Towards automated, miniaturized and solvent-free sample preparation methods

被引:14
作者
David, Frank
Van Hoeck, Els
Sandra, Pat
机构
[1] Res Inst Chromatog, B-8500 Kortrijk, Belgium
[2] Univ Ghent, Organ Chem Lab, B-9000 Ghent, Belgium
关键词
D O I
10.1007/s00216-006-0721-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The automated, miniaturized, and solvent-free sample preparation method for determination of organic compounds in a solute-type combination matrix is discussed. The various characteristics of sample preparation methods include automation, miniaturization, and online and solventless sample preparation with high-throughput capability. These characteristics provide intelligent autosamples enabling the addition of internal solvent standards, solvents with increased sensitivity of detection, online hyphenation of sample preparation, and separation and detection of samples for parallel batch operations. The air monitoring of gaseous samples provide concentration of the analytes on an adsorbent or sorbent, followed by thermal desorption replacing classical adsorption followed by liquid desorption. The miniaturized extraction method using pressurized liquid extraction (PLE) or superheated water extraction, extracts small solvent sample amounts with a limited amount of organic solvent or water.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 8 条
[1]   Sorptive sample preparation - a review [J].
Baltussen, E ;
Cramers, CA ;
Sandra, PJF .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (1-2) :3-22
[2]   Analysis of off-flavors in the aquatic environment by stir bar sorptive extraction-thermal desorption-capillary GC/MS/olfactometry [J].
Benanou, D ;
Acobas, F ;
de Roubin, MR ;
Sandra, FDP .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (01) :69-77
[3]   Evaluation of ultra performance liquid chromatography -: Part I.: Possibilities and limitations [J].
de Villiers, Andre ;
Lestremau, Francois ;
Szucs, Roman ;
Gelebart, Sylvie ;
David, Frank ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) :60-69
[4]   Recent advances in matrix solid-phase dispersion [J].
Kristenson, EM ;
Ramos, L ;
Brinkman, UAT .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (02) :96-111
[5]   High-efficiency liquid chromatography on conventional columns and instrumentation by using temperature as a variable I.: Experiments with 25 cm x 4.6 mm ID, 5 μm ODS columns [J].
Lestremau, F ;
Cooper, A ;
Szucs, R ;
David, F ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1109 (02) :191-196
[6]   Current use of pressurised liquid extraction and subcritical water extraction in environmental analysis [J].
Ramos, L ;
Kristenson, EM ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) :3-29
[7]  
VANHOECK E, 2006, 29 ISCC MAY 29 JUN 2
[8]  
WAUTERS E, 2006, UNPUB