On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment

被引:33
作者
Fogliata, Antonella [1 ]
Nicolini, Giorgia [1 ]
Clivio, Alessandro [1 ]
Vanetti, Eugenio [1 ]
Cozzi, Luca [1 ]
机构
[1] IOSI, Oncol Inst So Switzerland, Med Phys Unit, Bellinzona, Switzerland
来源
RADIATION ONCOLOGY | 2011年 / 6卷
关键词
Acuros; AAA; breast; inhomogeneity correction; tissue density; PHOTON DOSE CALCULATION; ANISOTROPIC ANALYTICAL ALGORITHM; BREATHING ADAPTED RADIOTHERAPY; FUNDAMENTAL CHARACTERIZATION; HETEROGENEOUS MEDIA; VALIDATION; WATER; HOLD; VERIFICATION; CONVOLUTION;
D O I
10.1186/1748-717X-6-103
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: A new algorithm for photon dose calculation, Acuros XB, has been recently introduced in the Eclipse, Varian treatment planning system, allowing, similarly to the classic Monte Carlo methods, for accurate modelling of dose deposition in media. Aim of the present study was the assessment of its behaviour in clinical cases. Methods: Datasets from ten breast patients scanned under different breathing conditions (free breathing and deep inspiration) were used to calculate dose plans using the simple two tangential field setting, with Acuros XB (in its versions 10 and 11) and the Anisotropic Analytical Algorithm (AAA) for a 6MV beam. Acuros XB calculations were performed as dose-to-medium distributions. This feature was investigated to appraise the capability of the algorithm to distinguish between different elemental compositions in the human body: lobular vs. adipose tissue in the breast, lower (deep inspiration condition) vs. higher (free breathing condition) densities in the lung. Results: The analysis of the two breast structures presenting densities compatible with muscle and with adipose tissue showed an average difference in dose calculation between Acuros XB and AAA of 1.6%, with AAA predicting higher dose than Acuros XB, for the muscle tissue (the lobular breast); while the difference for adipose tissue was negligible. From histograms of the dose difference plans between AAA and Acuros XB (version 10), the dose of the lung portion inside the tangential fields presented an average difference of 0.5% in the free breathing conditions, increasing to 1.5% for the deep inspiration cases, with AAA predicting higher doses than Acuros XB. In lung tissue significant differences are found also between Acuros XB version 10 and 11 for lower density lung. Conclusions: Acuros XB, differently from AAA, is capable to distinguish between the different elemental compositions of the body, and suggests the possibility to further improve the accuracy of the dose plans computed for actual treatment of patients.
引用
收藏
页数:11
相关论文
共 27 条
  • [21] Ulmer W., 1996, Medical Physics, V6, P68
  • [22] Ulmer W., 1995, MED PHYS, V5, P25
  • [23] Testing of the analytical anisotropic algorithm for photon dose calculation
    Van Esch, Ann
    Tillikainen, Laura
    Pyykkonen, Jukka
    Tenhunen, Mikko
    Helminen, Hannu
    Siljamaki, Sami
    Alakuijala, Jyrki
    Paiusco, Marta
    Iori, Mauro
    Huyskens, Dominique P.
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4130 - 4148
  • [24] Feasibility of a multigroup deterministic solution method for three-dimensional radiotherapy dose calculations
    Vassiliev, Oleg N.
    Wareing, Todd A.
    Davis, Ian M.
    McGhee, John
    Barnett, Douglas
    Horton, John L.
    Gifford, Kent
    Failla, Gregory
    Titt, Uwe
    Mourtada, Firas
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : 220 - 227
  • [25] Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams
    Vassiliev, Oleg N.
    Wareing, Todd A.
    McGhee, John
    Failla, Gregory
    Salehpour, Mohammad R.
    Mourtada, Firas
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03) : 581 - 598
  • [26] Discontinuous finite element SN methods on three-dimensional unstructured grids
    Wareing, TA
    McGhee, JM
    Morel, JE
    Pautz, SD
    [J]. NUCLEAR SCIENCE AND ENGINEERING, 2001, 138 (03) : 256 - 268
  • [27] Evaluation of deep inspiration breath-hold lung treatment plans with Monte Carlo dose calculation
    Yorke, ED
    Wang, L
    Rosenzweig, KE
    Mah, D
    Paoli, JB
    Chui, CS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (04): : 1058 - 1070