A plastic scintillation dosimeter for high dose rate brachytherapy

被引:108
作者
Lambert, J. [1 ]
McKenzie, D. R.
Law, S.
Elsey, J.
Suchowerska, N.
机构
[1] Univ Sydney, Sch Phys, Sydney, NSW 2006, Australia
[2] Royal Prince Alfred Hosp, Dept Radiat Oncol, Camperdown, NSW 2050, Australia
[3] Univ Sydney, Opt Fibre Technol Ctr, Eveleigh, NSW 1430, Australia
[4] Bandwidth Foundry Pty Ltd, Eveleigh, NSW 1430, Australia
关键词
D O I
10.1088/0031-9155/51/21/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vivo dose verification in brachytherapy requires a small insertable dosimeter with a real-time readout capability. Fibre optic scintillation dosimeters, consisting of a plastic scintillator coupled to an optical fibre, are one of the most promising dosimeters for this application. We have developed two sizes of the BrachyFOD (TM) scintillation dosimeter which have external diameters of 2.2 mm and 1 mm and have determined their important dosimetric characteristics ( depth dose relation, angular dependence, temperature dependence, energy dependence). We have shown that the background signal created by Cerenkov and fibre fluorescence does not significantly affect the performance in most clinical geometries using an Ir-192 source from an HDR brachytherapy unit. The dosimeter design enables readout at less than 0.5 s intervals. The BrachyFOD (TM) satisfies the need for a real-time in vivo brachytherapy dosimeter.
引用
收藏
页码:5505 / 5516
页数:12
相关论文
共 21 条
[1]   Measurement accuracy and Cerenkov removal for high performance, high spatial resolution scintillation dosimetry [J].
Archambault, L ;
Beddar, AS ;
Gingras, L ;
Roy, R ;
Beaulieu, L .
MEDICAL PHYSICS, 2006, 33 (01) :128-135
[2]   Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators [J].
Archambault, L ;
Arsenault, J ;
Gingras, L ;
Beddar, AS ;
Roy, R ;
Beaulieu, L .
MEDICAL PHYSICS, 2005, 32 (07) :2271-2278
[3]   A high-precision, high-resolution and fast dosimetry system for beta sources applied in cardiovascular brachytherapy [J].
Bambynek, M ;
Flühs, D ;
Quast, U ;
Wegener, D ;
Soares, CG .
MEDICAL PHYSICS, 2000, 27 (04) :662-667
[4]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[5]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[6]   Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators [J].
Beddar, AS ;
Briere, TM ;
Mourtada, FA ;
Vassiliev, ON ;
Liu, HH ;
Mohan, R .
MEDICAL PHYSICS, 2005, 32 (05) :1265-1269
[7]   A temporal method of avoiding the Cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams [J].
Clift, MA ;
Johnston, PN ;
Webb, DV .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (08) :1421-1433
[8]   Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams [J].
Clift, MA ;
Sutton, RA ;
Webb, DV .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05) :1165-1182
[9]   OPTICAL FILTERING AND SPECTRAL MEASUREMENTS OF RADIATION-INDUCED LIGHT IN PLASTIC SCINTILLATION DOSIMETRY [J].
DEBOER, SF ;
BEDDAR, AS ;
RAWLINSON, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (07) :945-958
[10]  
Fluhs D, 1996, MED PHYS, V23, P427, DOI 10.1118/1.597736