Development of a Paste-type Certified Reference Material of Tomato for Elemental Analysis: Certification and Long-term Stability Study

被引:9
|
作者
Choi, Jiha [1 ]
Hwang, Euijin [1 ]
Yim, Yong-Hyeon [1 ]
Jo, Hang Mi [1 ]
Lim, Youngran [1 ]
Kim, Tae Kyu [2 ]
Lee, Kyoung-Seok [1 ]
机构
[1] Korea Res Inst Stand & Sci KRISS, Ctr Inorgan Anal, Daejeon 34113, South Korea
[2] Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
来源
BULLETIN OF THE KOREAN CHEMICAL SOCIETY | 2017年 / 38卷 / 02期
关键词
Tomato paste; Certified reference material; Stability; Isotope dilution ICP-MS; Elemental analysis; DIETARY-INTAKE; CANNED FOOD; TIN; CORROSION;
D O I
10.1002/bkcs.11066
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A paste-type certified reference material (CRM) of tomato was developed for accurate elemental analysis of canned foods. Accurate mass fractions of cadmium (Cd), lead (Pb), and tin (Sn) in the tomato paste CRM were determined by isotope dilution inductively coupled plasma mass spectrometry. The certified values and their expanded uncertainties (k= 2 at approximately 95% level of confidence) for Cd, Pb, and Sn were (0.297 +/- 0.015) mg/ kg, (0.213 +/- 0.010) mg/ kg, and (221.2 +/- 9.5) mg/ kg, respectively. Homogeneity of the CRM was 0.3%, 1.8%, and 0.2% for Cd, Pb, and Sn, respectively, which were estimated using the relative standard deviation of the measurement results of 10 separate sample bottles from one batch of the CRM. Major contributions to the measurement uncertainties for Cd and Sn were the uncertainties of the isotope ratios of Cd and Sn in the sample and the elemental standards. The uncertainty for Pb was mainly affected by sample homogeneity. Stability tests were conducted for 6 and 12 months at -20, 4, and 25 degrees C, and the storage temperature for the CRM was determined to be -20 degrees C. To investigate term storage, the mass fractions of Cd, Pd, and Sn in the CRM were re-determinedafter storage for 7 years. The results were in good agreement with the certified results implying that this CRM is stable for 7 years if kept at an appropriate storage condition with vacuum packaging the amber glass bottles in aluminum-coated polymer bag.
引用
收藏
页码:211 / 218
页数:8
相关论文
共 22 条
  • [1] Development of a Nutritional Supplement Certified Reference Material for Elemental Analysis
    Lee, Jong Wha
    Heo, Sung Woo
    Kim, Hwijin
    Lim, Youngran
    Lee, Kyoung-Seok
    Yim, Yong-Hyeon
    MASS SPECTROMETRY LETTERS, 2018, 9 (04) : 105 - 109
  • [2] Development of a lyophilized soybean paste certified reference material for the analysis of ochratoxin A
    Ahn, Seonghee
    Lee, Suyoung
    Lee, Sunyoung
    Kim, Byungjoo
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2016, 52 : 68 - 73
  • [3] Long-term stability test of elemental content in new environmental certified reference material candidates using ICP OES and ICP-SFMS
    Idris, Abubakr M.
    Alnajjar, Ahmed O.
    Alkhuraiji, Turki S.
    Fawy, Khaled F.
    TOXIN REVIEWS, 2021, 40 (04) : 645 - 653
  • [4] Development of a Certified Reference Material (NMIJ CRM 7203-a) for Elemental Analysis of Tap Water
    Zhu, Yanbei
    Narukawa, Tomohiro
    Inagaki, Kazumi
    Miyashita, Shin-ichi
    Kuroiwa, Takayoshi
    Ariga, Tomoko
    Kudo, Izumi
    Koguchi, Masae
    Heo, Sung Woo
    Suh, Jung Ki
    Lee, Kyoung-Seok
    Yim, Yong-Hyeon
    Lim, Youngran
    ANALYTICAL SCIENCES, 2017, 33 (03) : 403 - 407
  • [5] Development of a Certified Reference Material (NMIJ CRM 7203-a) for Elemental Analysis of Tap Water
    Yanbei Zhu
    Tomohiro Narukawa
    Kazumi Inagaki
    Shin-ichi Miyashita
    Takayoshi Kuroiwa
    Tomoko Ariga
    Izumi Kudo
    Masae Koguchi
    Sung Woo Heo
    Jung Ki Suh
    Kyoung-Seok Lee
    Yong-Hyeon Yim
    Youngran Lim
    Analytical Sciences, 2017, 33 : 403 - 407
  • [6] Short- and long-term stability of electrolytic conductivity certified reference materials
    L. Deleebeeck
    J. Avnskjold
    A. Snedden
    Accreditation and Quality Assurance, 2020, 25 : 127 - 138
  • [7] Development of a coffee bean certified reference material (KRISS CRM 108-10-023) for elemental analysis
    Jong Wha Lee
    Myung Chul Lim
    Youngran Lim
    Gizachew Betru Tegegn
    Kyoung-Seok Lee
    Analytical and Bioanalytical Chemistry, 2024, 416 : 475 - 486
  • [8] Short- and long-term stability of electrolytic conductivity certified reference materials
    Deleebeeck, L.
    Avnskjold, J.
    Snedden, A.
    ACCREDITATION AND QUALITY ASSURANCE, 2020, 25 (02) : 127 - 138
  • [9] Development of a coffee bean certified reference material (KRISS CRM 108-10-023) for elemental analysis
    Lee, Jong Wha
    Lim, Myung Chul
    Lim, Youngran
    Tegegn, Gizachew Betru
    Lee, Kyoung-Seok
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (03) : 827 - 837
  • [10] Development of a Certified Reference Material (NMIJ CRM 7202-c) for Trace Elemental Analysis of River Water
    Ariga, Tomoko
    Narukawa, Tomohiro
    Zhu, Yanbei
    Miyashita, Shin-ichi
    Kudo, Izumi
    Kocuchi, Masae
    Inagaki, Kazumi
    BUNSEKI KAGAKU, 2020, 69 (1-2) : 11 - 23