Does the Type of Intrauterine Device Affect Conspicuity on 2D and 3D Ultrasound?

被引:24
作者
Moschos, Elysia [1 ]
Twickler, Diane M. [1 ,2 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Obstet & Gynecol, Div Gynecol, Dallas, TX 75390 USA
[2] Univ Texas SW Med Ctr Dallas, Dept Radiol, Dallas, TX 75390 USA
关键词
2D ultrasound; 3D ultrasound; copper intrauterine device; intrauterine device; levonorgestrel-releasing intrauterine system; Mirena; 3-DIMENSIONAL ULTRASOUND; CONTRACEPTIVE-DEVICES; SONOGRAPHY;
D O I
10.2214/AJR.10.5483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to assess the conspicuity and position evaluation of intrauterine devices (IUDs) on 2D ultrasound and 3D ultrasound in nongravid patients. MATERIALS AND METHODS. Review of the ultrasound database for the period from July 2008 through June 2009 was performed for identification of patients with IUDs, of the type and position of the IUD, and of the patient's presenting symptoms. The conspicuity of the IUD on 2D sagittal and transverse planes and 3D coronal views was scored according to a 7-point scale. Data analysis was performed using the Student t test and the Pearson chi-square test. RESULTS. Of the 269 patients with IUDs who had undergone ultrasound during the study period, 180 patients had a copper IUD; 59, a levonorgestrel-releasing device; and three, a Lippes loop. Twenty-seven IUDs were excluded because they were not seen on ultrasound (n = 15) or the type of IUD was not identifiable (n = 12). Of the 239 IUDs identified, the conspicuity score for copper IUDs (mean score, 5.3 [SD, 1.4]) differed significantly from that for levonorgestrel-releasing IUDs (mean, 3.1 [1.0]) on 2D ultrasound (p < 0.001). The difference in the conspicuity score for copper IUDs (mean, 6.6 [0.95]) versus that for levonorgestrel-releasing devices (mean, 6.2 [0.92]) on 3D ultrasound was marginally significant (p = 0.05). One hundred seventy-six IUDs (74%) were properly positioned within the endometrial cavity and 60 (25%) were malpositioned; proper positioning of three IUDs (1%) could not be confirmed. The indications for sonographic evaluation were pain (111/239, 46%), missing strings (91/239, 38%), and bleeding (34/239, 14%). Of the patients who presented with bleeding, the IUD was malpositioned in 13 (38%). CONCLUSION. The levonorgestrel-releasing IUD is significantly less conspicuous than the copper IUD on 2D imaging. Three-dimensional ultrasound enhances the conspicuity of both types of IUD.
引用
收藏
页码:1439 / 1443
页数:5
相关论文
共 50 条
  • [21] Application of 3D and 2D quantitative shear wave elastography (SWE) to differentiate between benign and malignant breast masses
    Tian, Jie
    Liu, Qianqi
    Wang, Xi
    Xing, Ping
    Yang, Zhuowen
    Wu, Changjun
    SCIENTIFIC REPORTS, 2017, 7
  • [22] Contribution of 3D power Doppler ultrasound to the evaluation of fetoplacental circulation
    Mihu, Carmen Mihaela
    Mihu, D.
    Costin, N.
    Dudea, S.
    Oancea, Mihaela
    Ciortea, R.
    GINECO RO, 2009, 5 (04): : 224 - 228
  • [23] Prenatal Demonstration of Normal Variants of the Pericallosal Artery by 3D Ultrasound
    Pashaj, S.
    Merz, E.
    ULTRASCHALL IN DER MEDIZIN, 2014, 35 (02): : 129 - 136
  • [24] Clinical Significance of 3D Ultrasound Compared to MRI in Uterine Malformations
    Imboden, S.
    Mueller, M.
    Raio, L.
    Mueller, M. D.
    Tutschek, B.
    ULTRASCHALL IN DER MEDIZIN, 2014, 35 (05): : 440 - 444
  • [25] Detection of Fetal Corpus Callosum Abnormalities by Means of 3D Ultrasound
    Pashaj, S.
    Merz, E.
    ULTRASCHALL IN DER MEDIZIN, 2016, 37 (02): : 185 - 194
  • [26] Analysis of linear, area and volume distortion in 3D ultrasound imaging
    Tong, S
    Cardinal, HN
    Downey, DB
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (03) : 355 - 373
  • [27] Could a 2D/3D US based model be helpful in the assessment of myometrial invasion at time of intraoperative frozen section? A pilot study
    Ferrero, Annamaria
    Novara, Lorenzo
    Perotto, Stefania
    Capece, Roberto
    Petey, Francesca
    Perrini, Gaetano
    Mariani, Luca L.
    de Rosa, Giovanni
    Biglia, Nicoletta
    Fuso, Luca
    MINERVA OBSTETRICS AND GYNECOLOGY, 2021, 73 (03) : 362 - 368
  • [28] 25 Years of 3D Ultrasound in Prenatal Diagnosis (1989-2014)
    Merz, E.
    ULTRASCHALL IN DER MEDIZIN, 2015, 36 (01): : 3 - 8
  • [29] Diagnostic value of 3D power Doppler ultrasound in the characterization of thyroid nodules
    Cansu, Aysegul
    Ayan, Emin
    Kul, Sibel
    Eyuboglu, Ilker
    Oguz, Sukru
    Mungan, Sevdegul
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2019, 49 (03) : 723 - 729
  • [30] Realization of automated whole breast 3D Doppler ultrasound for characterization of breast lesions
    Aziz, Amal
    Rahman, R. Abdul
    Park, C. K.
    Trumpour, T.
    Bax, J.
    Gardi, L.
    Tessier, D.
    Barker, K.
    Poepping, T.
    Fenster, A.
    MEDICAL IMAGING 2024: ULTRASONIC IMAGING AND TOMOGRAPHY, 2024, 12932