Aromatic glycinonitriles and methylamines as pre-column fluorescence derivatization reagents for catecholamines

被引:107
作者
Nohta, H
Yukizawa, T
Ohkura, Y
Yoshimura, M
Ishida, J
Yamaguchi, M
机构
[1] LAB MOL BIOPHOTON,SHIZUOKA 434,JAPAN
[2] KYUSHU UNIV,FAC PHARMACEUT SCI,HIGASHI KU,FUKUOKA 812,JAPAN
[3] DOJINDO LABS,KUMAMOTO 86123,JAPAN
[4] FUKUOKA UNIV,FAC PHARMACEUT SCI,JONAN KU,FUKUOKA 81480,JAPAN
关键词
fluorescence derivatization reagent; aromatic glycinonitrile; aromatic methylamine; catecholamine; liquid chromatography;
D O I
10.1016/S0003-2670(96)00614-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The reactivity of some catecholamines with aromatic glycinonitriles (AGN) (four species) and aromatic methylamines (AMA) (five species) was investigated in detail, to find pre-column fluorescence derivatization reagents for catecholamines. Of the nine reagents tested, 2-phenylglycinonitrile (PGN) and benzylamine (BA) were shown to be the best reagents in terms of selectivity and sensitivity, The reagents react selectively with catecholamines under mild conditions in the presence of ammonium molybdate and sodium periodate for PGN and potassium hexacyanoferrate(III) for BA to give fluorescent derivatives. The derivatives of four catecholamines (epinephrine (E), norepinephrine (NE), dopamine (DA) and isoproterenol (IF)) could be separated within 13 min by reversed-phase liquid chromatography with isocratic elution and measured fluorimetrically. The detection limits (signal-to-noise ratio=3) are in the range 5.2-11.0 fmol for PGN and 1.6-100 fmol for BA in a 50 mu l injection volume. The liquid chromatographic (LC) methods with PGN and BA were successfully applied to the determination of some catecholamines in human urine.
引用
收藏
页码:233 / 240
页数:8
相关论文
共 15 条
[1]   DETERMINATION OF FEMTOMOLE CONCENTRATIONS OF CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION [J].
HIGASHIDATE, S ;
IMAI, K .
ANALYST, 1992, 117 (12) :1863-1868
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF 5-HYDROXYINDOLES BY POSTCOLUMN FLUORESCENCE DERIVATIZATION [J].
ISHIDA, J ;
IIZUKA, R ;
YAMAGUCHI, M .
ANALYST, 1993, 118 (02) :165-169
[3]   SPECTROFLUORIMETRIC DETERMINATION OF 5-HYDROXYINDOLES WITH BENZYLAMINE OR 3,4-DIMETHOXYBENZYLAMINE AS A SELECTIVE FLUOROGENIC REAGENT [J].
ISHIDA, J ;
YAMAGUCHI, M ;
NAKAMURA, M .
ANALYST, 1991, 116 (03) :301-304
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PLASMA-CATECHOLAMINES USING 1,2-DIPHENYLETHYLENEDIAMINE AS PRECOLUMN FLUORESCENCE DERIVATIZATION REAGENT [J].
MITSUI, A ;
NOHTA, H ;
OHKURA, Y .
JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV) :61-70
[5]  
MITSUI A, 1986, ANAL SCI, V2, P303
[6]   SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY SYSTEM WITH FLUOROMETRIC DETECTION OF 3 URINARY CATECHOLAMINES IN THE SAME RANGE [J].
MORI, K ;
IMAI, K .
ANALYTICAL BIOCHEMISTRY, 1985, 146 (02) :283-286
[7]  
NOHTA H, 1984, BUNSEKI KAGAKU, V33, pE263
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF URINARY CATECHOLAMINES BY DIRECT PRECOLUMN FLUORESCENCE DERIVATIZATION WITH 1,2-DIPHENYLETHYLENEDIAMINE [J].
NOHTA, H ;
MITSUI, A ;
OHKURA, Y .
JOURNAL OF CHROMATOGRAPHY, 1986, 380 (01) :229-231
[9]   FLUORESCENT PRODUCTS OF THE REACTION FOR THE DETERMINATION OF CATECHOLAMINES WITH 1,2-DIPHENYLETHYLENEDIAMINE [J].
NOHTA, H ;
LEE, MK ;
OHKURA, Y .
ANALYTICA CHIMICA ACTA, 1992, 267 (01) :137-139
[10]   SPECTROFLUORIMETRIC DETERMINATION OF CATECHOLAMINES WITH 1,2-DIPHENYLETHYLENEDIAMINE [J].
NOHTA, H ;
MITSUI, A ;
OHKURA, Y .
ANALYTICA CHIMICA ACTA, 1984, 165 (NOV) :171-176