Monitoring of haemoglobin oxygen saturation in healthy infants using a new generation pulse oximeter which takes motion artifacts into account

被引:11
作者
Meyts, I
Van Reempts, P
De Boeck, K
机构
[1] Univ Hosp Gasthuisberg, Dept Paediat Pulm, B-3000 Louvain, Belgium
[2] Univ Antwerp Hosp, Dept Paediat, Wilrijk, Belgium
关键词
haemoglobin; infants; oximetry; oxygen saturation;
D O I
10.1007/s00431-002-1089-3
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The aim of this study was to establish normal values for overnight oxygen saturation (SpO(2)) in healthy term infants using an oximeter which takes into account motion artifacts and to compare these to normal values collected with a previous generation oximeter not correcting for motion artifacts. We recorded overnight SpO(2) in 26 term, healthy infants (median age 136 days, range 6-364 days) in the home environment using the Nellcor Symphony N 3000 pulse oximeter with an averaging time of 3 s. A sample rate of 5 s was chosen. Motion artifacts were excluded from the analysis. Data were compared with those from a previous study, using the same inclusion and exclusion criteria with the Oxford Medilog. Median (quartiles) SpO(2) was 98% (97%99%). Median percentage of study time below SpO(2) 94% was 0.2% (0.1%-0.7%); median percentage of study time below SpO(2) 90% was 0.0% (0.0%-0.01%). Median SpO(2) with the Oxford oximeter was 97% (96%98%); percentage of study time below SpO(2) 94% was 8% (2%-14%); percentage of study time below SpO(2) 90% was 2% (0%-4%). These data were compared with the Nellcor Symphony data: differences in median SpO(2) were significant (P<0.05); differences in percentage of time below SpO(2) 94% and 90% were also statistically significant (P<0.001). Conclusion: we established normal values of oxygen saturation in healthy term infants using the Nellcor Symphony 3000 pulse oximeter. Care should be taken in interpreting values obtained with different types of pulse oximeters.
引用
收藏
页码:653 / 655
页数:3
相关论文
共 11 条
  • [1] PULSE OXIMETRY IN PEDIATRIC INTENSIVE-CARE - COMPARISON WITH MEASURED SATURATIONS AND TRANS-CUTANEOUS OXYGEN-TENSION
    FANCONI, S
    DOHERTY, P
    EDMONDS, JF
    BARKER, GA
    BOHN, DJ
    [J]. JOURNAL OF PEDIATRICS, 1985, 107 (03) : 362 - 366
  • [2] Importance of the pulse oximeter averaging time when measuring oxygen desaturation in sleep apnea
    Farré, R
    Montserrat, JM
    Ballester, E
    Hernández, L
    Rotger, M
    Navajas, D
    [J]. SLEEP, 1998, 21 (04) : 386 - 390
  • [3] Home treatment for chronic respiratory failure in children: A prospective study
    Fauroux, B
    Sardet, A
    Foret, D
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (12) : 2062 - 2066
  • [4] PULSE OXIMETRY VERSUS MEASURED ARTERIAL OXYGEN-SATURATION - A COMPARISON OF THE NELLCOR N100 AND THE BIOX-III
    LEBECQUE, P
    SHANGO, P
    STIJNS, M
    VLIERS, A
    COATES, AL
    [J]. PEDIATRIC PULMONOLOGY, 1991, 10 (02) : 132 - 135
  • [5] MOK JYQ, 1986, J PEDIATR-US, V108, P365
  • [6] Uses and abuses of pulse oximetry
    Moyle, JTB
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1996, 74 (01) : 77 - 80
  • [7] Arterial oxygen saturation in healthy term neonates
    Poets, CF
    Stebbens, VA
    Lang, JA
    OBrien, LM
    Boon, AW
    Southall, DP
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 1996, 155 (03) : 219 - 223
  • [8] POETS CF, 1994, PEDIATRICS, V93, P737
  • [9] OXYGEN-SATURATION AND BREATHING PATTERNS IN INFANCY .1. FULL TERM INFANTS IN THE 2ND MONTH OF LIFE
    STEBBENS, VA
    POETS, CF
    ALEXANDER, JR
    ARROWSMITH, WA
    SOUTHALL, DP
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1991, 66 (05) : 569 - 573
  • [10] SATURATION BY PULSE OXIMETRY - COMPARISON OF THE RESULTS OBTAINED BY INSTRUMENTS OF DIFFERENT BRANDS
    THILO, EH
    ANDERSEN, D
    WASSERSTEIN, ML
    SCHMIDT, J
    LUCKEY, D
    [J]. JOURNAL OF PEDIATRICS, 1993, 122 (04) : 620 - 626