Flow injection determination of thyroxine in pharmaceutical preparations using tris(2,2′-bipyridyl)ruthenium(III)-NADH chemiluminescence detection

被引:18
作者
Waseem, Amir [1 ]
Yaqoob, Mohammad [1 ]
Nabi, Abdul [1 ]
机构
[1] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
flow injection analysis; chemiluminescence; thyroxine; NADH; pharmaceuticals;
D O I
10.1016/j.talanta.2006.03.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection (H) method is reported for the determination of thyroxine based on its enhancement of chemiluminescence (CL) from the Ru(bpy)(3) (3+)-NADH system. The calibration graph was linear over the range 2.0-10 x 10(-8) mol L-1 (r(2) = 0.9989) with relative standard deviations (R.S.D.) in the range 2.0-4.5% (n = 4). The limit of detection (3 sigma blank) was 1.0 x 10(-9) mol L-1 with sample throughput of 120 h-1. The effect of some organic compounds, anions and cations were studied for L-thyroxine determination. The method was applied to pharmaceutical preparations and the results obtained were in reasonable agreement with the amount labeled. The method was statistically compared with the results obtained by RIA; no significant disagreement at 95% confidence limit was observed. A calibration graph of NADH over the range 1.3 x 10(-8)-1.3 x 10(-6) mol L-1 was also established (r(2) = 0.9992) with R.S.D. in the range 1.0-3.5% (n = 4). The limit of detection (3 sigma) was 1.0 x 10(-10) mol L-1 NADH. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 61
页数:6
相关论文
共 50 条
[21]   Tris(2,2-bipyridyl)ruthenium (II) chemiluminescence in a microflow injection system for codeine determination [J].
Greenway, GM ;
Nelstrop, LJ ;
Port, SN .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :43-50
[22]   Determination of glyphosate and related compounds using HPLC with tris(2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence detection [J].
Ridlen, JS ;
Klopf, GJ ;
Nieman, TA .
ANALYTICA CHIMICA ACTA, 1997, 341 (2-3) :195-204
[23]   Selective determination of acenaphthylene by flow injection analysis with tris(2,2′-bipyridine)ruthenium(II) chemiluminescence detection [J].
Li, Ming ;
Lee, Sang Hak .
TALANTA, 2007, 74 (02) :265-270
[24]   Determination of total calcium in plasma by flow injection analysis with tris(2,2′-bipyridyl)ruthenium(II) electrochemiluminescent detection [J].
Shi, Lihong ;
Liu, Xiaoqing ;
Li, Haijuan ;
Xu, Guobao .
ELECTROANALYSIS, 2006, 18 (16) :1584-1589
[25]   Flow-Injection Chemiluminescence Determination of Aspartic Acid in Tea Leaves Using Tris (2,2′-bipyridyl) Ruthenium (II)–Ce(IV) System [J].
Sang Hak Lee ;
Chi Wan Jeon ;
Saikh Mohammad Wabaidur .
Journal of Fluorescence, 2008, 18 :655-660
[26]   Flow-injection chemiluminescence determination of aspartic acid in tea leaves using tris (2,2′-bipyridyl) ruthenium (II)-Ce(IV) system [J].
Lee, Sang Hak ;
Jeon, Chi Wan ;
Wabaidur, Saikh Mohammad .
JOURNAL OF FLUORESCENCE, 2008, 18 (3-4) :655-660
[27]   Selective Detection of Hydroxyl Radical Scavenging Capacity Based on Electrogenerated Chemiluminescence Detection Using Tris(2,2′-bipyridine)ruthenium(III) by Flow Injection Analysis [J].
Nobushi, Yasuhito ;
Uchikura, Kazuo .
CHEMICAL & PHARMACEUTICAL BULLETIN, 2010, 58 (01) :117-120
[28]   Coreactants of tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence [J].
Yuan, Yali ;
Han, Shuang ;
Hu, Lianzhe ;
Parveen, Saima ;
Xu, Guobao .
ELECTROCHIMICA ACTA, 2012, 82 :484-492
[29]   Determination of thyroxine in pharmaceuticals using flow injection with luminol chemiluminescence inhibition detection [J].
Waseem, Amir ;
Yaqoob, Mohammad ;
Nabi, Abdul .
LUMINESCENCE, 2006, 21 (03) :174-178
[30]   Chemiluminescence Determination of Thiourea Using Tris(2,2′-bipyridyl)ruthenium(II)–KMnO4 System [J].
Zhike He ;
Fengwu Wu ;
Hui Meng ;
Liansheng Ling ;
Liangjie Yuan ;
Qingyao Luo ;
Yun’e Zeng .
Analytical Sciences, 1999, 15 :381-383