Does the Type of Intrauterine Device Affect Conspicuity on 2D and 3D Ultrasound?

被引:24
|
作者
Moschos, Elysia [1 ]
Twickler, Diane M. [1 ,2 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Obstet & Gynecol, Div Gynecol, Dallas, TX 75390 USA
[2] Univ Texas SW Med Ctr Dallas, Dept Radiol, Dallas, TX 75390 USA
关键词
2D ultrasound; 3D ultrasound; copper intrauterine device; intrauterine device; levonorgestrel-releasing intrauterine system; Mirena; 3-DIMENSIONAL ULTRASOUND; CONTRACEPTIVE-DEVICES; SONOGRAPHY;
D O I
10.2214/AJR.10.5483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to assess the conspicuity and position evaluation of intrauterine devices (IUDs) on 2D ultrasound and 3D ultrasound in nongravid patients. MATERIALS AND METHODS. Review of the ultrasound database for the period from July 2008 through June 2009 was performed for identification of patients with IUDs, of the type and position of the IUD, and of the patient's presenting symptoms. The conspicuity of the IUD on 2D sagittal and transverse planes and 3D coronal views was scored according to a 7-point scale. Data analysis was performed using the Student t test and the Pearson chi-square test. RESULTS. Of the 269 patients with IUDs who had undergone ultrasound during the study period, 180 patients had a copper IUD; 59, a levonorgestrel-releasing device; and three, a Lippes loop. Twenty-seven IUDs were excluded because they were not seen on ultrasound (n = 15) or the type of IUD was not identifiable (n = 12). Of the 239 IUDs identified, the conspicuity score for copper IUDs (mean score, 5.3 [SD, 1.4]) differed significantly from that for levonorgestrel-releasing IUDs (mean, 3.1 [1.0]) on 2D ultrasound (p < 0.001). The difference in the conspicuity score for copper IUDs (mean, 6.6 [0.95]) versus that for levonorgestrel-releasing devices (mean, 6.2 [0.92]) on 3D ultrasound was marginally significant (p = 0.05). One hundred seventy-six IUDs (74%) were properly positioned within the endometrial cavity and 60 (25%) were malpositioned; proper positioning of three IUDs (1%) could not be confirmed. The indications for sonographic evaluation were pain (111/239, 46%), missing strings (91/239, 38%), and bleeding (34/239, 14%). Of the patients who presented with bleeding, the IUD was malpositioned in 13 (38%). CONCLUSION. The levonorgestrel-releasing IUD is significantly less conspicuous than the copper IUD on 2D imaging. Three-dimensional ultrasound enhances the conspicuity of both types of IUD.
引用
收藏
页码:1439 / 1443
页数:5
相关论文
共 50 条
  • [1] Learning to map 2D ultrasound images into 3D space with minimal human annotation
    Yeung, Pak-Hei
    Aliasi, Moska
    Papageorghiou, Aris T.
    Haak, Monique
    Xie, Weidi
    Namburete, Ana I. L.
    MEDICAL IMAGE ANALYSIS, 2021, 70
  • [2] Early 2D/3D ultrasound diagnosis of pleural effusion in fetuses with Turner syndrome
    Kosinski, Przemyslaw
    Ismail, Mahmoud
    Abramowicz, Jacques S.
    JOURNAL OF CLINICAL ULTRASOUND, 2018, 46 (09) : 585 - 587
  • [3] Prospective Trial of Breast MRI Versus 2D and 3D Ultrasound for Evaluation of Response to Neoadjuvant Chemotherapy
    Lee, Marie Catherine
    Gonzalez, Segundo Jaime
    Lin, Huiyi
    Zhao, Xiuhua
    Kiluk, John V.
    Laronga, Christine
    Mooney, Blaise
    ANNALS OF SURGICAL ONCOLOGY, 2015, 22 (09) : 2888 - 2894
  • [4] Women's Obstetric History and Midtrimester Cervical Length Measurements by 2D/3D and Doppler Ultrasound
    Codato Marinelli, Juliana Valente
    de Amorim Filho, Antonio Gomes
    de Barros, Monica Fairbanks
    Rodrigues, Agatha Sacramento
    Vieira Francisco, Rossana Pulcineli
    Burlacchini de Carvalho, Mario Henrique
    REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRICIA, 2020, 42 (09): : 540 - 546
  • [5] LATERAL VENTRICULAR SIZE IN EXTREMELY PREMATURE INFANTS: 3D MRI CONFIRMS 2D ULTRASOUND MEASUREMENTS
    Horsch, Sandra
    Bengtsson, Johan
    Nordell, Anders
    Lagercrantz, Hugo
    Aden, Ulrika
    Blennow, Mats
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (03) : 360 - 366
  • [6] 3D printing of intrauterine device loaded with silver sulfadiazine to the treatment of fungal diseases
    Ferrari, Gustavo
    da Silva, Loise Silveira
    Batistella, Tauana
    Mannes, Sophia
    Silveira, Joao Pedro Vaz
    Piva, Caio Prange
    Kanis, Luiz Alberto
    Salmoria, Gean Vitor
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2025, 137 (1-2) : 105 - 116
  • [7] Diagnostic and clinical value of 3D gel installation sonohysterography in addition to 2D gel installation sonohysterography in the assessment of intrauterine abnormalities
    Nieuwenhuis, Lotte L.
    de Vaate, Marjolein Bij
    Hehenkamp, Wouter J. K.
    Heymans, Martijn W.
    van Baal, Marchien
    Brolmann, Hans A. M.
    Huirne, Judith A. F.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2014, 175 : 67 - 74
  • [8] The diagnostic accuracy of 3D ultrasound compared to 2D ultrasound and MRI in the assessment of deep myometrial invasion in endometrial cancer patients: A systematic review
    Ziogas, Apostolos
    Xydias, Emmanouil
    Kalantzi, Sofi
    Papageorgouli, Despoina
    Liasidi, Polyxeni-Natalia
    Lamari, Ioanna
    Daponte, Alexandros
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2022, 61 (05): : 746 - 754
  • [9] Towards automated extraction of 2D standard fetal head planes from 3D ultrasound acquisitions: A clinical evaluation and quality assessment comparison
    Skelton, E.
    Matthew, J.
    Li, Y.
    Khanal, B.
    Martinez, J. J. Cerrolaza
    Toussaint, N.
    Gupta, C.
    Knight, C.
    Kainz, B.
    Hajnal, J. V.
    Rutherford, M.
    RADIOGRAPHY, 2021, 27 (02) : 519 - 526
  • [10] Should 3D and 4D ultrasound be used in every pregnancy?
    Kurjak, Asim
    13TH WORLD CONGRESS ON CONTROVERSIES IN OBSTETRICS, GYNECOLOGY & INFERTILITY (COGI) HELD JOINTLY WITH THE GERMAN SOCIETY OF OBSTETRICS & GYNECOLOGY, 2010, : 143 - 146