Development of patient-specific 3D models from histopathological samples for applications in radiation therapy

被引:5
|
作者
DeCunha, Joseph M. [1 ]
Poole, Christopher M. [2 ]
Vallieres, Martin [3 ]
Torres, Jose [4 ]
Camilleri-Broet, Sophie [4 ]
Rayes, Roni F. [5 ]
Spicer, Jonathan D. [5 ]
Enger, Shirin A. [1 ,6 ,7 ]
机构
[1] McGill Univ, Fac Med, Dept Oncol, Med Phys Unit, Montreal, PQ, Canada
[2] Radiat Analyt Pty Ltd, Sunshine Coast, Australia
[3] Univ Sherbrooke, Dept Comp Sci, Sherbrooke, PQ, Canada
[4] McGill Univ, Fac Med, Dept Pathol, Montreal, PQ, Canada
[5] McGill Univ, Canc Res Program, Dept Surg, Div Upper GI & Thorac Surg,Res Inst,Hlth Ctr, Montreal, PQ, Canada
[6] McGill Univ, Res Inst, Hlth Ctr, Montreal, PQ, Canada
[7] Jewish Gen Hosp, Lady Davis Inst Med Res, Montreal, PQ, Canada
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2021年 / 81卷
关键词
Histopathology; Cellular dosimetry; Patient-specific; Microdosimetry; VOLUME FRACTION;
D O I
10.1016/j.ejmp.2020.12.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The biological effects of ionizing radiation depend on the tissue, tumor type, radiation quality, and patient-specific factors. Inter-patient variation in cell/nucleus size may influence patient-specific dose response. However, this variability in dose response is not well investigated due to lack of available cell/nucleus size data. The aim of this study was to develop methods to derive cell/nucleus size distributions from digital images of 2D histopathological samples and use them to build digital 3D models for use in cellular dosimetry. Nineteen of sixty hematoxylin and eosin stained lung adenocarcinoma samples investigated passed exclusion criterion to be analyzed in the study. A difference of gaussians blob detection algorithm was used to identify nucleus centers and quantify cell spacing. Hematoxylin content was measured to determine nucleus radius. Pouring simulations were conducted to generate one-hundred 3D models containing volumes of equivalent cell spacing and nuclei radius to those in histopathological samples. The nuclei radius distributions of non-tumoral and cancerous regions appearing in the same slide were significantly different (p < 0.01) in all samples analyzed. The median nuclear-cytoplasmic ratio was 0.36 for non-tumoral cells and 0.50 for cancerous cells. The average cellular and nucleus packing densities in the 3D models generated were 65.9% (SD: 1.5%) and 13.3% (SD: 0.3%) respectively. Software to determine cell spacing and nuclei radius from histopathological samples was developed. 3D digital tissue models containing volumes with equivalent cell spacing, nucleus radius, and packing density to cancerous tissues were generated.
引用
收藏
页码:162 / 169
页数:8
相关论文
共 50 条
  • [31] Personalized Human Factor and Ergonomics: Usability Design of 3D Printed Patient-Specific Fracture External Fixator
    Li, Hongwei
    Qiao, Feng
    Li, Dichen
    Liang, Jixiang
    ADVANCES IN ADDITIVE MANUFACTURING, MODELING SYSTEMS AND 3D PROTOTYPING, 2020, 975 : 119 - 128
  • [32] Patient-specific 3D-printed Splint for Mallet Finger Injury
    Zolfagharian, Ali
    Gregory, Timothy M.
    Bodaghi, Mahdi
    Gharaie, Saleh
    Fay, Pearse
    INTERNATIONAL JOURNAL OF BIOPRINTING, 2020, 6 (02) : 16 - 28
  • [33] A 3-D-PRINTED PATIENT-SPECIFIC ULTRASOUND PHANTOM FOR FAST SCAN
    Al-Zogbi, Lidia
    Bock, Brian
    Schaffer, Saul
    Fleiter, Thorsten
    Krieger, Axel
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (03) : 820 - 832
  • [34] 3D-printed Patient-specific Spine Implants A Systematic Review
    Wallace, Nicholas
    Schaffer, Nathaniel E.
    Aleem, Ilyas S.
    Patel, Rakesh
    CLINICAL SPINE SURGERY, 2020, 33 (10): : 400 - 407
  • [35] Augmented patient-specific facial prosthesis production using medical imaging modelling and 3D printing technologies for improved patient outcomes
    Mohammed, Mazher I.
    Cadd, Brenton
    Peart, Greg
    Gibson, Ian
    VIRTUAL AND PHYSICAL PROTOTYPING, 2018, 13 (03) : 164 - 176
  • [36] Accuracy of intertrochanteric osteotomy for patients with slipped capital femoral epiphysis operated with 3D printed patient-specific guides
    van den Boorn, M.
    Dobbe, J. G. G.
    Lagerburg, V.
    Witbreuk, M. M. E. H.
    Streekstra, G. J.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [37] Patient-specific cylinder templates for hybrid interstitial vaginal brachytherapy: Feasibility of automated 3-D design, 3D printing, and dosimetric outlook
    Kudla, Michael
    Bachand, Francois
    Moore, Jocelyn
    Batchelar, Deidre
    BRACHYTHERAPY, 2023, 22 (04) : 468 - 476
  • [38] A model-based 3D patient-specific pre-treatment QA method for VMAT using the EPID
    McCowan, P. M.
    Asuni, G.
    van Beek, T.
    van Uytven, E.
    Kujanpaa, K.
    McCurdy, B. M. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04) : 1600 - 1612
  • [39] Toward Patient-Specific 3D-Printed Robotic Systems for Surgical Interventions
    Desai, Jaydev P.
    Sheng, Jun
    Cheng, Shing Shin
    Wang, Xuefeng
    Deaton, Nancy J.
    Rahman, Nahian
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2019, 1 (02): : 77 - 87
  • [40] An investigation into patient-specific 3D printed titanium stents and the use of etching to overcome Selective Laser Melting design constraints
    McGee, Orla M.
    Geraghty, Sam
    Hughes, Celia
    Jamshidi, Parastoo
    Kenny, Damien P.
    Attallah, Moataz M.
    Lally, Caitriona
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 134