A Multi-center Prospective Study for Implementation of an MRI-Only Prostate Treatment Planning Workflow

被引:25
作者
Greer, Peter [1 ,2 ]
Martin, Jarad [1 ,2 ]
Sidhom, Mark [3 ,4 ]
Hunter, Perry [1 ]
Pichler, Peter [1 ]
Choi, Jae Hyuk [2 ]
Best, Leah [5 ]
Smart, Joanne [1 ]
Young, Tony [3 ,6 ]
Jameson, Michael [3 ,4 ,7 ,8 ]
Afinidad, Tess [3 ]
Wratten, Chris [1 ,2 ]
Denham, James [1 ,2 ]
Holloway, Lois [3 ,4 ,7 ]
Sridharan, Swetha [1 ]
Rai, Robba [3 ,4 ,7 ]
Liney, Gary [3 ,4 ,7 ]
Raniga, Parnesh [9 ]
Dowling, Jason [2 ,4 ,9 ]
机构
[1] Calvary Mater Newcastle, Dept Radiat Oncol, Newcastle, NSW, Australia
[2] Univ Newcastle, Sch Math & Phys Sci, Newcastle, NSW, Australia
[3] Liverpool Hosp Canc Therapy Ctr, Sydney, NSW, Australia
[4] Univ New South Wales, South Western Sydney Clin Sch, Sydney, NSW, Australia
[5] HNE Hlth Serv, Hunter New England Imaging, Newcastle, NSW, Australia
[6] Univ Sydney, Sch Phys, Sydney, NSW, Australia
[7] Ingham Inst Appl Med Res, Sydney, NSW, Australia
[8] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[9] CSIRO, Australian E Hlth Res Ctr, Brisbane, Qld, Australia
来源
FRONTIERS IN ONCOLOGY | 2019年 / 9卷
基金
英国医学研究理事会;
关键词
MRI-only; synthetic CT; pseudo-CT; MRI-alone; prostate; COMPUTED-TOMOGRAPHY GENERATION; RADIATION-THERAPY; FIDUCIAL MARKERS; RESONANCE; CT; IMAGES;
D O I
10.3389/fonc.2019.00826
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This project investigates the feasibility of implementation of MRI-only prostate planning in a prospective multi-center study. Method and Materials: A two-phase implementation model was utilized where centers performed retrospective analysis of MRI-only plans for five patients followed by prospective MRI-only planning for subsequent patients. Feasibility was assessed if at least 23/25 patients recruited to phase 2 received MRI-only treatment workflow. Whole-pelvic MRI scans (T2 weighted, isotropic 1.6 mm voxel 3D sequence) were converted to pseudo-CT using an established atlas-based method. Dose plans were generated using MRI contoured anatomy with pseudo-CT for dose calculation. A conventional CT scan was acquired subsequent to MRI-only plan approval for quality assurance purposes (QA-CT). 3D Gamma evaluation was performed between pseudo-CT calculated plan dose and recalculation on QA-CT. Criteria was 2%, 2 mm criteria with 20% low dose threshold. Gold fiducial marker positions for image guidance were compared between pseudo-CT and QA-CT scan prior to treatment. Results: All 25 patients recruited to phase 2 were treated using the MRI-only workflow. Isocenter dose differences between pseudo-CT and QA-CT were -0.04 +/- 0.93% (mean +/- SD). 3D Gamma dose comparison pass-rates were 99.7% +/- 0.5% with mean gamma 0.22 +/- 0.07. Results were similar for the two centers using two different scanners. All gamma comparisons exceeded the 90% pass-rate tolerance with a minimum gamma pass-rate of 98.0%. In all cases the gold fiducial markers were correctly identified on MRI and the distances of all seeds to centroid were within the tolerance of 1.0 mm of the distances on QA-CT (0.07 +/- 0.41 mm), with a root-mean-square difference of 0.42 mm. Conclusion: The results support the hypothesis that an MRI-only prostate workflow can be implemented safely and accurately with appropriate quality assurance methods.
引用
收藏
页数:9
相关论文
共 25 条
  • [1] Dosimetric evaluation of MRI-based treatment planning for prostate cancer
    Chen, L
    Price, RA
    Nguyen, TB
    Wang, L
    Li, JS
    Qin, L
    Ding, M
    Palacio, E
    Ma, CM
    Pollack, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (22) : 5157 - 5170
  • [2] The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer
    Debois, M
    Oyen, R
    Maes, F
    Verswijvel, G
    Gatti, G
    Bosmans, H
    Feron, M
    Bellon, E
    Kutcher, G
    Van Poppel, H
    Vanuytsel, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (04): : 857 - 865
  • [3] Dowling J, 2010, LECT NOTES COMPUT SC, V6367, P25, DOI 10.1007/978-3-642-15989-3_4
  • [4] Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences
    Dowling, Jason A.
    Sun, Jidi
    Pichler, Peter
    Rivest-Henault, David
    Ghose, Soumya
    Richardson, Haylea
    Wratten, Chris
    Martin, Jarad
    Arm, Jameen
    Best, Leah
    Chandra, Shekhar S.
    Fripp, Jurgen
    Menk, Frederick W.
    Greer, Peter B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (05): : 1144 - 1153
  • [5] A review of substitute CT generation for MRI-only radiation therapy
    Edmund, Jens M.
    Nyholm, Tufve
    [J]. RADIATION ONCOLOGY, 2017, 12
  • [6] Fernandes CD, 2017, PHYS IMAG RADIAT ONC, V1, P14, DOI 10.1016/j.phro.2017.02.001
  • [7] MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection
    Ghose, Soumya
    Mitra, Jhimli
    Rivest-Henault, David
    Fazlollahi, Amir
    Stanwell, Peter
    Pichler, Peter
    Sun, Jidi
    Fripp, Jurgen
    Greer, Peter B.
    Dowling, Jason A.
    [J]. MEDICAL PHYSICS, 2016, 43 (05) : 2218 - 2228
  • [8] Greer PB, 2011, MED J AUSTRALIA, V194, pS24
  • [9] Registration free automatic identification of gold fiducial markers in MRI target delineation images for prostate radiotherapy
    Gustafsson, Christian
    Korhonen, Juha
    Persson, Emilia
    Gunnlaugsson, Adalsteinn
    Nyholm, Tufve
    Olsson, Lars E.
    [J]. MEDICAL PHYSICS, 2017, 44 (11) : 5563 - 5574
  • [10] Systematic Review of Synthetic Computed Tomography Generation Methodologies for Use in Magnetic Resonance Imaging-Only Radiation Therapy
    Johnstone, Emily
    Wyatt, Jonathan J.
    Henry, Ann M.
    Short, Susan C.
    Sebag-Montefiore, David
    Murray, Louise
    Kelly, Charles G.
    McCallum, Hazel M.
    Speight, Richard
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (01): : 199 - 217