DEVELOPMENT OF A VALIDATED METHOD FOR SIMULTANEOUS QUANTIFICATION OF CLARITHROMYCIN AND LEVOFLOXACIN BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTOR

被引:2
|
作者
Ijaz, Qazi Amir [1 ]
Abbas, Nasir [1 ]
Latif, Sumera [2 ]
Hussain, Amjad [1 ]
Arshad, Muhammad Sohail [3 ]
Ali, Ejaz [1 ]
Rashid, Memoona [1 ]
Sohail, Kashif [4 ]
Riaz, Sohail [4 ]
Bukhari, Nadeem Irfan [1 ]
机构
[1] Univ Punjab, Univ Coll Pharm, Lahore, Pakistan
[2] Lahore Coll Women Univ, Fac Pharmaceut & Allied Hlth Sci, Inst Pharm, Lahore, Pakistan
[3] Bahauddin Zakariya Univ, Dept Pharmaceut, Multan, Pakistan
[4] Mirpur Univ Sci & Technol, Akron Coll Pharm, Mirpur, AJ&K, Pakistan
来源
ACTA POLONIAE PHARMACEUTICA | 2020年 / 77卷 / 06期
关键词
clarithromycin; levofloxacin; high-performance liquid chromatography; diode array detector; validation; simultaneous quantification; HPLC METHOD; IN-VITRO; RP-HPLC; PHARMACOKINETICS; COMBINATIONS; IMPURITIES; BULK;
D O I
10.32383/appdr/131197
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This study aims at the development of a validated reverse phase-high performance liquid chromatography (RP-HPLC) method for the simultaneous quantification of levofloxacin (LVX) and clarithromycin (CAM). Eclipse X DB C18 column (5 mu m, 4.6 x250 mm) was used as a stationary phase, and monobasic potassium phosphate (KH2PO4) buffer (0.035 M): acetonitrile (75 : 25) was used as an isocratic mobile phase. The pH of the mobile phase was adjusted to 4.5 with the help of diluted orthophosphoric acid. The diode array detector (DAD) was operated at 205 nm and 294 nm for the detection of CAM and LVX, respectively. Limit of detection (LOD) values for CAM and LVX were 1.22 mu g/mL and 0.79 mu g/mL, respectively. Limit of quantification(LOQ) values for CAM and LVX were 4.08 mu g/mL and 2.64 mu g/mL, respectively. The method was precise as% relative standard deviation (% RSD) values were less than 2% for all types of precision. This method was successfully applied to determine the percentage contents of both drugs in the pharmaceutical preparation.
引用
收藏
页码:841 / 847
页数:7
相关论文
共 50 条
  • [31] Quantification of Polyacetylenes in Apiaceous Plants by High-Performance Liquid Chromatography Coupled with Diode Array Detection
    Kramer, Maike
    Muehleis, Andrea
    Conrad, Juergen
    Leitenberger, Martin
    Beifuss, Uwe
    Carle, Reinhold
    Kammerer, Dietmar R.
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION C-A JOURNAL OF BIOSCIENCES, 2011, 66 (7-8): : 319 - 327
  • [32] Curcuminoid’s Content and Fingerprint Analysis for Authentication and Discrimination of Curcuma xanthorrhiza from Curcuma longa by High-Performance Liquid Chromatography-Diode Array Detector
    Mohamad Rafi
    Laela Wulansari
    Rudi Heryanto
    Latifah Kosim Darusman
    Lee Wah Lim
    Toyohide Takeuchi
    Food Analytical Methods, 2015, 8 : 2185 - 2193
  • [33] Innovative High-Performance Liquid Chromatography with a Diode Array Detector Method for the Simultaneous Analysis of Thiamine, Folic Acid, and Niacin in Fortified Rice for Monitoring in Fortification Programs: Development and Validation
    Fernandez-Sanchez, Oscar
    Rodriguez-Salazar, Massiel
    Quiros-Fallas, Andrea
    Sanchez-Chinchilla, Luis
    Alfaro-Calvo, Thelma
    ACS FOOD SCIENCE & TECHNOLOGY, 2025, 5 (02): : 608 - 620
  • [34] Rapid, simple and accurate liquid chromatography-diode array detection validated method for the determination of dipyrone in solid and liquid dosage forms
    Senyuva, HZ
    Aksahin, I
    Ozcan, S
    Kabasakal, BV
    ANALYTICA CHIMICA ACTA, 2005, 547 (01) : 73 - 77
  • [35] Development and application of a high-performance liquid chromatography diode-array detection (HPLC-DAD) method for the simultaneous quantification of phenolic compounds in the aerial part of Glehnia littoralis
    Park, Yun Ji
    Choi, Yeong Bin
    Oh, Sang-Bin
    Moon, Jinyoung
    Truong, To Quyen
    Huynh, Phuong Kim
    Kim, Sang Min
    APPLIED BIOLOGICAL CHEMISTRY, 2024, 67 (01)
  • [36] Simultaneous determination of atorvastatin and valsartan in human plasma by solid-based disperser liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection
    Farajzadeh, Mir Ali
    Khorram, Parisa
    Pazhohan, Azar
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1017 : 62 - 69
  • [37] Concepts and principles for new rapid simple liquid chromatography method for quantification of antioxidants resveratrol, vitamin E, and coenzyme Q10 in capsules with high-performance liquid chromatography with a photo-diode array detector
    Piponski, Marjan
    Topkoska-Naumoska, Marina
    Slaveska-Spirevska, Irena
    Miloshevska, Martina
    Korobko, Dmytro
    Symaniuk, Tetiana
    Okeke, Vanessa Chichebem
    Zimych, Andrii
    Logoyda, Liliya
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (01)
  • [38] Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants
    Farajzadeh, Mir Ali
    Bahram, Morteza
    Jonsson, Jan Ake
    ANALYTICA CHIMICA ACTA, 2007, 591 (01) : 69 - 79
  • [39] Simultaneous determination of nine ginsenosides in functional foods by high performance liquid chromatography with diode array detector detection
    Shi, Ying
    Sun, Chengjun
    Zheng, Bo
    Li, Yang
    Wang, Yuan
    FOOD CHEMISTRY, 2010, 123 (04) : 1322 - 1327
  • [40] A Validated high Performance Liquid Chromatographic Method for the Quantification of Favipiravir by PDA Detector
    Nadendla, Ramarao
    Patchala, Abhinandana
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2021, 11 (02): : P181 - P188