Symbitron Exoskeleton: Design, Control, and Evaluation of a Modular Exoskeleton for Incomplete and Complete Spinal Cord Injured Individuals

被引:57
|
作者
Meijneke, C. [1 ]
van Oort, G. [2 ]
Sluiter, V [2 ]
van Asseldonk, E. [2 ]
Tagliamonte, N. L. [3 ]
Tamburella, F. [3 ]
Pisotta, I [3 ]
Masciullo, M. [3 ]
Arquilla, M. [3 ]
Molinari, M. [3 ]
Wu, A. R. [4 ]
Dzeladini, F. [4 ]
Ijspeert, A. J. [4 ]
van der Kooij, H. [2 ,5 ]
机构
[1] Delft Univ Technol, Elect & Mech Support Div, NL-2628 CD Delft, Netherlands
[2] Univ Twente, Dept Biomech Engn, NL-7522 NB Enschede, Netherlands
[3] Fdn Santa Lucia, NeuroRobot Lab, I-00179 Rome, Italy
[4] Ecole Polytech Fed Lausanne, Biorobot BIOROB Lab, CH-1015 Lausanne, Switzerland
[5] Delft Univ Technol, Dept Biomech Engn, NL-2628 CD Delft, Netherlands
关键词
Exoskeletons; Legged locomotion; Actuators; Hip; Lesions; Knee; Springs; Exoskeleton; modular; orthosis; SCI; series elastic actuation (SEA); neuromuscular control (NMC);
D O I
10.1109/TNSRE.2021.3049960
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we present the design, control, and preliminary evaluation of the Symbitron exoskeleton, a lower limb modular exoskeleton developed for people with a spinal cord injury. The mechanical and electrical configuration and the controller can be personalized to accommodate differences in impairments among individuals with spinal cord injuries (SCI). In hardware, this personalization is accomplished by a modular approach that allows the reconfiguration of a lower-limb exoskeleton with ultimately eight powered series actuated (SEA) joints and high fidelity torque control. For SCI individuals with an incomplete lesion and sufficient hip control, we applied a trajectory-free neuromuscular control (NMC) strategy and used the exoskeleton in the ankle-knee configuration. For complete SCI individuals, we used a combination of a NMC and an impedance based trajectory tracking strategy with the exoskeleton in the ankle-knee-hip configuration. Results of a preliminary evaluation of the developed hardware and software showed that SCI individuals with an incomplete lesion could naturally vary their walking speed and step length and walked faster compared to walking without the device. SCI individuals with a complete lesion, who could not walk without support, were able to walk with the device and with the support of crutches that included a push-button for step initiation Our results demonstrate that an exoskeleton with modular hardware and control allows SCI individuals with limited or no lower limb function to receive tailored support and regain mobility.
引用
收藏
页码:330 / 339
页数:10
相关论文
共 48 条
  • [21] Exoskeleton-assisted gait training to improve gait in individuals with spinal cord injury: A pilot randomized study
    Chang S.-H.
    Afzal T.
    Berliner J.
    Francisco G.E.
    Pilot and Feasibility Studies, 4 (1)
  • [22] Feasibility, safety, and functional outcomes using the neurological controlled Hybrid Assistive Limb exoskeleton (HAL®) following acute incomplete and complete spinal cord injury - Results of 50 patients
    Aach, Mirko
    Schildhauer, Thomas Armin
    Zieriacks, Amrei
    Jansen, Oliver
    Wessling, Martin
    Brinkemper, Alexis
    Grasmuecke, Dennis
    JOURNAL OF SPINAL CORD MEDICINE, 2023, 46 (04) : 574 - 581
  • [23] Mechanical Design of RiceWrist-S: a Forearm-Wrist Exoskeleton for Stroke and Spinal Cord Injury Rehabilitation
    Pehlivan, Ali Utku
    Lee, Sangyoon
    O'Malley, Marcia K.
    2012 4TH IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2012, : 1573 - 1578
  • [24] Knowledge Gaps in Biophysical Changes After Powered Robotic Exoskeleton Walking by Individuals With Spinal Cord Injury-A Scoping Review
    Yip, Christopher C. H.
    Lam, Chor-Yin
    Cheung, Kenneth M. C.
    Wong, Yat Wa
    Koljonen, Paul A.
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [25] Opinions on the Preclinical Evaluation of Novel Therapies for Spinal Cord Injury: A Comparison between Researchers and Spinal Cord-Injured Individuals
    Kwon, Brian K.
    Ghag, Arvindera
    Reichl, Leilani
    Dvorak, Marcel F.
    Illes, Judy
    Tetzlaff, Wolfram
    JOURNAL OF NEUROTRAUMA, 2012, 29 (14) : 2367 - 2374
  • [26] Biomechanical and electromyographic assessment of spastic hypertonus in motor complete traumatic spinal cord-injured individuals
    Grippo, A.
    Carrai, R.
    Hawamdeh, Z.
    Falsini, C.
    Aito, S.
    Pinto, F.
    de Scisciolo, G.
    Pizzi, A.
    SPINAL CORD, 2011, 49 (01) : 142 - 148
  • [27] Biomechanical and electromyographic assessment of spastic hypertonus in motor complete traumatic spinal cord-injured individuals
    A Grippo
    R Carrai
    Z Hawamdeh
    C Falsini
    S Aito
    F Pinto
    G de Scisciolo
    A Pizzi
    Spinal Cord, 2011, 49 : 142 - 148
  • [28] Weight Bearing Over-ground Stepping in an Exoskeleton with Non-invasive Spinal Cord Neuromodulation after Motor Complete Paraplegia
    Gad, Parag
    Gerasimenko, Yury
    Zdunowski, Sharon
    Tumer, Amanda
    Sayenko, Dimitry
    Lu, Daniel C.
    Reggie Edgerton, V.
    FRONTIERS IN NEUROSCIENCE, 2017, 11
  • [29] Movement-provoked muscle torque and EMG activity in longstanding motor complete spinal cord injured individuals
    Sköld, C
    Harms-Ringdahl, K
    Seiger, Å
    JOURNAL OF REHABILITATION MEDICINE, 2002, 34 (02) : 86 - 90
  • [30] Cardiopulmonary function after robotic exoskeleton-assisted over-ground walking training of a patient with an incomplete spinal cord injury Case report
    Jang, Yun-Chol
    Park, Hyeng-Kyu
    Han, Jae-Young
    Choi, In Sung
    Song, Min-Keun
    MEDICINE, 2019, 98 (50)