Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording

被引:64
作者
Deku, Felix [1 ]
Cohen, Yarden [2 ,3 ]
Joshi-Imre, Alexandra [1 ]
Kanneganti, Aswini [1 ]
Gardner, Timothy J. [2 ,3 ]
Cogan, Stuart F. [1 ]
机构
[1] Univ Texas Dallas, Dept Bioengn, 800 W Campbell Rd, Richardson, TX 75080 USA
[2] Boston Univ, Dept Biol, Boston, MA 02215 USA
[3] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
关键词
amorphous silicon carbide; ultramicroelectrode; neural stimulation; neural recording; low impedance coating; CHARGE-INJECTION LIMITS; CURRENT-DENSITY PROFILES; IRIDIUM OXIDE AIROF; MICROELECTRODE ARRAYS; CEREBRAL-CORTEX; BRAIN-TISSUE; THIN-FILMS; ELECTRODE ARRAY; ENCAPSULATION; DESIGN;
D O I
10.1088/1741-2552/aa8f8b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Foreign body response to indwelling cortical microelectrodes limits the reliability of neural stimulation and recording, particularly for extended chronic applications in behaving animals. The extent to which this response compromises the chronic stability of neural devices depends on many factors including the materials used in the electrode construction, the size, and geometry of the indwelling structure. Here, we report on the development of microelectrode arrays (MEAs) based on amorphous silicon carbide (a-SiC). Approach. This technology utilizes a-SiC for its chronic stability and employs semiconductor manufacturing processes to create MEAs with small shank dimensions. The a-SiC films were deposited by plasma enhanced chemical vapor deposition and patterned by thin-film photolithographic techniques. To improve stimulation and recording capabilities with small contact areas, we investigated low impedance coatings on the electrode sites. The assembled devices were characterized in phosphate buffered saline for their electrochemical properties. Main results. MEAs utilizing a-SiC as both the primary structural element and encapsulation were fabricated successfully. These a-SiC MEAs had 16 penetrating shanks. Each shank has a cross-sectional area less than 60 mu m(2) and electrode sites with a geometric surface area varying from 20 to 200 mu m(2). Electrode coatings of TiN and SIROF reduced 1 kHz electrode impedance to less than 100 k Omega from similar to 2.8 M Omega for 100 mu m(2) Au electrode sites and increased the charge injection capacities to values greater than 3 mC cm(-2). Finally, we demonstrated functionality by recording neural activity from basal ganglia nucleus of Zebra Finches and motor cortex of rat. Significance. The a-SiC MEAs provide a significant advancement in the development of microelectrodes that over the years has relied on silicon platforms for device manufacture. These flexible a-SiC MEAs have the potential for decreased tissue damage and reduced foreign body response. The technique is promising and has potential for clinical translation and large scale manufacturing.
引用
收藏
页数:12
相关论文
共 78 条
[61]   Low-stress PECVD SiC thin films for IC-compatible microstructures [J].
Sarro, PM ;
deBoer, CR ;
Korkmaz, E ;
Laros, JMW .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 67 (1-3) :175-180
[62]   Neural probe design for reduced tissue encapsulation in CNS [J].
Seymour, John P. ;
Kipke, Daryl R. .
BIOMATERIALS, 2007, 28 (25) :3594-3607
[63]   Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays [J].
Skousen, John L. ;
Merriam, Mary Elizabeth ;
Srivannavit, Onnap ;
Perlin, Gaytri ;
Wise, Kensall D. ;
Tresco, Patrick A. .
BRAIN MACHINE INTERFACES: IMPLICATIONS FOR SCIENCE, CLINICAL PRACTICE AND SOCIETY, 2011, 194 :167-180
[64]   Thin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortex [J].
Stice, Paula ;
Gilletti, Aaron ;
Panitch, Alyssa ;
Muthuswamy, Jit .
JOURNAL OF NEURAL ENGINEERING, 2007, 4 (02) :42-53
[66]   INVITRO MEASUREMENT AND CHARACTERIZATION OF CURRENT-DENSITY PROFILES PRODUCED BY NONRECESSED, SIMPLE RECESSED, AND RADIALLY VARYING RECESSED STIMULATING ELECTRODES [J].
SUESSERMAN, MF ;
SPELMAN, FA ;
RUBINSTEIN, JT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (05) :401-408
[67]   Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex [J].
Suner, S ;
Fellows, MR ;
Vargas-Irwin, C ;
Nakata, GK ;
Donoghue, JP .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (04) :524-541
[68]   Brain responses to micro-machined silicon devices [J].
Szarowski, DH ;
Andersen, MD ;
Retterer, S ;
Spence, AJ ;
Isaacson, M ;
Craighead, HG ;
Turner, JN ;
Shain, W .
BRAIN RESEARCH, 2003, 983 (1-2) :23-35
[69]  
Troyk PR, 2004, P ANN INT IEEE EMBS, V26, P4141
[70]   Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex [J].
Vetter, RJ ;
Williams, JC ;
Hetke, JF ;
Nunamaker, EA ;
Kipke, DR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (06) :896-904