USA
关键词
2D ultrasound; 3D ultrasound; copper intrauterine device; intrauterine device; levonorgestrel-releasing intrauterine system; Mirena; 3-DIMENSIONAL ULTRASOUND; CONTRACEPTIVE-DEVICES; SONOGRAPHY;
D O I
10.2214/AJR.10.5483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to assess the conspicuity and position evaluation of intrauterine devices (IUDs) on 2D ultrasound and 3D ultrasound in nongravid patients. MATERIALS AND METHODS. Review of the ultrasound database for the period from July 2008 through June 2009 was performed for identification of patients with IUDs, of the type and position of the IUD, and of the patient's presenting symptoms. The conspicuity of the IUD on 2D sagittal and transverse planes and 3D coronal views was scored according to a 7-point scale. Data analysis was performed using the Student t test and the Pearson chi-square test. RESULTS. Of the 269 patients with IUDs who had undergone ultrasound during the study period, 180 patients had a copper IUD; 59, a levonorgestrel-releasing device; and three, a Lippes loop. Twenty-seven IUDs were excluded because they were not seen on ultrasound (n = 15) or the type of IUD was not identifiable (n = 12). Of the 239 IUDs identified, the conspicuity score for copper IUDs (mean score, 5.3 [SD, 1.4]) differed significantly from that for levonorgestrel-releasing IUDs (mean, 3.1 [1.0]) on 2D ultrasound (p < 0.001). The difference in the conspicuity score for copper IUDs (mean, 6.6 [0.95]) versus that for levonorgestrel-releasing devices (mean, 6.2 [0.92]) on 3D ultrasound was marginally significant (p = 0.05). One hundred seventy-six IUDs (74%) were properly positioned within the endometrial cavity and 60 (25%) were malpositioned; proper positioning of three IUDs (1%) could not be confirmed. The indications for sonographic evaluation were pain (111/239, 46%), missing strings (91/239, 38%), and bleeding (34/239, 14%). Of the patients who presented with bleeding, the IUD was malpositioned in 13 (38%). CONCLUSION. The levonorgestrel-releasing IUD is significantly less conspicuous than the copper IUD on 2D imaging. Three-dimensional ultrasound enhances the conspicuity of both types of IUD.
引用
收藏
页码:1439 / 1443
页数:5
相关论文
共 50 条
  • [31] Detection of Subpubic Tumor Causing Bladder Outlet Obstruction by 3D Perineal Ultrasound
    Albrich, S.
    Steetskamp, J.
    Rommens, K.
    Porta, S.
    Battista, M.
    Hoffmann, G.
    Skala, C.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2015, 75 (07) : 719 - 722
  • [32] Study of Intraplacental Vascularization by 3D Power Doppler Ultrasound in Pregnancies with Normal Evolution
    Mihu, Carmen Mihaela
    Mihu, Dan
    Drugan, Tudor
    Dudea, Sorin
    Ciortea, Razvan
    Oancea, Mihaela
    GINECO RO, 2010, 6 (04): : 210 - 216
  • [33] Design and Characterization of Carboplatin and Paclitaxel Loaded PCL Filaments for 3D Printed Controlled Release Intrauterine Implants
    Varan, Cem
    Aksut, Davut
    Sen, Murat
    Bilensoy, Erem
    PHARMACEUTICS, 2023, 15 (04)
  • [34] Correlation of intrapartum translabial ultrasound parameters with computed tomographic 3D reconstruction of the female pelvis
    Armbrust, Robert
    Henrich, Wolfgang
    Hinkson, Larry
    Grieser, Christian
    Siedentopf, Jan-Peter
    JOURNAL OF PERINATAL MEDICINE, 2016, 44 (05) : 567 - 571
  • [35] Automated 3D whole-breast ultrasound imaging: results of a clinical pilot study
    Leproux, Anais
    van Beek, Michiel
    de Vries, Ute
    Wasser, Martin
    Bakker, Leon
    Cuisenaire, Olivier
    van der Mark, Martin
    Entrekin, Rob
    MEDICAL IMAGING 2010: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2010, 7629
  • [36] Radiologists' performance in the detection of benign and malignant masses with 3D automated breast ultrasound (ABUS)
    Chang, Jung Min
    Moon, Woo Kyung
    Cho, Nariya
    Park, Jeong Seon
    Kim, Seung Ja
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (01) : 99 - 103
  • [37] A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results
    Schulz-Wendtland, Ruediger
    Jud, Sebastian M.
    Fasching, Peter A.
    Hartmann, Arndt
    Radicke, Marcus
    Rauh, Claudia
    Uder, Michael
    Wunderle, Marius
    Gass, Paul
    Langemann, Hanna
    Beckmann, MatthiasW.
    Emons, Julius
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2017, 77 (06) : 679 - 685
  • [38] Does 3D imaging of the fetal spine improve confidence in interpreting images in the second trimester?
    Harding, Catherine M. L.
    Davies, Braidy
    Cowell, Simon F. F.
    Saxton, Virginia
    Choong, Shawn
    Strainge, John
    SONOGRAPHY, 2023, 10 (03) : 107 - 117
  • [39] Usefulness of 3D transperineal ultrasound in severe stenosis of the anal canal: preliminary experience in four cases
    Kolodziejczak, M.
    Santoro, G. A.
    Slapa, R. Z.
    Szopinski, T.
    Sudol-Szopinska, I.
    TECHNIQUES IN COLOPROCTOLOGY, 2014, 18 (05) : 495 - 501
  • [40] 3D intra-operative ultrasound and MR image guidance: pursuing an ultrasound-based management of brainshift to enhance neuronavigation
    Riva, Marco
    Hennersperger, Christoph
    Milletari, Fausto
    Katouzian, Amin
    Pessina, Federico
    Gutierrez-Becker, Benjamin
    Castellano, Antonella
    Navab, Nassir
    Bello, Lorenzo
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (10) : 1711 - 1725