Simultaneous electrothermal vaporization and nebulizer sample introduction system for inductively coupled plasma mass spectrometry

被引:5
作者
Arnquist, Isaac J. [1 ]
Kreschollek, Thomas E. [1 ]
Holcombe, James A. [1 ]
机构
[1] Univ Texas Austin, Dept Chem & Biochem, Austin, TX 78712 USA
基金
美国国家科学基金会;
关键词
Electrothermal vaporization; Inductively coupled plasma mass spectrometry; ETV-ICP-MS; Nebulizer; TRACE-METALS; MIXED-GAS; ICP-MS; SIGNAL; PARTICLES; ELEMENTS; WATER; TOOL;
D O I
10.1016/j.sab.2011.02.004
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The novel analytical application of the combination of an inline electrothermal vaporization (ETV) and nebulization source for inductively coupled plasma mass spectrometry (ICP-MS) has been studied. Wet plasma conditions are sustained during ETV introduction by 200 mL/min gas flow through the nebulizer, which is merged with the ETV transport line at the torch. The use of a wet plasma with ETV introduction avoided the need to change power settings and torch positions that normally accompany a change from wet to dry plasma operating conditions. This inline-ETV source is shown to have good detection limits for a variety of elements in both HNO3 and HCl matrices. Using the inline-ETV source, improved limits of detection (LOD) were obtained for elements typically suppressed by polyatomic interferences using a nebulizer. Specifically, improved LODs for V-51 and Cr-53 suffering from Cl interferences ((ClO+)-Cl-51 and (ClO+)-Cl-53 respectively) in a 1% HCl matrix were obtained using the inline-ETV source. LODs were improved by factors of 65 and 22 for V-51 and Cr-53, respectively, using the inline-ETV source compared to a conventional concentric glass nebulizer. For elements without polyatomic interferences, LODs from the inline-ETV were comparable to conventional dry plasma ETV-ICP time-of-flight mass spectrometry results. Lastly, the inline-ETV source offers a simple means of changing from nebulizer introduction to inline-ETV introduction without extinguishing the plasma. This permits, for example, the use of the time-resolved ETV-ICP-MS signals to distinguish between an analyte ion and polyatomic isobar. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:255 / 260
页数:6
相关论文
共 25 条
[1]   SIGNAL ENHANCEMENT OF ELEMENTS DUE TO THE PRESENCE OF CARBON-CONTAINING COMPOUNDS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
JAUNAULT, L ;
MAURAS, Y ;
MERMET, JM ;
DELAPORTE, T .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1497-1498
[2]   Isotope ratio determination by laser ablation-single collector-inductively coupled plasma-mass spectrometry. General capabilities and possibilities for improvement [J].
Aramendia, Maite ;
Resano, Martin ;
Vanhaecke, Frank .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (03) :390-404
[3]   Electrothermal vaporization-inductively coupled plasma-mass spectrometry: A versatile tool for tackling challenging samples A critical review [J].
Aramendia, Maite ;
Resano, Martin ;
Vanhaecke, Frank .
ANALYTICA CHIMICA ACTA, 2009, 648 (01) :23-44
[4]   The use of concomitant elements to evaluate an Ar-N2 mixed-gas plasma by electrothermal vaporization inductively coupled plasma orthogonal time-of-flight mass spectrometry [J].
Balsanek, William J. ;
Ertas, Gulay ;
Holcombe, James A. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (06) :732-742
[5]  
BALSANEK WJ, 2005, THESIS U TEXAS AUSTI, P141
[6]  
Byrne JP, 1998, ATOM SPECTROSC, V19, P116
[7]   EVALUATION OF A MODIFIED COMMERCIAL GRAPHITE-FURNACE FOR REDUCTION OF ISOBARIC INTERFERENCES IN ARGON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
CAREY, JM ;
EVANS, EH ;
CARUSO, JA ;
SHEN, WL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (13) :1711-1721
[8]   Direct determination of trace metals in sea-water using electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Chapple, G ;
Byrne, JP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (08) :549-553
[9]   ALTERNATIVES TO ALL-ARGON PLASMAS IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) - AN OVERVIEW [J].
DURRANT, SF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (10-11) :389-392
[10]   Optimization of ETV-ICP(TOF)MS and transient signal profiles for reducing isobaric interferences [J].
Ertas, G ;
Holcombe, JA .