DEVELOPMENT OF A VALIDATED METHOD FOR SIMULTANEOUS QUANTIFICATION OF CLARITHROMYCIN AND LEVOFLOXACIN BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTOR

被引:2
|
作者
Ijaz, Qazi Amir [1 ]
Abbas, Nasir [1 ]
Latif, Sumera [2 ]
Hussain, Amjad [1 ]
Arshad, Muhammad Sohail [3 ]
Ali, Ejaz [1 ]
Rashid, Memoona [1 ]
Sohail, Kashif [4 ]
Riaz, Sohail [4 ]
Bukhari, Nadeem Irfan [1 ]
机构
[1] Univ Punjab, Univ Coll Pharm, Lahore, Pakistan
[2] Lahore Coll Women Univ, Fac Pharmaceut & Allied Hlth Sci, Inst Pharm, Lahore, Pakistan
[3] Bahauddin Zakariya Univ, Dept Pharmaceut, Multan, Pakistan
[4] Mirpur Univ Sci & Technol, Akron Coll Pharm, Mirpur, AJ&K, Pakistan
来源
ACTA POLONIAE PHARMACEUTICA | 2020年 / 77卷 / 06期
关键词
clarithromycin; levofloxacin; high-performance liquid chromatography; diode array detector; validation; simultaneous quantification; HPLC METHOD; IN-VITRO; RP-HPLC; PHARMACOKINETICS; COMBINATIONS; IMPURITIES; BULK;
D O I
10.32383/appdr/131197
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This study aims at the development of a validated reverse phase-high performance liquid chromatography (RP-HPLC) method for the simultaneous quantification of levofloxacin (LVX) and clarithromycin (CAM). Eclipse X DB C18 column (5 mu m, 4.6 x250 mm) was used as a stationary phase, and monobasic potassium phosphate (KH2PO4) buffer (0.035 M): acetonitrile (75 : 25) was used as an isocratic mobile phase. The pH of the mobile phase was adjusted to 4.5 with the help of diluted orthophosphoric acid. The diode array detector (DAD) was operated at 205 nm and 294 nm for the detection of CAM and LVX, respectively. Limit of detection (LOD) values for CAM and LVX were 1.22 mu g/mL and 0.79 mu g/mL, respectively. Limit of quantification(LOQ) values for CAM and LVX were 4.08 mu g/mL and 2.64 mu g/mL, respectively. The method was precise as% relative standard deviation (% RSD) values were less than 2% for all types of precision. This method was successfully applied to determine the percentage contents of both drugs in the pharmaceutical preparation.
引用
收藏
页码:841 / 847
页数:7
相关论文
共 50 条
  • [21] Validated reversed phase-high performance liquid chromatography-diode array detector method for the quantitation of Rutin, a natural immunostimulant for improving survival in aquaculture practice, in toonea sinensis folium
    Shen, Yuping
    Yin, Huawu
    Chen, Bin
    Xia, Guohua
    Yang, Huan
    Jia, Xiaobin
    PHARMACOGNOSY MAGAZINE, 2012, 8 (29) : 49 - 53
  • [22] A Fast and Validated Method for the Determination of Malondialdehyde in Fish Liver Using High-Performance Liquid Chromatography with a Photodiode Array Detector
    Faizan, Mohammad
    Esatbeyoglu, Tuba
    Bayram, Banu
    Rimbach, Gerald
    JOURNAL OF FOOD SCIENCE, 2014, 79 (04) : C484 - C488
  • [23] FAST AND SIMPLE METHOD FOR SIMULTANEOUS DETERMINATION OF BENZOIC ACID AND ACESULFAME-K IN SOFT DRINKS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTOR: METHOD VALIDATION AND UNCERTAINTY EVALUATION
    Putri, Dillani
    Aristiawan, Yosi
    Aryana, Nurhani
    Styarini, Dyah
    PERIODICO TCHE QUIMICA, 2018, 15 (29): : 96 - 105
  • [24] Determination of alkenes in cracking products by normal-phase high-performance liquid chromatography-diode array detection
    Tomic, Tatjana
    Babic, Sandra
    Nasipak, Nada Uzorinac
    Ruszkowski, Maja Fabulic
    Skrobonja, Livijana
    Kastelan-Macan, Marija
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) : 3819 - 3824
  • [25] Determination of triazines and N-methylcarbamate pesticides in water by high-performance liquid chromatography-diode array detection
    Topuz, S
    Alpertunga, B
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (09) : 787 - 795
  • [26] Quantification of residual nitrite and nitrate in ham by reverse-phase high performance liquid chromatography/diode array detector
    Ferreira, I. M. P. L. V. O.
    Silva, S.
    TALANTA, 2008, 74 (05) : 1598 - 1602
  • [27] Development and application of a high-performance liquid chromatography diode-array detection (HPLC–DAD) method for the simultaneous quantification of phenolic compounds in the aerial part of Glehnia littoralis
    Yun Ji Park
    Yeong Bin Choi
    Sang-Bin Oh
    Jinyoung Moon
    To Quyen Truong
    Phuong Kim Huynh
    Sang Min Kim
    Applied Biological Chemistry, 67
  • [28] High Performance Liquid Chromatography-Diode Array Detector Method for Benznidazole Quantitation in Lipid Based and Self Assembling Cyclodextrins Drug Delivery Systems
    Streck, Leticia
    Doro, Polyanne N. de M.
    Fernandes-Pedrosa, Matheus F.
    da Silva-Junior, Arnobio A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (07) : 922 - 929
  • [29] Simultaneous Determination of B Group Vitamins in Supplemented Food Products by High Performance Liquid Chromatography-Diode Array Detection
    Suh, Joon Hyuk
    Yang, Dong-Hyug
    Lee, Byung Kyu
    Eom, Han Young
    Kim, Unyong
    Kim, Junghyun
    Lee, Hyeyeon
    Han, Sang Beom
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (08) : 2648 - 2656
  • [30] Simultaneous measurement of pazufloxacin, ciprofloxacin, and levofloxacin in human serum by high-performance liquid chromatography with fluorescence detection
    Watabe, Satoshi
    Yokoyama, Yoshiaki
    Nakazawa, Kazuyuki
    Shinozaki, Kimikazu
    Hiraoka, Rika
    Takeshita, Kei
    Suzuki, Yukio
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1555 - 1561