Comparison of styrene-divinylbenzene-based monoliths and Vydac nano-liquid chromatography columns for protein analysis

被引:32
作者
Legido-Quigley, C
Marlin, N
Smith, NW
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem, Ctr Analyt Sci, London SW7 2AY, England
[2] Kings Coll London, Dept Pharm, Microseparat Grp, London SE1 9NN, England
关键词
monolithic columns; stationary phases; LC; poly(styrene-divinylbenzene); proteins;
D O I
10.1016/j.chroma.2004.01.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This report details the fabrication of polystyrene-based nano-LC monolithic columns for the separation of protein molecules. The report focuses on the practical advantages of monolithic columns when compared to conventional packed columns. Capillary columns were made to 100 and 50 mum W. and used to analyse a mixture of proteins, these separations were then compared with a conventional protein phase under the same conditions. A second functionalised monolithic polystyrene-based column was also manufactured and compared for the analysis of proteins, under the same analytical conditions, to the standard non-functionalised bare polystyrene monolith. Nano-LC polystyrene monolithic columns were found to be advantageous to conventional phases for the analysis of protein molecules, with a one-step fabrication process, faster analysis times, lower limits of detection hence higher sensitivity. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 11 条
[1]  
Braithwaite A., 1996, CHROMATOGRAPHIC METH
[2]   Methacrylate monolithic columns of 320 μm ID for capillary liquid chromatography [J].
Coufal, P ;
Cihák, M ;
Suchánková, J ;
Tesarová, E ;
Bosáková, Z ;
Stulík, K .
JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) :99-106
[3]  
Deyl Z., 2003, MONOLITHIC MAT PREPA, P67
[4]   Polymeric monolithic stationary phases for capillary electrochromatography [J].
Hilder, EF ;
Svec, F ;
Fréchet, JMJ .
ELECTROPHORESIS, 2002, 23 (22-23) :3934-3953
[5]   Advances in capillary electrochromatography and micro-high performance liquid chromatography monolithic columns for separation science [J].
Legido-Quigley, C ;
Marlin, ND ;
Melin, V ;
Manz, A ;
Smith, NW .
ELECTROPHORESIS, 2003, 24 (06) :917-944
[6]   Quantification of the sensitivity increase of a micro-high-performance liquid chromatography-electrospray ionization mass spectrometry system with decreasing column diameter [J].
Legido-Quigley, C ;
Smith, NW ;
Mallet, D .
JOURNAL OF CHROMATOGRAPHY A, 2002, 976 (1-2) :11-18
[7]   Capillary monoliths for the analysis of nucleic acids by high-performance liquid chromatography-electrospray ionization mass spectrometry [J].
Oberacher, H ;
Huber, CG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (03) :166-174
[8]   A decade of high-resolution liquid chromatography of nucleic acids on styrene-divinylbenzene copolymers [J].
Oefner, PJ ;
Huber, CG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 782 (1-2) :27-55
[9]   High-performance liquid chromatography-electrospray ionization mass spectrometry of single- and double-stranded nucleic acids using monolithic capillary columns [J].
Premstaller, A ;
Oberacher, H ;
Huber, CG .
ANALYTICAL CHEMISTRY, 2000, 72 (18) :4386-4393
[10]   High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies [J].
Premstaller, A ;
Oberacher, H ;
Walcher, W ;
Timperio, AM ;
Zolla, L ;
Chervet, JP ;
Cavusoglu, N ;
van Dorsselaer, A ;
Huber, CG .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2390-+