Radio-Frequency Biosensors for Real-Time and Continuous Glucose Detection

被引:33
作者
Jang, Chorom [1 ]
Lee, Hee-Jo [2 ]
Yook, Jong-Gwan [1 ]
机构
[1] Yonsei Univ, Dept Elect & Elect Engn, Seoul 03722, South Korea
[2] Daegu Univ, Dept Phys Educ, Coll Educ, Gyongsan 38453, South Korea
基金
新加坡国家研究基金会;
关键词
radio-frequency; microwave; insulin; glucose; real-time; biosensor; diabetes; DEPENDENT DIELECTRIC-PROPERTIES; BLOOD-GLUCOSE; CAVITY PERTURBATION; MICROWAVE RESONATOR; ENZYME-ELECTRODE; RING-RESONATOR; SENSOR; TISSUE; DESIGN; REAGENTLESS;
D O I
10.3390/s21051843
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This review paper focuses on radio-frequency (RF) biosensors for real-time and continuous glucose sensing reported in the literature, including our recent research. Diverse versions of glucose biosensors based on RF devices and circuits are briefly introduced, and their performances are compared. In addition, the limitations of the developed RF glucose biosensors are discussed. Finally, we present perspectives on state-of-art RF biosensing chips for point-of-care diagnosis and describe their future challenges.
引用
收藏
页码:1 / 21
页数:22
相关论文
共 124 条
[21]  
Chen L. F., 2004, MICROWAVE ELECT MEAS
[22]   Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor [J].
Choi, Heungjae ;
Naylon, Jack ;
Luzio, Steve ;
Beutler, Jan ;
Birchall, James ;
Martin, Chris ;
Porch, Adrian .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2015, 63 (10) :3016-3025
[23]   Microwave-Based Microfluidic Sensor for Non-Destructive and Quantitative Glucose Monitoring in Aqueous Solution [J].
Chretiennot, Thomas ;
Dubuc, David ;
Grenier, Katia .
SENSORS, 2016, 16 (10)
[24]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[25]   Towards glucose biofuel cells implanted in human body for powering artificial organs: Review [J].
Cosnier, Serge ;
Le Goff, Alan ;
Holzinger, Michael .
ELECTROCHEMISTRY COMMUNICATIONS, 2014, 38 :19-23
[26]  
Costanzo S, 2017, PROC EUR CONF ANTENN, P661, DOI 10.23919/EuCAP.2017.7928578
[27]  
Deshmukh VV, 2020, PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND CONTROL SYSTEMS (ICICCS 2020), P720, DOI [10.1109/ICICCS48265.2020.9120873, 10.1109/iciccs48265.2020.9120873]
[28]   Blood glucose monitoring using microwave cavity perturbation [J].
Dobson, R. ;
Wu, R. ;
Callaghan, P. .
ELECTRONICS LETTERS, 2012, 48 (15) :905-906
[29]  
Ebrahimi Amir, 2015, 2015 IEEE 15th Mediterranean Microwave Symposium (MMS), DOI 10.1109/MMS.2015.7375441
[30]   Microwave reflective biosensor for glucose level detection in aqueous solutions [J].
Ebrahimi, Amir ;
Scott, James ;
Ghorbani, Kamran .
SENSORS AND ACTUATORS A-PHYSICAL, 2020, 301