Symbitron Exoskeleton: Design, Control, and Evaluation of a Modular Exoskeleton for Incomplete and Complete Spinal Cord Injured Individuals

被引:57
|
作者
Meijneke, C. [1 ]
van Oort, G. [2 ]
Sluiter, V [2 ]
van Asseldonk, E. [2 ]
Tagliamonte, N. L. [3 ]
Tamburella, F. [3 ]
Pisotta, I [3 ]
Masciullo, M. [3 ]
Arquilla, M. [3 ]
Molinari, M. [3 ]
Wu, A. R. [4 ]
Dzeladini, F. [4 ]
Ijspeert, A. J. [4 ]
van der Kooij, H. [2 ,5 ]
机构
[1] Delft Univ Technol, Elect & Mech Support Div, NL-2628 CD Delft, Netherlands
[2] Univ Twente, Dept Biomech Engn, NL-7522 NB Enschede, Netherlands
[3] Fdn Santa Lucia, NeuroRobot Lab, I-00179 Rome, Italy
[4] Ecole Polytech Fed Lausanne, Biorobot BIOROB Lab, CH-1015 Lausanne, Switzerland
[5] Delft Univ Technol, Dept Biomech Engn, NL-2628 CD Delft, Netherlands
关键词
Exoskeletons; Legged locomotion; Actuators; Hip; Lesions; Knee; Springs; Exoskeleton; modular; orthosis; SCI; series elastic actuation (SEA); neuromuscular control (NMC);
D O I
10.1109/TNSRE.2021.3049960
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we present the design, control, and preliminary evaluation of the Symbitron exoskeleton, a lower limb modular exoskeleton developed for people with a spinal cord injury. The mechanical and electrical configuration and the controller can be personalized to accommodate differences in impairments among individuals with spinal cord injuries (SCI). In hardware, this personalization is accomplished by a modular approach that allows the reconfiguration of a lower-limb exoskeleton with ultimately eight powered series actuated (SEA) joints and high fidelity torque control. For SCI individuals with an incomplete lesion and sufficient hip control, we applied a trajectory-free neuromuscular control (NMC) strategy and used the exoskeleton in the ankle-knee configuration. For complete SCI individuals, we used a combination of a NMC and an impedance based trajectory tracking strategy with the exoskeleton in the ankle-knee-hip configuration. Results of a preliminary evaluation of the developed hardware and software showed that SCI individuals with an incomplete lesion could naturally vary their walking speed and step length and walked faster compared to walking without the device. SCI individuals with a complete lesion, who could not walk without support, were able to walk with the device and with the support of crutches that included a push-button for step initiation Our results demonstrate that an exoskeleton with modular hardware and control allows SCI individuals with limited or no lower limb function to receive tailored support and regain mobility.
引用
收藏
页码:330 / 339
页数:10
相关论文
共 48 条
  • [1] Predictors of exoskeleton motor learning in spinal cord injured patients
    van Dijsseldonk, Rosanne B.
    Rijken, Hennie
    van Nes, Ilse J. W.
    van de Meent, Henk
    Keijsers, Noel L. W.
    DISABILITY AND REHABILITATION, 2021, 43 (14) : 1982 - 1988
  • [2] Design, Control, and Pilot Study of a Lightweight and Modular Robotic Exoskeleton for Walking Assistance After Spinal Cord Injury
    Font-Llagunes, Josep M.
    Lugris, Urbano
    Clos, Daniel
    Alonso, F. Javier
    Cuadrado, Javier
    JOURNAL OF MECHANISMS AND ROBOTICS-TRANSACTIONS OF THE ASME, 2020, 12 (03):
  • [3] Volition-adaptive control for gait training using wearable exoskeleton: preliminary tests with incomplete spinal cord injury individuals
    Vijaykumar Rajasekaran
    Eduardo López-Larraz
    Fernando Trincado-Alonso
    Joan Aranda
    Luis Montesano
    Antonio J. del-Ama
    Jose L. Pons
    Journal of NeuroEngineering and Rehabilitation, 15
  • [4] Volition-adaptive control for gait training using wearable exoskeleton: preliminary tests with incomplete spinal cord injury individuals
    Rajasekaran, Vijaykumar
    Lopez-Larraz, Eduardo
    Trincado-Alonso, Fernando
    Aranda, Joan
    Montesano, Luis
    del-Ama, Antonio J.
    Pons, Jose L.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2018, 15
  • [5] Design and Torque Control of a Modular Reconfigurable Variable Stiffness Exoskeleton for Improved Transparency
    Zhu, Yanghui
    Wu, Qingcong
    Chen, Bai
    Tang, Qirong
    Zeng, Hong
    Wu, Hongtao
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2025,
  • [6] Design and validation of the RiceWrist-S exoskeleton for robotic rehabilitation after incomplete spinal cord injury
    Pehlivan, Ali Utku
    Sergi, Fabrizio
    Erwin, Andrew
    Yozbatiran, Nuray
    Francisco, Gerard E.
    O'Malley, Marcia K.
    ROBOTICA, 2014, 32 (08) : 1415 - 1431
  • [7] Exoskeleton for Gait Training in Spinal Cord Injured People: Clinical Analysis and Ethical Dilemmas
    Bissolotti, Luciano
    Zuccher, Paola
    Zenorini, Andrea
    Chiari, Sonia
    Gaffurini, Paolo
    Pasini, Armando
    Nicoli, Federico
    ADVANCES IN SERVICE AND INDUSTRIAL ROBOTICS, 2018, 49 : 759 - 765
  • [8] A Framework for Measuring the Progress in Exoskeleton Skills in People with Complete Spinal Cord Injury
    van Dijsseldonk, Rosanne B.
    Rijken, Hennie
    van Nes, Ilse J. W.
    van de Meent, Henk
    Keijsers, Noel L. W.
    FRONTIERS IN NEUROSCIENCE, 2017, 11
  • [9] A Robotic Exoskeleton for Rehabilitation and Assessment of the Upper Limb Following Incomplete Spinal Cord Injury
    Fitle, Kyle D.
    Pehlivan, Ali Utku
    O'Malley, Marcia K.
    2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2015, : 4960 - 4966
  • [10] Neuromuscular Controller Embedded in a Powered Ankle Exoskeleton: Effects on Gait, Clinical Features and Subjective Perspective of Incomplete Spinal Cord Injured Subjects
    Tamburella, F.
    Tagliamonte, N. L.
    Pisotta, I
    Masciullo, M.
    Arquilla, M.
    van Asseldonk, E. H. F.
    van Der Kooij, H.
    Wu, A. R.
    Dzeladini, F.
    Ijspeert, A. J.
    Molinari, M.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (05) : 1157 - 1167