Continuous Non-Invasive Arterial Pressure Technique Improves Patient Monitoring during Interventional Endoscopy

被引:0
|
作者
Siebig, Sylvia [1 ]
Rockmann, Felix [1 ]
Sabel, Karl [1 ]
Zuber-Jerger, Ina [1 ]
Dierkes, Christine [1 ]
Bruennler, Tanja [1 ]
Wrede, Christian E. [1 ]
机构
[1] Univ Regensburg, Dept Internal Med 1, D-93042 Regensburg, Germany
来源
关键词
continuous non-invasive blood pressure; procedural sedation; endoscopy; cardiovascular monitoring; hypotension; GASTROINTESTINAL ENDOSCOPY; TRAINED NONANESTHESIOLOGISTS; PROPOFOL; SEDATION; PROTOCOL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Close monitoring of arterial blood pressure (BP) is a central part of cardiovascular surveillance of patients at risk for hypotension. Therefore, patients undergoing diagnostic and therapeutic procedures with the use of sedating agents are monitored by discontinuous non-invasive BP measurement (NIBP). Continuous non-invasive BP monitoring based on vascular unloading technique (CNAP (R), CN Systems, Graz) may improve patient safety in those settings. We investigated if this new technique improved monitoring of patients undergoing interventional endoscopy. Methods: 40 patients undergoing interventional endoscopy between April and December 2007 were prospectively studied with CNAP (R) in addition to standard monitoring (NIBP, ECG and oxygen saturation). All monitoring values were extracted from the surveillance network at one-second intervals, and clinical parameters were documented. The variance of CNAP (R) values were calculated for every interval between two NIBP measurements. Results: 2660 minutes of monitoring were recorded (mean 60.1 +/- 34.4 min/patient). All patients were analgosedated with midazolam and pethidine, and 24/40 had propofol infusion (mean 90.9 +/- 70.3 mg). The mean arterial pressure for CNAP (R) was 102.4 +/- 21.2 mmHg and 106.8 +/- 24.8 mmHg for NIBP. Based on the first NIBP value in an interval between two NIBP measurements, BP values determined by CNAP (R) showed a maximum increase of 30.8 +/- 21.7% and a maximum decrease of 22.4 +/- 28.3% (mean of all intervals). Discussion: Conventional intermittent blood pressure monitoring of patients receiving sedating agents failed to detect fast changes in BP. The new technique CNAP (R) improved the detection of rapid BP changes, and may contribute to a better patient safety for those undergoing interventional procedures.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [1] Non-invasive continuous blood pressure monitoring of tachycardic episodes during interventional electrophysiology
    Maggi, Roberto
    Viscardi, Valentina
    Furukawa, Toshiyuki
    Brignole, Michele
    EUROPACE, 2010, 12 (11): : 1616 - 1622
  • [2] A new continuous and non-invasive monitoring technique for arterial pressure (AP) in chronic hemodialysis (HD).
    Mancini, E
    Mambelli, E
    Canova, C
    Santoro, A
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 488A - 488A
  • [3] A continuous and non-invasive arterial pressure monitoring system in dialysis patients
    Mambelli, Emanuele
    Mancini, Elena
    Santoro, Antonio
    NEPHRON CLINICAL PRACTICE, 2007, 107 (04): : C170 - C176
  • [4] CNAP - EVOLUTION OF CONTINUOUS NON-INVASIVE ARTERIAL BLOOD PRESSURE MONITORING
    Fortin, J.
    Wellisch, A.
    Maier, K.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [5] CNAP - EVOLUTION OF CONTINUOUS NON-INVASIVE ARTERIAL BLOOD PRESSURE MONITORING
    Fortin, J.
    Wellisch, A.
    Maier, K.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [6] Non-invasive arterial pressure monitoring revisited
    Frederic Michard
    Daniel I. Sessler
    Bernd Saugel
    Intensive Care Medicine, 2018, 44 : 2213 - 2215
  • [7] Non-invasive arterial pressure monitoring revisited
    Michard, Frederic
    Sessler, Daniel I.
    Saugel, Bernd
    INTENSIVE CARE MEDICINE, 2018, 44 (12) : 2213 - 2215
  • [8] Wearable Pneumatic Sensor for Non-invasive Continuous Arterial Blood Pressure Monitoring
    Antsiperov, Viacheslav
    Mansurov, Gennady
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING (IWBBIO 2018), PT II, 2019, 10814 : 383 - 394
  • [9] Validation of non-invasive arterial pressure monitoring during carotid endarterectomy
    Heusdens, J. F.
    Lof, S.
    Pennekamp, C. W. A.
    Specken-Welleweerd, J. C.
    de Borst, G. J.
    van Klei, W. A.
    van Wolfswinkel, L.
    Immink, R. V.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (03) : 316 - 323
  • [10] Non-invasive arterial pressure monitoring during liver transplantation.
    Findlay, JY
    Gali, B
    Keegan, MT
    Jankowski, CJ
    Burke, CM
    Plevak, DJ
    LIVER TRANSPLANTATION, 2004, 10 (06) : C2 - C2