On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment

被引:33
作者
Fogliata, Antonella [1 ]
Nicolini, Giorgia [1 ]
Clivio, Alessandro [1 ]
Vanetti, Eugenio [1 ]
Cozzi, Luca [1 ]
机构
[1] IOSI, Oncol Inst So Switzerland, Med Phys Unit, Bellinzona, Switzerland
来源
RADIATION ONCOLOGY | 2011年 / 6卷
关键词
Acuros; AAA; breast; inhomogeneity correction; tissue density; PHOTON DOSE CALCULATION; ANISOTROPIC ANALYTICAL ALGORITHM; BREATHING ADAPTED RADIOTHERAPY; FUNDAMENTAL CHARACTERIZATION; HETEROGENEOUS MEDIA; VALIDATION; WATER; HOLD; VERIFICATION; CONVOLUTION;
D O I
10.1186/1748-717X-6-103
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: A new algorithm for photon dose calculation, Acuros XB, has been recently introduced in the Eclipse, Varian treatment planning system, allowing, similarly to the classic Monte Carlo methods, for accurate modelling of dose deposition in media. Aim of the present study was the assessment of its behaviour in clinical cases. Methods: Datasets from ten breast patients scanned under different breathing conditions (free breathing and deep inspiration) were used to calculate dose plans using the simple two tangential field setting, with Acuros XB (in its versions 10 and 11) and the Anisotropic Analytical Algorithm (AAA) for a 6MV beam. Acuros XB calculations were performed as dose-to-medium distributions. This feature was investigated to appraise the capability of the algorithm to distinguish between different elemental compositions in the human body: lobular vs. adipose tissue in the breast, lower (deep inspiration condition) vs. higher (free breathing condition) densities in the lung. Results: The analysis of the two breast structures presenting densities compatible with muscle and with adipose tissue showed an average difference in dose calculation between Acuros XB and AAA of 1.6%, with AAA predicting higher dose than Acuros XB, for the muscle tissue (the lobular breast); while the difference for adipose tissue was negligible. From histograms of the dose difference plans between AAA and Acuros XB (version 10), the dose of the lung portion inside the tangential fields presented an average difference of 0.5% in the free breathing conditions, increasing to 1.5% for the deep inspiration cases, with AAA predicting higher doses than Acuros XB. In lung tissue significant differences are found also between Acuros XB version 10 and 11 for lower density lung. Conclusions: Acuros XB, differently from AAA, is capable to distinguish between the different elemental compositions of the body, and suggests the possibility to further improve the accuracy of the dose plans computed for actual treatment of patients.
引用
收藏
页数:11
相关论文
共 27 条
  • [1] The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumour coverage
    Aarup, Lasse Rye
    Nahum, Alan E.
    Zacharatou, Christina
    Juhler-Nottrup, Trine
    Knoos, Tommy
    Nystrom, Hakan
    Specht, Lena
    Wieslander, Elinore
    Korreman, Stine S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) : 405 - 414
  • [2] Experimental verification of convolution /superposition photon dose calculations for radiotherapy treatment planning
    Aspradakis, MM
    Morrison, RH
    Richmond, ND
    Steele, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (17) : 2873 - 2893
  • [3] Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning
    Bragg, Christopher M.
    Conway, John
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 (03) : 315 - 323
  • [4] Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations
    Bush, K.
    Gagne, I. M.
    Zavgorodni, S.
    Ansbacher, W.
    Beckham, W.
    [J]. MEDICAL PHYSICS, 2011, 38 (04) : 2208 - 2221
  • [5] Clinical comparison of head and neck and prostate IMRT plans using absorbed dose to medium and absorbed dose to water
    Dogan, N.
    Siebers, J. V.
    Keall, P. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (19) : 4967 - 4980
  • [6] Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water
    Fogliata, A
    Nicolini, G
    Vanetti, E
    Clivio, A
    Cozzi, L
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06) : 1421 - 1438
  • [7] The impact of photon dose calculation algorithms on expected dose distributions in lungs under different respiratory phases
    Fogliata, Antonella
    Nicolini, Giorgia
    Vanetti, Eugenio
    Clivio, Alessandro
    Winkler, Peter
    Cozzi, Luca
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (09) : 2375 - 2390
  • [8] On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities:: comparison with Monte Carlo calculations
    Fogliata, Antonella
    Vanetti, Eugenio
    Albers, Dirk
    Brink, Carsten
    Clivio, Alessandro
    Knoos, Tommy
    Nicolini, Giorgia
    Cozzi, Luca
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (05) : 1363 - 1385
  • [9] Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Cozzi, Luca
    [J]. RADIATION ONCOLOGY, 2011, 6
  • [10] Dosimetric validation of the Acuros XB Advanced Dose Calculation algorithm: fundamental characterization in water
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Mancosu, Pietro
    Cozzi, Luca
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06) : 1879 - 1904